{"title":"AC \u0026 SHORE POWER","description":null,"products":[{"product_id":"victron-anti-islanding-relay-ziehl-voltage-and-fre","title":"Victron Energy - Anti-Islanding relay - Ziehl Voltage and Frequency Relay UFR1001E","description":"\u003ch2\u003eZiehl UFR1001E Voltage and Frequency Relay for Grid-Connected Generation Systems\u003c\/h2\u003e\n\u003ch3\u003eReliable Anti-Islanding Protection for Solar PV and Distributed Energy Resources\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eZiehl UFR1001E\u003c\/strong\u003e is a precision \u003cstrong\u003evoltage and frequency relay\u003c\/strong\u003e engineered to deliver \u003cstrong\u003eanti-islanding protection\u003c\/strong\u003e for \u003cstrong\u003egrid-connected generation systems\u003c\/strong\u003e. It continuously monitors \u003cstrong\u003evoltage and frequency\u003c\/strong\u003e at the point of common coupling, ensuring immediate disconnection when grid parameters fall outside prescribed limits. This is essential for compliance with \u003cstrong\u003eVDE-AR-N 4105:2018-11\u003c\/strong\u003e, \u003cstrong\u003eVDE-AR-N 4110:2018-11\u003c\/strong\u003e, \u003cstrong\u003eG98\u003c\/strong\u003e, \u003cstrong\u003eG99\u003c\/strong\u003e, and \u003cstrong\u003eÖVE\/ÖNORM E 8001-4-712:2009\u003c\/strong\u003e, making it a trusted component in \u003cstrong\u003esolar PV installations\u003c\/strong\u003e, \u003cstrong\u003ecogeneration plants\u003c\/strong\u003e, and other \u003cstrong\u003edistributed energy resources\u003c\/strong\u003e across Australia and Europe.\u003c\/p\u003e\n\u003cp\u003eUnlike generic monitoring relays, the UFR1001E uses \u003cstrong\u003etrue RMS measurement\u003c\/strong\u003e for accurate detection of \u003cstrong\u003eover\/under voltage\u003c\/strong\u003e, \u003cstrong\u003eover\/under frequency\u003c\/strong\u003e, \u003cstrong\u003evector shift\u003c\/strong\u003e, and \u003cstrong\u003erate of change of frequency (ROCOF)\u003c\/strong\u003e. Its \u003cstrong\u003epassive anti-islanding detection\u003c\/strong\u003e (per chapter 6.5.3 and appendix D2) reduces the risk of \u003cstrong\u003eunintentional islanding\u003c\/strong\u003e, protecting both \u003cstrong\u003eutility personnel\u003c\/strong\u003e and \u003cstrong\u003eequipment\u003c\/strong\u003e from \u003cstrong\u003eback-feed hazards\u003c\/strong\u003e. The wide \u003cstrong\u003eauxiliary supply range\u003c\/strong\u003e of \u003cstrong\u003eAC\/DC 24-270V\u003c\/strong\u003e simplifies integration into diverse control circuits, while the \u003cstrong\u003etwo change-over relay contacts\u003c\/strong\u003e provide flexible interfacing with \u003cstrong\u003econtactors\u003c\/strong\u003e or \u003cstrong\u003ecircuit breakers\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive grid monitoring\u003c\/strong\u003e – voltage, frequency, vector shift, and ROCOF in one device\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrue RMS measurement\u003c\/strong\u003e for high accuracy even with distorted waveforms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide auxiliary supply\u003c\/strong\u003e – AC\/DC 24-270V for versatile installation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable setpoints and time delays\u003c\/strong\u003e to match local utility requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClear LCD display and LED indicators\u003c\/strong\u003e for real-time status and diagnostics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact 6 TE DIN rail housing\u003c\/strong\u003e (90 x 105 x 69 mm) for space-efficient panel mounting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP30 \/ IP20 protection\u003c\/strong\u003e suitable for indoor control cabinets\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineered for Compliance and Safety\u003c\/h3\u003e\n\u003cp\u003eMeeting stringent \u003cstrong\u003egrid connection standards\u003c\/strong\u003e is non-negotiable for \u003cstrong\u003esolar installers\u003c\/strong\u003e and \u003cstrong\u003esystem integrators\u003c\/strong\u003e. The UFR1001E is pre-certified to \u003cstrong\u003eVDE-AR-N 4105\u003c\/strong\u003e and \u003cstrong\u003eG99\u003c\/strong\u003e, eliminating guesswork and reducing commissioning time. Its \u003cstrong\u003evector shift detection\u003c\/strong\u003e (\u0026lt;50 ms response) and \u003cstrong\u003eROCOF monitoring\u003c\/strong\u003e provide fast, reliable \u003cstrong\u003eloss of mains\u003c\/strong\u003e detection, a critical requirement for \u003cstrong\u003eembedded generation\u003c\/strong\u003e up to and beyond 30 kW. The \u003cstrong\u003eadjustable hysteresis\u003c\/strong\u003e and \u003cstrong\u003eswitching delays\u003c\/strong\u003e allow fine-tuning to avoid nuisance tripping while maintaining \u003cstrong\u003egrid stability\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eFor larger or three-phase systems, the UFR1001E can be paired with external \u003cstrong\u003econtactors\u003c\/strong\u003e and a \u003cstrong\u003emain circuit breaker\u003c\/strong\u003e. We also offer a pre-assembled \u003cstrong\u003eAnti-Islanding Box 63A\u003c\/strong\u003e (single and three phase) that includes this relay, two in-line 63A contactors, and a main breaker—ready for immediate deployment.\u003c\/p\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolar PV systems\u003c\/strong\u003e – residential, commercial, and industrial grid-tied inverters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery energy storage systems\u003c\/strong\u003e with grid export capability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCogeneration (CHP) plants\u003c\/strong\u003e and backup generators operating in parallel with the grid\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWind and hydro turbines\u003c\/strong\u003e requiring grid synchronisation and protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEV charging infrastructure\u003c\/strong\u003e with vehicle-to-grid (V2G) functionality\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Choose the Ziehl UFR1001E?\u003c\/h3\u003e\n\u003cp\u003eSelecting a \u003cstrong\u003ecertified anti-islanding relay\u003c\/strong\u003e reduces project risk by ensuring \u003cstrong\u003eregulatory compliance\u003c\/strong\u003e from day one. The UFR1001E’s \u003cstrong\u003erobust design\u003c\/strong\u003e and \u003cstrong\u003ewide operating temperature range\u003c\/strong\u003e (-20°C to +55°C) make it suitable for Australian conditions, from coastal installations to inland heat. Its \u003cstrong\u003eDIN rail mounting\u003c\/strong\u003e and \u003cstrong\u003eclear terminal labelling\u003c\/strong\u003e speed up installation, while the \u003cstrong\u003edigital display\u003c\/strong\u003e simplifies commissioning and fault finding.\u003c\/p\u003e\n\u003cp\u003eWith \u003cstrong\u003eproven reliability\u003c\/strong\u003e in thousands of installations worldwide, the UFR1001E is a \u003cstrong\u003efuture-proof choice\u003c\/strong\u003e for \u003cstrong\u003egrid-connected generation\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdd the Ziehl UFR1001E to your project today\u003c\/strong\u003e and ensure your \u003cstrong\u003egrid-tied system\u003c\/strong\u003e meets the latest \u003cstrong\u003eanti-islanding protection\u003c\/strong\u003e requirements with confidence.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eVoltage And Frequency Relay Type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eUFR1001E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003ePart Number\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eS222296\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eComplies With\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eVDE-AR-N 4105:2018-11, VDE-AR-N 4110:2018-11, G98, G99, ÖVE\/ÖNORM E 8001-4-712:2009 and other standards for generators connected to the public grid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eRated Supply Voltage Us\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eAC\/DC 24-270 V, 0\/45...65 Hz, \u0026lt; 5 VA; DC: 20.4...297 V, AC: 20.4...297 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eRelay Output\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e2 change-over contacts; see operating manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMeasurement Phase-Phase\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eAC 15...530 V (\u0026lt; 5 V display: 0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eSetting Range Phase-Phase\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eAC 15...520 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMeasuring Voltage Phase-Neutral\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eAC 10...310 V (\u0026lt; 5 V display: 0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eSetting Range Phase-Neutral\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eAC 15...300 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMeasurement Method\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eTrue RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eVoltage Hysteresis\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eAdjustable 1.0...180 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eVoltage Measurement Accuracy\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eWith neutral: ±0.6% of measured value; without neutral: ±0.8% of measured value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eFrequency Measurement Range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e40...70 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eFrequency Setting Range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e45.00...65.00 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eFrequency Hysteresis\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e0.05...10.00 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eFrequency Measurement Accuracy\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e± 0.04 Hz ± 1 digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eVector-Shift Setting Range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e2.0...65.0°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eROCOF (df\/dt) Setting Range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e0.100...5.000 Hz\/s, 4...50 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eVoltage Switching-Delay (dAL)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eAdjustable 0.05 (± 15 ms)...300.0 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eVoltage Switching-Back-Delay (doF)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eAdjustable 0 (approx. 200 ms)...6.000 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eFrequency Switching-Delay (dAL)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eAdjustable 0.05 (± 15 ms)...300.0 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eFrequency Switching-Back-Delay (doF)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eAdjustable 0 (\u0026gt;200 ms)...6.000 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eVector-Shift Switching-Delay (dAL)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 50 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eVector-Shift Switching-Back-Delay (doF)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eAdjustable 3...240 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDelay At Us On\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eAdjustable 2...20 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003ePassive Anti-Islanding Protection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eAcc. to ch. 6.5.3 and app. D2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOperating Temperature\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-20 °C...+55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-25 °C...+70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDesign \/ Installation Frame\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eV6 \/ Front mounting kit type ER6, 6 TE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions (H x W x D)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e90 x 105 x 69 mm, mounting height 66 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eProtection Housing\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eIP30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eProtection Terminals\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eAttachment\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eDIN-rail 35 mm according to EN 60 715 or screws M4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eApprox. 250 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364324765979,"sku":"VIC-REL100100000","price":1209.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/VIC-REL100100000-01.jpg?v=1781658928"},{"product_id":"victron-autotransformer-120-240v-100a","title":"Victron Energy - 120V\/240V - 100A - Autotransformer","description":"\u003ch2\u003eVictron 100A Autotransformer: Precision Voltage Conversion and Split-Phase Balancing for Critical Power Systems\u003c\/h2\u003e\n\u003ch3\u003eEngineered for Reliable Step-Up, Step-Down, and Load Balancing in 120\/240V Applications\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eVictron 100A Autotransformer\u003c\/strong\u003e is a robust, toroidal transformer designed to solve the challenges of split-phase power distribution. In systems where 120V and 240V loads coexist, unbalanced currents can severely limit usable capacity. This unit actively balances the load across both legs, enabling you to draw the full rated power from your supply—whether it’s a generator, grid connection, or inverter setup.\u003c\/p\u003e\n\u003cp\u003eBy creating a new neutral point, the autotransformer absorbs current differences between the two 120V legs. This means a 30A 120\/240V supply can deliver its full 7.2kVA potential, rather than being restricted to as little as 4.8kVA due to imbalance. For installers and system designers, this translates to fewer overload trips, better utilisation of existing infrastructure, and a more stable power environment for sensitive equipment.\u003c\/p\u003e\n\u003ch3\u003eHow It Solves Real-World Power Problems\u003c\/h3\u003e\n\u003cp\u003eIn typical mobile, marine, or off-grid installations, 120V appliances like hairdryers, washing machines, or air conditioners can draw heavily from one leg while the other remains lightly loaded. Without balancing, the supply breaker may trip prematurely, even though total power draw is well below the theoretical maximum. The Victron Autotransformer eliminates this bottleneck, allowing dynamic redistribution of current so that both legs operate efficiently.\u003c\/p\u003e\n\u003cp\u003eThis capability is particularly valuable when using a single 240V inverter instead of stacking two 120V units. A stacked pair of 120V 3kVA inverters limits each leg to 25A regardless of load distribution. In contrast, a 240V 5kVA inverter paired with this autotransformer can supply up to 38.5A on one leg if the other draws only 3.5A—offering greater flexibility and often reducing equipment costs.\u003c\/p\u003e\n\u003ch3\u003eBuilt-In Safety and Protection Features\u003c\/h3\u003e\n\u003cp\u003eSafety is integral to the design. An integrated \u003cstrong\u003eground relay\u003c\/strong\u003e ensures the neutral is properly bonded when operating in inverter mode, which is essential for the correct function of Ground Fault Circuit Interrupters (GFCIs). The relay is controlled directly by a compatible Victron Multi or Quattro inverter\/charger, simplifying installation and compliance.\u003c\/p\u003e\n\u003cp\u003eThermal protection guards against overheating: if internal temperatures rise beyond safe limits, the unit disconnects automatically. Reset is manual, prompting a check of ventilation and load conditions before resuming operation. The \u003cstrong\u003e100A two-pole circuit breaker\u003c\/strong\u003e provides additional overcurrent protection on the input side.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eToroidal transformer design for high efficiency and low noise\u003c\/li\u003e\n\u003cli\u003eContinuous neutral current rating of 28A at 40°C, with 32A for 30 minutes\u003c\/li\u003e\n\u003cli\u003eIntegrated ground relay for seamless inverter neutral bonding\u003c\/li\u003e\n\u003cli\u003eManual-reset thermal protection prevents damage from overload\u003c\/li\u003e\n\u003cli\u003eRobust aluminium enclosure with IP21 protection rating\u003c\/li\u003e\n\u003cli\u003eScrew terminals accept up to 35mm² (AWG 2) cable for secure, low-resistance connections\u003c\/li\u003e\n\u003cli\u003eCompact footprint: 425 x 214 x 110mm, weight 13.5kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications Across Mobile, Marine, and Off-Grid\u003c\/h3\u003e\n\u003cp\u003eThis autotransformer is an essential component for any split-phase system where load balance cannot be guaranteed. Typical use cases include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRV and caravan power systems with a mix of 120V and 240V appliances\u003c\/li\u003e\n\u003cli\u003eMarine electrical panels requiring stable split-phase supply from a single inverter\u003c\/li\u003e\n\u003cli\u003eOff-grid cabins or tiny homes using generators or inverters as primary power sources\u003c\/li\u003e\n\u003cli\u003eBackup power setups where generator capacity must be fully utilised\u003c\/li\u003e\n\u003cli\u003eIndustrial or commercial mobile power carts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWhether you’re upgrading an existing Victron installation or designing a new system, the 100A Autotransformer provides the balancing capability needed to maximise available power and protect connected equipment.\u003c\/p\u003e\n\u003ch3\u003eInstallation-Ready Design\u003c\/h3\u003e\n\u003cp\u003eThe unit ships with clear wiring diagrams and features accessible screw terminals, dual cable glands for secure cable entry, and mounting feet for fixed installation. LED indicators on the front panel provide at-a-glance status for power, ground relay engagement, and temperature warnings, aiding commissioning and troubleshooting.\u003c\/p\u003e\n\u003cp\u003eFor systems requiring step-up conversion from 120V to 240V, the autotransformer can be configured accordingly, adding versatility to its split-phase balancing core function.\u003c\/p\u003e\n\u003ch3\u003eMaximise Your Power System’s Potential\u003c\/h3\u003e\n\u003cp\u003eEquip your installation with the Victron 100A Autotransformer to eliminate load imbalance limitations and ensure reliable, full-capacity operation. \u003cstrong\u003eOrder today\u003c\/strong\u003e to build a more resilient and efficient power system.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eInput\/Output Voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e120 \/ 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eInput Circuit Breaker\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e100 A, Two Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eFrequency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum 240 V Feed Through Current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNeutral Current, 30 Min\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e32 A (3800 VA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNeutral Current, Continuous\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e28 A @ 40 °C \/ 100 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eTransformer Type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eToroidal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eElectrical Terminals\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eScrew Terminals 35 mm² \/ AWG 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEnclosure\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eAluminium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eProtection Category\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eIP21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eSafety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 60076\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e13.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions (H x W x D)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e425 x 214 x 110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364325093659,"sku":"VIC-ITR000100101","price":724.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/VIC-ITR000100101-01.jpg?v=1781658041"},{"product_id":"victron-filax-2-transfer-switch-ce-230v-50hz-240v","title":"Victron Energy - 230V\/50Hz Filax 2 Automatic Transfer Switch","description":"\u003ch2\u003eVictron Filax 2: Ultra-Fast Automatic Transfer Switch for 240V Systems\u003c\/h2\u003e\n\u003ch3\u003eSeamless Power Continuity for Critical Electronics\u003c\/h3\u003e\n\u003cp\u003eThe Victron Filax 2 is an advanced automatic transfer switch engineered to provide rapid, reliable changeover between two alternating current (AC) sources. Designed specifically for sensitive electronics, it ensures that computers, industrial control systems, and modern entertainment equipment continue operating without disruption during a power source transition. By monitoring the priority source, which is typically mains power, a generator, or shore power, the unit will seamlessly shift the load to an alternate source, such as a battery inverter, the moment the primary supply fails or fluctuates.\u003c\/p\u003e\n\u003ch3\u003ePrecision Open Transition Changeover\u003c\/h3\u003e\n\u003cp\u003eOperating as an open transition, or \"break before make\" transfer switch, this unit executes a load transfer in less than 16 milliseconds. This ultra-fast switching time is critical for preventing resets or data loss in sensitive microprocessor-based equipment. The load is normally powered by the priority source. If the priority voltage drops below a specific threshold, or if the frequency deviates outside acceptable high or low limits, the changeover switch immediately activates the alternate source.\u003c\/p\u003e\n\u003cp\u003eTo prevent rapid toggling between power supplies during intermittent faults, the system incorporates a smart reverse transfer mechanism. The load will only revert to the priority source once it has operated within safe voltage and frequency limits for a continuous 30 seconds.\u003c\/p\u003e\n\u003ch3\u003eEngineered for Caravans, Marine, and Industrial Use\u003c\/h3\u003e\n\u003cp\u003eWhether you are configuring a 240V changeover switch for a caravan solar system, managing marine shore power connections, or securing remote industrial controls, this unit delivers exceptional reliability. Its robust ABS enclosure features IP65-rated cable glands to protect internal connections from dust and moisture, making it highly resilient in demanding mobile environments. Clear front-panel LED indicators provide immediate visual feedback regarding the active power source and any detected faults.\u003c\/p\u003e\n\u003cp\u003ePlease note that this transfer switch is specifically optimised for critical and sensitive loads. It is not intended to supply high-power household appliances with massive startup surges, such as washing machines or heavy-duty electric motors. Both inputs must be protected by appropriate circuit breakers rated no higher than 16 amps.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUltra-fast transfer time:\u003c\/strong\u003e Less than 16ms changeover ensures continuous operation of sensitive digital loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmart reverse transfer:\u003c\/strong\u003e A 30-second delay verifies priority source stability before switching back.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelectable frequency:\u003c\/strong\u003e Easily configurable for 50Hz or 60Hz systems via an internal jumper plug.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobust environmental protection:\u003c\/strong\u003e Features an IP65-rated cable entry system and durable ABS casing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh capacity:\u003c\/strong\u003e Supports up to 16 Amps of current across both priority and alternate inputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus monitoring:\u003c\/strong\u003e Integrated LEDs for priority source, alternate source, and fault diagnostics.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSecure and Straightforward Integration\u003c\/h3\u003e\n\u003cp\u003eDesigned for surface mounting, the compact enclosure includes pre-drilled side flanges for a secure fit in tight utility spaces. Dedicated terminal blocks for Phase, Neutral, and Earth connections on all inputs ensure an organised and safe electrical installation. For loads operating below 850 Watts, internal wire bridges can be easily removed to optimise performance.\u003c\/p\u003e\n\u003cp\u003eUpgrade your off-grid, marine, or mobile power system with reliable automatic changeover capabilities. Integrate the Victron Filax 2 into your electrical network today to maintain flawless operation of your most critical AC equipment.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eFilax 2 Transfer Switch CE 230V\/50Hz-240V\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003ePart Number\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eSDFI0000000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOpen Transition Transfer\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eBreak Before Make\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum Current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003ePriority Source: Low Voltage Switching Threshold\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e180 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003ePriority Source: Low Voltage Reverse Switching Threshold\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e188 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003ePriority Source: Low Frequency Switching Threshold\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e45 Hz (230V\/50Hz); 46 Hz (240V\/60Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003ePriority Source: Low Frequency Reverse Switching Threshold\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e47 Hz (230V\/50Hz); 52 Hz (240V\/60Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003ePriority Source: High Frequency Switching Threshold\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e60 Hz (230V\/50Hz); 68 Hz (240V\/60Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003ePriority Source: High Frequency Reverse Switching Threshold\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e56 Hz (230V\/50Hz); 63 Hz (240V\/60Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003ePriority Source: Maximum Continuous Input Voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e260 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eAlternate Source: Maximum Continuous Input Voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e260 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum Load Transfer Time And Reverse Transfer Time\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e16 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eReverse Switching Delay (Seconds)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e30 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eLED Indicators\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eLoad Supplied By Priority Source: Yellow; Load Supplied By Alternate Source: Yellow; Priority Source Fault: Red\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOperating Temperature Range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-20°C up to +50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum (Non-Condensing) Humidity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eABS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eColour\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eRAL7035 (Light Grey)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eProtection Category\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions (H x W x D)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e120 x 255 x 75 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eSafety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 60335-1, EN 60335-2-29\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEmission And Immunity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 55014-1, EN 55014-2, EN 61000-3-3, EN 61000-6-3, EN 61000-6-2, EN 61000-6-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364361072923,"sku":"VIC-SDFI0000000","price":389.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/VIC-SDFI0000000-01.jpg?v=1781659083"},{"product_id":"victron-galvanic-isolator-vdi-16-a","title":"Victron Energy - 16A - VDI-16 Galvanic Isolator","description":"\u003ch2\u003eVictron Galvanic Isolator: Advanced Electrolytic Corrosion Protection for Marine Vessels\u003c\/h2\u003e\n\u003ch3\u003eEngineered to Block Stray DC Currents and Preserve Underwater Metals\u003c\/h3\u003e\n\u003cp\u003eThe Victron Galvanic Isolator is a critical component for any vessel connected to shore power, designed to prevent electrolytic corrosion of underwater metals such as the hull, propeller, shaft, and through-hull fittings. By installing this device in series with the protective earth conductor between the shore supply and the boat's grounding system, you effectively block low-voltage DC galvanic currents that would otherwise flow through the water, causing accelerated corrosion. Unlike generic isolators that may fail under fault conditions, the Victron unit uses robust internal diodes in an anti-parallel configuration, ensuring reliable isolation during normal operation while automatically conducting during AC fault currents to maintain safety.\u003c\/p\u003e\n\u003ch3\u003eHow It Works: Reliable Diode-Based Isolation\u003c\/h3\u003e\n\u003cp\u003eAt the core of the Victron Galvanic Isolator are high-capacity diodes that block DC voltages up to approximately 1.4 V. This threshold is higher than the naturally occurring potential differences between dissimilar underwater metals, effectively stopping corrosive currents. In the event of an AC fault, the diodes conduct, allowing the fault current to flow and trip the upstream residual-current device (RCD) or circuit breaker, ensuring personal safety and compliance with marine electrical standards. The fully potted, waterproof construction (IP67) protects internal electronics from moisture, salt spray, and condensation, making it suitable for installation in engine rooms, lazarettes, and other harsh marine environments.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlocks galvanic corrosion currents\u003c\/strong\u003e – Prevents DC leakage via the shore earth connection, protecting underwater metals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh peak current withstand\u003c\/strong\u003e – Handles transient fault currents up to 1600 A (20 ms), ensuring durability during short circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous current rating\u003c\/strong\u003e – Supports up to 16 A, matching typical shore power demands\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP67 waterproof and fully potted\u003c\/strong\u003e – Resistant to moisture ingress, ideal for marine and coastal installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnodised aluminium heat sink\u003c\/strong\u003e – Passive cooling design dissipates heat efficiently, no fans required\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSimple two-stud connection\u003c\/strong\u003e – M6 (approx. 1\/4\") stud terminals for secure, low-resistance wiring\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact and robust\u003c\/strong\u003e – Dimensions 60 x 120 x 200 mm, weight 1 kg, with integrated mounting slots\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliant with marine standards\u003c\/strong\u003e – Meets relevant safety and EMC requirements for onboard use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Choose a Victron Galvanic Isolator?\u003c\/h3\u003e\n\u003cp\u003eMany boat owners underestimate the risk of galvanic corrosion until costly damage appears. A shore power connection, while convenient, creates a conductive path between your vessel and neighbouring boats or the marina's metal structures. Without isolation, even small DC voltages can drive destructive currents through the water. The Victron Galvanic Isolator breaks this path for DC while preserving the safety earth for AC faults. Its robust design, with a peak current rating far exceeding typical fault levels, ensures it will not fail when needed most. The anodised aluminium enclosure provides excellent heat dissipation, maintaining performance even under sustained high currents. Installation is straightforward: mount the isolator close to the shore power inlet, connect the shore earth to one stud and the boat's earth to the other, and secure the wiring with appropriate lugs. No ongoing maintenance is required.\u003c\/p\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThis galvanic isolator is suitable for a wide range of vessels, from small pleasure craft to larger yachts and commercial boats, wherever a shore power connection is used. It is particularly valuable in marinas with high electrical activity, where stray currents are common. Whether you are fitting out a new build or retrofitting an existing electrical system, the Victron Galvanic Isolator provides peace of mind by protecting your investment against hidden corrosion.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: For optimal protection, ensure your vessel's anodes are in good condition and regularly inspected. The galvanic isolator works in conjunction with, not as a replacement for, sacrificial anodes.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSecure Your Vessel's Underwater Metals Today\u003c\/h3\u003e\n\u003cp\u003eDon't let electrolytic corrosion compromise your boat's integrity. Install a Victron Galvanic Isolator and sail with confidence, knowing your underwater metals are protected.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum Current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003ePeak Current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e1600 A \/ 20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eConnection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e2 Studs M6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eAnodized Aluminium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eProtection Category\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eIP 67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions (HxWxD)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e60 x 120 x 200 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364362711323,"sku":"VIC-GDI000016000","price":149.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/VIC-GDI000016000-01.jpg?v=1781658044"},{"product_id":"victron-galvanic-isolator-vdi-32-a","title":"Victron Energy - 32A - VDI-32 - Galvanic Isolator","description":"\u003ch2\u003eVictron Galvanic Isolator: Advanced Electrolytic Corrosion Protection for Marine Vessels\u003c\/h2\u003e\n\u003ch3\u003eEngineered to Block Stray DC Currents and Preserve Underwater Metals\u003c\/h3\u003e\n\u003cp\u003eThe Victron Galvanic Isolator is a critical component for any vessel connected to shore power, designed to prevent electrolytic corrosion of underwater metals such as the hull, propeller, shaft, and through-hull fittings. By installing this device in series with the protective earth conductor between the shore supply and the boat's grounding system, you effectively block low-voltage DC galvanic currents that would otherwise flow through the water, causing accelerated corrosion. Unlike generic isolators that may fail under fault conditions, the Victron unit uses robust internal diodes in an anti-parallel configuration, ensuring reliable isolation during normal operation while automatically conducting during AC fault currents to maintain safety.\u003c\/p\u003e\n\u003ch3\u003eHow It Works: Reliable Diode-Based Isolation\u003c\/h3\u003e\n\u003cp\u003eAt the core of the Victron Galvanic Isolator are high-capacity diodes that block DC voltages up to approximately 1.4 V. This threshold is higher than the naturally occurring potential differences between dissimilar underwater metals, effectively stopping corrosive currents. In the event of an AC fault, the diodes conduct, allowing the fault current to flow and trip the upstream residual-current device (RCD) or circuit breaker, ensuring personal safety and compliance with marine electrical standards. The fully potted, waterproof construction (IP67) protects internal electronics from moisture, salt spray, and condensation, making it suitable for installation in engine rooms, lazarettes, and other harsh marine environments.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlocks galvanic corrosion currents\u003c\/strong\u003e – Prevents DC leakage via the shore earth connection, protecting underwater metals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh peak current withstand\u003c\/strong\u003e – Handles transient fault currents up to 3200 A (20 ms), ensuring durability during short circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous current rating\u003c\/strong\u003e – Supports up to 32 A, matching typical shore power demands\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP67 waterproof and fully potted\u003c\/strong\u003e – Resistant to moisture ingress, ideal for marine and coastal installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnodised aluminium heat sink\u003c\/strong\u003e – Passive cooling design dissipates heat efficiently, no fans required\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSimple two-stud connection\u003c\/strong\u003e – M6 (approx. 1\/4\") stud terminals for secure, low-resistance wiring\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact and robust\u003c\/strong\u003e – Dimensions 63 x 164 x 200 mm, weight 2 kg, with integrated mounting slots\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliant with marine standards\u003c\/strong\u003e – Meets relevant safety and EMC requirements for onboard use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Choose a Victron Galvanic Isolator?\u003c\/h3\u003e\n\u003cp\u003eMany boat owners underestimate the risk of galvanic corrosion until costly damage appears. A shore power connection, while convenient, creates a conductive path between your vessel and neighbouring boats or the marina's metal structures. Without isolation, even small DC voltages can drive destructive currents through the water. The Victron Galvanic Isolator breaks this path for DC while preserving the safety earth for AC faults. Its robust design, with a peak current rating far exceeding typical fault levels, ensures it will not fail when needed most. The anodised aluminium enclosure provides excellent heat dissipation, maintaining performance even under sustained high currents. Installation is straightforward: mount the isolator close to the shore power inlet, connect the shore earth to one stud and the boat's earth to the other, and secure the wiring with appropriate lugs. No ongoing maintenance is required.\u003c\/p\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThis galvanic isolator is suitable for a wide range of vessels, from small pleasure craft to larger yachts and commercial boats, wherever a shore power connection is used. It is particularly valuable in marinas with high electrical activity, where stray currents are common. Whether you are fitting out a new build or retrofitting an existing electrical system, the Victron Galvanic Isolator provides peace of mind by protecting your investment against hidden corrosion.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: For optimal protection, ensure your vessel's anodes are in good condition and regularly inspected. The galvanic isolator works in conjunction with, not as a replacement for, sacrificial anodes.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSecure Your Vessel's Underwater Metals Today\u003c\/h3\u003e\n\u003cp\u003eDon't let electrolytic corrosion compromise your boat's integrity. Install a Victron Galvanic Isolator and sail with confidence, knowing your underwater metals are protected.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum Current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003ePeak Current (20 ms)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e3200 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eConnection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eM6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eAnodized Aluminium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eProtection Category\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eIP 67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions (H x W x D)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e63 x 164 x 200 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364362842395,"sku":"VIC-GDI000032000","price":339.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/VIC-GDI000032000-01.jpg?v=1781658044"},{"product_id":"victron-galvanic-isolator-vdi-64-a","title":"Victron Energy - 64A - VDI-64 - Galvanic Isolator","description":"\u003ch2\u003eVictron Galvanic Isolator: Advanced Electrolytic Corrosion Protection for Marine Vessels\u003c\/h2\u003e\n\u003ch3\u003eEngineered to Block Stray DC Currents and Preserve Underwater Metals\u003c\/h3\u003e\n\u003cp\u003eThe Victron Galvanic Isolator is a critical component for any vessel connected to shore power, designed to prevent electrolytic corrosion of underwater metals such as the hull, propeller, shaft, and through-hull fittings. By installing this device in series with the protective earth conductor between the shore supply and the boat's grounding system, you effectively block low-voltage DC galvanic currents that would otherwise flow through the water, causing accelerated corrosion. Unlike generic isolators that may fail under fault conditions, the Victron unit uses robust internal diodes in an anti-parallel configuration, ensuring reliable isolation during normal operation while automatically conducting during AC fault currents to maintain safety.\u003c\/p\u003e\n\u003ch3\u003eHow It Works: Reliable Diode-Based Isolation\u003c\/h3\u003e\n\u003cp\u003eAt the core of the Victron Galvanic Isolator are high-capacity diodes that block DC voltages up to approximately 1.4 V. This threshold is higher than the naturally occurring potential differences between dissimilar underwater metals, effectively stopping corrosive currents. In the event of an AC fault, the diodes conduct, allowing the fault current to flow and trip the upstream residual-current device (RCD) or circuit breaker, ensuring personal safety and compliance with marine electrical standards. The fully potted, waterproof construction (IP67) protects internal electronics from moisture, salt spray, and condensation, making it suitable for installation in engine rooms, lazarettes, and other harsh marine environments.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlocks galvanic corrosion currents\u003c\/strong\u003e – Prevents DC leakage via the shore earth connection, protecting underwater metals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh peak current withstand\u003c\/strong\u003e – Handles transient fault currents up to 6000 A (20 ms), ensuring durability during short circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous current rating\u003c\/strong\u003e – Supports up to 64 A, matching typical shore power demands\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP67 waterproof and fully potted\u003c\/strong\u003e – Resistant to moisture ingress, ideal for marine and coastal installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnodised aluminium heat sink\u003c\/strong\u003e – Passive cooling design dissipates heat efficiently, no fans required\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSimple two-stud connection\u003c\/strong\u003e – M6 (approx. 1\/4\") stud terminals for secure, low-resistance wiring\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact and robust\u003c\/strong\u003e – Dimensions 63 x 164 x 335 mm, weight 3.2 kg, with integrated mounting slots\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliant with marine standards\u003c\/strong\u003e – Meets relevant safety and EMC requirements for onboard use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Choose a Victron Galvanic Isolator?\u003c\/h3\u003e\n\u003cp\u003eMany boat owners underestimate the risk of galvanic corrosion until costly damage appears. A shore power connection, while convenient, creates a conductive path between your vessel and neighbouring boats or the marina's metal structures. Without isolation, even small DC voltages can drive destructive currents through the water. The Victron Galvanic Isolator breaks this path for DC while preserving the safety earth for AC faults. Its robust design, with a peak current rating far exceeding typical fault levels, ensures it will not fail when needed most. The anodised aluminium enclosure provides excellent heat dissipation, maintaining performance even under sustained high currents. Installation is straightforward: mount the isolator close to the shore power inlet, connect the shore earth to one stud and the boat's earth to the other, and secure the wiring with appropriate lugs. No ongoing maintenance is required.\u003c\/p\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThis galvanic isolator is suitable for a wide range of vessels, from small pleasure craft to larger yachts and commercial boats, wherever a shore power connection is used. It is particularly valuable in marinas with high electrical activity, where stray currents are common. Whether you are fitting out a new build or retrofitting an existing electrical system, the Victron Galvanic Isolator provides peace of mind by protecting your investment against hidden corrosion.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: For optimal protection, ensure your vessel's anodes are in good condition and regularly inspected. The galvanic isolator works in conjunction with, not as a replacement for, sacrificial anodes.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSecure Your Vessel's Underwater Metals Today\u003c\/h3\u003e\n\u003cp\u003eDon't let electrolytic corrosion compromise your boat's integrity. Install a Victron Galvanic Isolator and sail with confidence, knowing your underwater metals are protected.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eGalvanic Isolator\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eWaterproof (Potted)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum Current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e64 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003ePeak Current (20 ms)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e6000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eConnection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eM6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eHeat Sink Material\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eAnodized Aluminium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eProtection Category\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eIP 67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e3.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions (H x W x D)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e63 x 164 x 335 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eVoltage At Which Diodes Conduct\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eAbout 1.4 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364363104539,"sku":"VIC-GDI000064000","price":409.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/VIC-GDI000064000-01.jpg?v=1781658044"},{"product_id":"victron-isolation-transformer-2000w-115-230v","title":"Victron Energy - 115\/230V 2000W - Isolation Transformer","description":"\u003ch2\u003eVictron 2000W Isolation Transformer: Complete Marine Electrical Safety\u003c\/h2\u003e\n\u003cp\u003eConnecting your vessel to shore power introduces significant electrical challenges, primarily galvanic corrosion and grounding safety risks. The \u003cstrong\u003eVictron 2000W 115\/230V Isolation Transformer\u003c\/strong\u003e eliminates electrical continuity between AC shore power and your boat. By completely isolating your vessel from the shore ground, this system provides absolute protection against galvanic corrosion while ensuring that your onboard safety devices function correctly.\u003c\/p\u003e\n\u003ch3\u003ePrevent Galvanic Corrosion and Protect Your Hull\u003c\/h3\u003e\n\u003cp\u003eGalvanic corrosion occurs when two dissimilar metals are in electrical contact and exposed to a conductive fluid, such as seawater or freshwater. When a boat is connected to shore power, the shore earth wire connects the underwater metals of your boat to other boats and shore structures. This shared connection rapidly accelerates galvanic corrosion, dissolving sacrificial anodes prematurely and attacking vital metal components like your hull, propeller, and shaft.\u003c\/p\u003e\n\u003cp\u003eWhile some marine setups rely on simple galvanic isolators, these do not provide true electrical separation. The Victron Isolation Transformer physically separates the shore power from your onboard system. The shore supply feeds the primary side of the transformer, and your vessel is powered entirely by the secondary side. This breaks the earth circuit completely, stopping galvanic corrosion at the source without compromising electrical safety.\u003c\/p\u003e\n\u003ch3\u003eEnsure Critical Grounding Safety\u003c\/h3\u003e\n\u003cp\u003eA common but highly dangerous workaround to stop galvanic corrosion is disconnecting the shore ground wire. If a short circuit occurs without a proper ground connection, safety devices like a Ground Fault Current Interrupter (GFCI) or Residual Current Device (RCD) will fail to trip, leading to severe electrical hazards.\u003c\/p\u003e\n\u003cp\u003eThis isolation transformer solves the problem by creating a safe, isolated neutral-to-earth bond on the secondary side of the transformer. By connecting all metal parts of your boat to this secondary neutral output, any short circuit will immediately trigger your GFCI or blow a fuse, keeping the vessel and its occupants completely safe. It also eliminates the need for complex polarity alarms.\u003c\/p\u003e\n\u003ch3\u003eBuilt-In Soft Start Technology\u003c\/h3\u003e\n\u003cp\u003eHigh-capacity transformers typically draw a massive inrush current when first connected, which can easily trip sensitive shore power circuit breakers. To counter this, Victron Energy has integrated an intelligent soft start feature into this model. The soft start system manages the initial power draw, ensuring a smooth connection to the shore supply without nuisance breaker trips, regardless of the marina's power quality.\u003c\/p\u003e\n\u003ch3\u003eDurable Hardware for Marine Environments\u003c\/h3\u003e\n\u003cp\u003eDesigned specifically for demanding marine and off-grid environments, the unit is housed in a robust enclosure featuring the distinctive Victron Blue Power branding. It includes built-in recessed handles on the sides for secure manual lifting and positioning during installation. Protective black cable glands provide secure, strain-relieved electrical connections, preventing moisture ingress and ensuring long-term reliability in harsh coastal conditions.\u003c\/p\u003e\n\u003ch3\u003eKey Features and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal Electrical Isolation:\u003c\/strong\u003e Completely separates shore power from the vessel supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCorrosion Prevention:\u003c\/strong\u003e Eliminates the earth loop that causes severe galvanic corrosion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnhanced Safety:\u003c\/strong\u003e Ensures proper operation of onboard RCDs, GFCIs, and fuses.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoft Start Protection:\u003c\/strong\u003e Prevents shore power breakers from tripping due to high inrush currents.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Voltage Handling:\u003c\/strong\u003e Engineered to support both 115V and 230V configurations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine-Grade Construction:\u003c\/strong\u003e Durable enclosure with recessed lifting handles and secure cable glands.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProtect Your Investment Today\u003c\/h3\u003e\n\u003cp\u003eUpgrading to a true isolation transformer is the most effective method to safeguard your hull from corrosion and protect your electrical system from grounding faults. Equip your marine electrical system with the Victron 2000W 115\/230V Isolation Transformer to ensure reliable, safe shore power connectivity wherever you dock.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003ePower Rating\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e2000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eAC Input Voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e115 or 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eAC Output Voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e120 or 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eFrequency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput Current Rating\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e17 A (115 V); 8.5 A (230 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eSoft Start\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOperating Temperature Range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-20 °C to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eHumidity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eMax 95%, Non-Condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eTransformer Type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eToroidal (Low Noise, Low Weight), 1:1.05 Ratio\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEnclosure\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eAluminium (Blue RAL 5012)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eProtection Category\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eIP21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eSafety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 60076\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e12.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions (H x W x D)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e375 x 214 x 135 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMinimal Cable Cross-Sections\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e115 V: 2.5 mm² (AWG 13); 230 V: 1.5 mm² (AWG 16)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eModel Code\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eITR040202041\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364368773403,"sku":"VIC-ITR040202041","price":599.95,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/VIC-ITR040202041-01.jpg?v=1781658052"},{"product_id":"victron-plug-16a-250vac-2p-3w","title":"Victron Energy - 16A\/250Vac Shore Power Plug – Suits Stainless Steel Power Inlet","description":"\u003ch2\u003eVictron 16A\/250Vac Shore Power Plug – For Victron 16A Stainless Steel Power Inlet (CEE Standard, IP56 Rated)\u003c\/h2\u003e\n\u003ch3\u003eHigh-Quality 16A Shore Power Plug for Marine, RV, and Off-Grid Installations\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eVictron 16A\/250Vac Shore Power Plug\u003c\/strong\u003e is a durable, precision-engineered \u003cstrong\u003eCEE-standard plug\u003c\/strong\u003e designed specifically to fit the \u003cstrong\u003eVictron 16A Stainless Steel Shore Power Inlet\u003c\/strong\u003e. Built to deliver a safe, watertight, and efficient electrical connection, this plug is ideal for \u003cstrong\u003emarine, RV, caravan, off-grid, and industrial applications\u003c\/strong\u003e where performance and reliability are essential.\u003c\/p\u003e\n\u003ch3\u003ePerfect Match for Victron 16A Stainless Steel Power Inlet\u003c\/h3\u003e\n\u003cp\u003eDeveloped for seamless compatibility, this plug connects securely to the \u003cstrong\u003eVictron Stainless Steel 16A Inlet\u003c\/strong\u003e, ensuring a precise and weatherproof fit that prevents arcing and maintains excellent conductivity. It meets \u003cstrong\u003eCEE\/IEC 60309 (2P+E) 16A\/250V AC\u003c\/strong\u003e standards, offering a grounded, single-phase power connection trusted across marine, RV, and mobile environments globally.\u003c\/p\u003e\n\u003ch3\u003eDurable and Weather-Resistant Construction\u003c\/h3\u003e\n\u003cp\u003eManufactured from \u003cstrong\u003eimpact-resistant, UV-stabilised materials\u003c\/strong\u003e, the Victron 16A Shore Power Plug is designed to withstand tough outdoor and marine conditions. Its upgraded \u003cstrong\u003eIP56-rated housing\u003c\/strong\u003e provides superior waterproof and dust protection, ensuring dependable performance even in heavy spray, rain, or saltwater environments. High-quality brass terminals ensure a low-resistance, corrosion-free connection for safe and efficient power transfer over time.\u003c\/p\u003e\n\u003ch3\u003eIdeal for Marine, RV, and Mobile Power Systems\u003c\/h3\u003e\n\u003cp\u003eThis plug is an essential component of the \u003cstrong\u003eVictron Shore Power ecosystem\u003c\/strong\u003e, delivering professional-grade connectivity when used with the \u003cstrong\u003eVictron 16A Stainless Steel Power Inlet\u003c\/strong\u003e and \u003cstrong\u003eVictron Shore Power Cables\u003c\/strong\u003e. Designed for easy installation and repeat use, it provides reliable and watertight power access for vessels, caravans, and off-grid setups exposed to the elements.\u003c\/p\u003e\n\u003ch3\u003eKey Features and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCEE-standard (IEC 60309) 16A\/250V AC plug\u003c\/strong\u003e – 2P+E single-phase configuration with full grounding protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecifically designed to fit Victron 16A Stainless Steel Power Inlet\u003c\/strong\u003e for a precise and waterproof connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP56-rated weatherproof housing\u003c\/strong\u003e for superior resistance to water, dust, and environmental exposure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImpact-resistant and UV-stabilised body\u003c\/strong\u003e ensures long-lasting outdoor performance.\u003c\/li\u003e\n\u003cli\u003eIdeal for \u003cstrong\u003emarine, caravan, RV, off-grid, and industrial power systems\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eUpgrade to a Secure and Water Resistant Shore Power Connection\u003c\/h4\u003e\n\u003cp\u003eEnsure maximum safety and reliability with the \u003cstrong\u003eVictron 16A\/250Vac Shore Power Plug (IP56)\u003c\/strong\u003e, perfectly matched to the Victron Stainless Steel Power Inlet. Built to CEE standards and engineered for demanding environments, it provides the watertight durability and consistent performance your power system deserves. \u003cstrong\u003eUpgrade your vessel, caravan, or off-grid setup today\u003c\/strong\u003e and enjoy long-lasting, weatherproof Victron Energy connectivity.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eVictron Energy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003ePart Number\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eSHP301604000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003ePlug 16A\/250Vac (2p\/3w) for Power Inlet 16A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCurrent Rating\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eVoltage Rating\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e250 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eConfiguration\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e2p\/3w\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCompatible With\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003ePower Inlet 16A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eIP Rating\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eIP56\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 60309-1:1999 +A1:2007 +A2:2012+AC: 2014\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364410749211,"sku":"VIC-SHP301604000","price":114.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/VIC-SHP301604000-01.jpg?v=1781659090"},{"product_id":"victron-plug-32a-250vac-2p-3w","title":"Victron Energy - 32A\/250Vac Shore Power Plug – Suits Stainless Steel Power Inlet","description":"\u003ch2\u003eVictron 32A\/250Vac Shore Power Plug – For Stainless Steel 32A Victron Power Inlet (CEE Standard)\u003c\/h2\u003e\n\u003ch3\u003eHigh-Quality 32A Shore Power Plug for Marine, RV, and Off-Grid Installations\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eVictron 32A\/250Vac Shore Power Plug\u003c\/strong\u003e is a premium-grade \u003cstrong\u003eCEE-standard plug\u003c\/strong\u003e designed specifically to pair with the \u003cstrong\u003eVictron Stainless Steel 32A Power Inlet\u003c\/strong\u003e. Built for superior conductivity and long-lasting performance, this plug ensures a secure and watertight connection for reliable energy transfer in \u003cstrong\u003emarine, RV, caravan, and industrial environments\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003ePerfect Match for Victron Stainless Steel 32A Inlet\u003c\/h3\u003e\n\u003cp\u003eThis plug has been precision-engineered to \u003cstrong\u003efit the Victron 32A stainless steel shore power inlet\u003c\/strong\u003e perfectly, providing a seamless connection that maintains electrical integrity even under high-load operation. Designed to meet the \u003cstrong\u003eCEE\/IEC 60309 (2P+E) 32A\/250V AC\u003c\/strong\u003e standard, it offers full compatibility with Victron’s professional-grade power solutions and other CEE-conforming systems.\u003c\/p\u003e\n\u003ch3\u003eDurable and Safe Construction\u003c\/h3\u003e\n\u003cp\u003eManufactured from \u003cstrong\u003eimpact-resistant, weatherproof materials\u003c\/strong\u003e, the Victron 32A plug withstands heavy use in demanding conditions. Its \u003cstrong\u003eIP56-rated housing\u003c\/strong\u003e provides water and dust protection, while the solid internal brass terminals ensure secure, low-resistance contact for safe and efficient energy transfer. This design guarantees long-term reliability and consistent performance across a wide range of outdoor applications.\u003c\/p\u003e\n\u003ch3\u003eIdeal for Marine, RV, and Off-Grid Power Systems\u003c\/h3\u003e\n\u003cp\u003eWhether you’re connecting shore power to a yacht, motorhome, or remote power installation, the Victron 32A Plug offers a professional-grade solution built for dependability. Its rugged design and precision fit with Victron’s shore inlet range make it the ideal choice for maintaining consistent, safe, and weather-resistant power access.\u003c\/p\u003e\n\u003ch3\u003eKey Features and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCEE-standard (IEC 60309) 32A\/250V AC plug\u003c\/strong\u003e – 2P+E single-phase configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesigned to fit Victron Stainless Steel 32A Power Inlet\u003c\/strong\u003e perfectly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImpact-resistant and weatherproof housing\u003c\/strong\u003e for marine and outdoor durability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecure, watertight connection\u003c\/strong\u003e ensures reliable and safe power delivery.\u003c\/li\u003e\n\u003cli\u003eSuitable for \u003cstrong\u003emarine, RV, caravan, industrial, and off-grid systems\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eUpgrade Your Shore Power Connection with Victron Quality\u003c\/h4\u003e\n\u003cp\u003eEnsure a safe and seamless fit with your Victron inlet using the \u003cstrong\u003eVictron 32A\/250Vac Shore Power Plug\u003c\/strong\u003e. Built for performance, safety, and long-term reliability, it’s the professional choice for robust electrical connections in all marine and mobile power setups. \u003cstrong\u003eUpgrade your vessel, RV, or off-grid installation today\u003c\/strong\u003e with the trusted quality of Victron Energy.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eVictron Energy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003ePart Number\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eSHP303204000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOfficial Description\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003ePlug 32A\/250Vac (2p\/3w) for Power Inlet 32A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCurrent Rating\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eVoltage Rating\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e250 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eConfiguration\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e2p\/3w\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCompatible Inlet\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003ePower Inlet 32A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eHarmonised Standard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 60309-1:1999 +A1:2007 +A2:2012 +AC: 2014\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCompliance\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEU Low Voltage Directive 2014\/35\/EU; RoHS (2011\/65\/EU and 2015\/863\/EU); EC REACH Regulation (EC 1907\/2006)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCE Mark Date\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eApril 2015\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364410880283,"sku":"VIC-SHP303204000","price":144.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/VIC-SHP303204000-01.jpg?v=1781659090"},{"product_id":"victron-power-inlet-polyamid-with-cover-16a-250vac","title":"Victron Energy - 16A\/250Vac CEE Polyamid Power Inlet with Cover","description":"\u003ch2\u003eVictron Power Inlet Polyamid with Cover 16A\/250Vac (2p\/3w) – CEE Standard Shore Power Inlet\u003c\/h2\u003e\n\u003ch3\u003eReliable CEE-Standard Power Inlet for Marine, RV, and Off-Grid Use\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eVictron Power Inlet Polyamid with Cover 16A\/250Vac (2p\/3w)\u003c\/strong\u003e is a high-quality, \u003cstrong\u003eCEE-compliant shore power connection\u003c\/strong\u003e designed for safe and efficient power transfer in demanding environments. Built from rugged, UV-resistant polyamide and rated IP56 for water and dust protection, it’s ideal for \u003cstrong\u003emarine, caravan, RV, and off-grid applications\u003c\/strong\u003e where durability and reliability are essential.\u003c\/p\u003e\n\u003ch3\u003eCompatible with Victron Shore Power Cable Series\u003c\/h3\u003e\n\u003cp\u003eThis inlet is specifically designed to \u003cstrong\u003esuit the Victron Shore Power Cable Series\u003c\/strong\u003e, ensuring a perfect fit and secure connection every time. The combination delivers a watertight, low-resistance connection that minimizes voltage drop and maximizes electrical safety. It’s the perfect choice for users who demand full compatibility within the \u003cstrong\u003eVictron Energy system ecosystem\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eRugged Design with Protection Cap\u003c\/h3\u003e\n\u003cp\u003eA durable \u003cstrong\u003eprotection cap\u003c\/strong\u003e safeguards the inlet from environmental exposure when not in use, helping to extend component life and maintain system integrity. Whether installed on a yacht, RV, or tiny home, the Victron Power Inlet offers a dependable connection point even in harsh outdoor environments.\u003c\/p\u003e\n\u003ch3\u003eKey Features and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCEE-standard (IEC 60309) 16A\/250V AC shore power inlet\u003c\/strong\u003e – fully compatible with Victron Shore Power Cable Series.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWaterproof IP56-rated polyamid housing\u003c\/strong\u003e for superior durability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtective cap\u003c\/strong\u003e prevents water and dust ingress when not connected.\u003c\/li\u003e\n\u003cli\u003eIdeal for \u003cstrong\u003emarine, RV, caravan, off-grid, and tiny home power systems\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP56-rated weatherproof housing\u003c\/strong\u003e for superior resistance to water, dust, and environmental exposure.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eUpgrade Your Shore Power Connection Today\u003c\/h4\u003e\n\u003cp\u003eEnsure a reliable and weatherproof power setup with the \u003cstrong\u003eVictron CEE Power Inlet Polyamid with Cover 16A\/250Vac\u003c\/strong\u003e. Designed for seamless compatibility with the Victron Shore Power Cable Series, it’s the professional choice for safe, efficient, and long-lasting energy connections. \u003cstrong\u003eUpgrade your vehicle or vessel today\u003c\/strong\u003e for dependable power wherever you go.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003ePart Number\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eSHP301603000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCurrent Rating\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eVoltage Rating\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e250 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eIEC 60309, 2p+E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCover\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eGlass Filled PA6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003ePlug Body\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003ePA6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003ePins\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eBrass, Nickel Plated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e0.23 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWaterproof\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eIP 56\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCE Certified\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eFlange Diameter\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eØ87 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003ePanel Cut-out\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eØ55 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMounting Hole Diameter\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eØ4.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMounting Hole Centres\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e50 x 50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOverall Length\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e91.7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364411011355,"sku":"VIC-SHP301603000","price":114.95,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/VIC-SHP301603000-01.jpg?v=1781659089"},{"product_id":"victron-power-inlet-stainless-steel-with-cover-32a","title":"Victron Energy - 32A\/250Vac Stainless Steel Power Inlet with Cover","description":"\u003ch2\u003eVictron 32A\/250Vac Stainless Steel Shore Power Inlet with Cover – Heavy-Duty CEE Marine and RV Power Connection\u003c\/h2\u003e\n\u003ch3\u003ePremium 32A Stainless Steel Shore Power Inlet for Marine, RV, and Off-Grid Systems\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eVictron 32A\/250Vac Stainless Steel Shore Power Inlet with Cover\u003c\/strong\u003e is a professional-grade, \u003cstrong\u003eCEE-standard power connection point\u003c\/strong\u003e built for demanding environments. Constructed from high-quality \u003cstrong\u003emarine-grade stainless steel\u003c\/strong\u003e, this inlet ensures exceptional corrosion resistance, electrical reliability, and long-term durability—making it ideal for \u003cstrong\u003eboats, caravans, RVs, off-grid installations, and industrial power systems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eDesigned to CEE (IEC 60309) 32A Standard\u003c\/h3\u003e\n\u003cp\u003eThis inlet complies with the \u003cstrong\u003eCEE\/IEC 60309 (2P+E, 32A\/250V AC)\u003c\/strong\u003e specification, ensuring safe, grounded, and globally compatible power connectivity. The \u003cstrong\u003e2P+E (2p\/3w)\u003c\/strong\u003e single-phase configuration supports stable power transfer at high current loads, ideal for energy-intensive applications or larger onboard systems requiring consistent, safe, and efficient shore power delivery.\u003c\/p\u003e\n\u003ch3\u003eBuilt to Withstand Harsh Marine Conditions\u003c\/h3\u003e\n\u003cp\u003eEngineered for the toughest outdoor environments, this \u003cstrong\u003eIP56-rated stainless steel power inlet\u003c\/strong\u003e resists saltwater corrosion, UV exposure, and mechanical wear. The integrated \u003cstrong\u003eprotective cover\u003c\/strong\u003e seals the inlet when not in use, preventing ingress of water, dust, and debris. This ensures long-lasting reliability and optimal performance even in exposed marine or coastal locations.\u003c\/p\u003e\n\u003ch3\u003ePerfect Match for Victron Shore Power Cables\u003c\/h3\u003e\n\u003cp\u003eThe Victron 32A Stainless Steel Power Inlet is \u003cstrong\u003efully compatible with the Victron 32A Shore Power Cords and Plugs\u003c\/strong\u003e, offering a secure, watertight connection for maximum safety and efficiency. Together, these components form a complete, professional-grade power interface system trusted by marine engineers and off-grid professionals around the world.\u003c\/p\u003e\n\u003ch3\u003eKey Features and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCEE-standard (IEC 60309) 32A\/250V AC inlet\u003c\/strong\u003e – 2P+E single-phase configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine-grade stainless steel housing\u003c\/strong\u003e for maximum corrosion resistance and durability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP56-rated design\u003c\/strong\u003e with protective cover for superior weather protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible with Victron 32A Shore Power Plugs and Cables\u003c\/strong\u003e for a perfect system fit.\u003c\/li\u003e\n\u003cli\u003eIdeal for \u003cstrong\u003emarine, caravan, RV, off-grid, industrial, and tiny home installations\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eUpgrade Your Shore Power System with Professional-Grade Reliability\u003c\/h4\u003e\n\u003cp\u003eTrust the \u003cstrong\u003eVictron 32A\/250Vac Stainless Steel Shore Power Inlet with Cover\u003c\/strong\u003e for secure, corrosion-resistant, and high-capacity energy transfer. Built to withstand marine conditions and designed to integrate seamlessly with Victron’s shore power accessories, it’s the ultimate solution for safe and reliable power connections. \u003cstrong\u003eUpgrade your boat, caravan, or off-grid setup today\u003c\/strong\u003e and experience the uncompromising quality of Victron Energy.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003ePart Number\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eSHP303202000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCurrent Rating\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eVoltage Rating\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e250 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eIEC 60309, 2p+E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCover\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eSolid Cast 316 Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003ePlug Body\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003ePA6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003ePins\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eBrass, Nickel Plated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e0.65 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWaterproof\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eIP56\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCE Certified\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eRoHS Compliant\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOverall Diameter\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eØ105 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMounting Cut-out\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eØ74 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMounting Hole Diameter\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eØ5.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMounting Hole Centres\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e64 x 64 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOverall Length\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e118.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364411142427,"sku":"VIC-SHP303202000","price":194.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/VIC-SHP303202000-01.jpg?v=1781659091"},{"product_id":"victron-shore-power-cord-15m-16a-250vac-3x2-5sqmm","title":"Victron Energy - 16A\/250Vac Shore Power Cord - 15m","description":"\u003ch2\u003eVictron 15m 16A\/250Vac Shore Power Cord: Reliable Energy Transfer for Marine and RV Systems\u003c\/h2\u003e\n\u003ch3\u003eHigh-Visibility Shore Power for Demanding Environments\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eVictron 15m 16A\/250Vac Shore Power Cord\u003c\/strong\u003e is engineered to provide a secure and stable electrical connection between shore-based power pedestals and your vessel, caravan, or off-grid vehicle. Designed specifically for outdoor and marine use, this heavy-duty cable ensures your onboard systems receive consistent energy without compromising on safety. Featuring a bright, high-visibility yellow jacket, it significantly reduces tripping hazards around docks, campsites, and industrial areas.\u003c\/p\u003e\n\u003cp\u003eConstructed with premium marine-grade materials, this cable delivers a \u003cstrong\u003e16A\u003c\/strong\u003e maximum current capacity to support demanding electrical loads such as battery chargers, air conditioning units, and heavy-duty appliances. *Note typical de-rating factors apply to maximum current capacities under continuous load or elevated temperatures.\u003c\/p\u003e\n\u003ch3\u003eEngineered to Professional CEE Standards\u003c\/h3\u003e\n\u003cp\u003eSafety is paramount when transferring mains electricity in wet or outdoor environments. This shore power cord is built to international CEE (IEC 60309) specifications, featuring a standard 3-pin configuration that ensures a properly grounded, single-phase connection. The moulded male plug and female connector provide exceptional resistance to moisture and dust, keeping your electrical contacts clean and secure over years of frequent use.\u003c\/p\u003e\n\u003cp\u003eFor additional protection against the elements, the female connector includes an integrated weather-resistant dust cap. This keeps the terminals effectively shielded from saltwater spray, dirt, and debris when the cable is unplugged and stored away. Features an ergonomic yellow handle on the female connector for improved grip and ease of handling in wet conditions.\u003c\/p\u003e\n\u003ch3\u003eBuilt Tough for Australian Conditions\u003c\/h3\u003e\n\u003cp\u003eAustralian marine and outback environments subject equipment to extreme ultraviolet radiation, high humidity, and physical abrasion. The outer jacket of this \u003cstrong\u003e15m\u003c\/strong\u003e power cord is highly UV-stabilised and water-resistant, mitigating the cracking and degradation commonly seen in generic outdoor extension leads. Its excellent flexibility makes it easy to coil and store, even in colder weather, without kinking or retaining permanent bends.\u003c\/p\u003e\n\u003ch3\u003eSeamless System Integration\u003c\/h3\u003e\n\u003cp\u003eWhile compatible with standard CEE power pedestals, this cable is perfectly matched to high-quality shore power inlets, including Victron Energy stainless steel and polyamide models. Pairing this cable with a premium inlet creates a watertight, low-resistance circuit that protects your onboard electronics from voltage drops and electrical faults. This is an essential upgrade for any serious marine or mobile energy system.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-visibility yellow outer jacket reduces tripping risks and improves site safety.\u003c\/li\u003e\n\u003cli\u003eRobust CEE-standard 3-pin male plug and female connector for secure, grounded connections.\u003c\/li\u003e\n\u003cli\u003eRated for \u003cstrong\u003e16A\u003c\/strong\u003e maximum current to handle high-demand onboard appliances.\u003c\/li\u003e\n\u003cli\u003eMarine-grade, UV-stabilised, and water-resistant outer jacket built for longevity.\u003c\/li\u003e\n\u003cli\u003eFlexible construction ensures easy deployment and neat coiling for storage.\u003c\/li\u003e\n\u003cli\u003eIntegrated protective cap shields female terminals from moisture and dirt when not in use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eUpgrade Your Power Connection Today\u003c\/h3\u003e\n\u003cp\u003eRelying on standard household extension cords for marine or RV applications can lead to voltage drops, overheating, and serious safety hazards. Equip your vessel or vehicle with the \u003cstrong\u003eVictron 15m 16A\/250Vac Shore Power Cord\u003c\/strong\u003e to ensure safe, compliant, and highly efficient energy transfer wherever you plug in. Invest in professional-grade cabling to protect your onboard systems and enjoy complete peace of mind on your next journey.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCurrent Rating (A)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e16A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eVoltage Rating (VAC)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003ePlug Type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eMoulded IEC 60309 2p+E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003ePlug Colour\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eBlue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eConnector Type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eMoulded IEC 60309 3-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eConnector Colour\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eBlack \/ Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eLED light and protection cap on female connector\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCable Type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eH07BQ-F 3x 2.50mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCable Colour\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eYellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCable Length (m)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCable Size (mm²)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e2.50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight (kg)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e2.66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCE Certified\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364416778523,"sku":"VIC-SHP302501500","price":244.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/VIC-SHP302501500-01.jpg?v=1781659091"},{"product_id":"victron-shore-power-cord-15m-25a-250vac-3x4sqmm","title":"Victron Energy - 25A\/250Vac - Shore Power Cord - 15m","description":"\u003ch2\u003eVictron 15m 25A\/250Vac Shore Power Cord: Reliable Energy Transfer for Marine and RV Systems\u003c\/h2\u003e\n\u003ch3\u003eHigh-Visibility Shore Power for Demanding Environments\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eVictron 15m 25A\/250Vac Shore Power Cord\u003c\/strong\u003e is engineered to provide a secure and stable electrical connection between shore-based power pedestals and your vessel, caravan, or off-grid vehicle. Designed specifically for outdoor and marine use, this heavy-duty cable ensures your onboard systems receive consistent energy without compromising on safety. Featuring a bright, high-visibility yellow jacket, it significantly reduces tripping hazards around docks, campsites, and industrial areas.\u003c\/p\u003e\n\u003cp\u003eConstructed with premium marine-grade materials, this cable delivers a \u003cstrong\u003e25A\u003c\/strong\u003e maximum current capacity to support demanding electrical loads such as battery chargers, air conditioning units, and heavy-duty appliances. *Note typical de-rating factors apply to maximum current capacities under continuous load or elevated temperatures.\u003c\/p\u003e\n\u003ch3\u003eEngineered to Professional CEE Standards\u003c\/h3\u003e\n\u003cp\u003eSafety is paramount when transferring mains electricity in wet or outdoor environments. This shore power cord is built to international CEE (IEC 60309) specifications, featuring a standard 3-pin configuration that ensures a properly grounded, single-phase connection. The moulded male plug and female connector provide exceptional resistance to moisture and dust, keeping your electrical contacts clean and secure over years of frequent use.\u003c\/p\u003e\n\u003cp\u003eFor additional protection against the elements, the female connector includes an integrated weather-resistant dust cap. This keeps the terminals effectively shielded from saltwater spray, dirt, and debris when the cable is unplugged and stored away.\u003c\/p\u003e\n\u003ch3\u003eBuilt Tough for Australian Conditions\u003c\/h3\u003e\n\u003cp\u003eAustralian marine and outback environments subject equipment to extreme ultraviolet radiation, high humidity, and physical abrasion. The outer jacket of this \u003cstrong\u003e15m\u003c\/strong\u003e power cord is highly UV-stabilised and water-resistant, mitigating the cracking and degradation commonly seen in generic outdoor extension leads. Its excellent flexibility makes it easy to coil and store, even in colder weather, without kinking or retaining permanent bends.\u003c\/p\u003e\n\u003ch3\u003eSeamless System Integration\u003c\/h3\u003e\n\u003cp\u003eWhile compatible with standard CEE power pedestals, this cable is perfectly matched to high-quality shore power inlets, including Victron Energy stainless steel and polyamide models. Pairing this cable with a premium inlet creates a watertight, low-resistance circuit that protects your onboard electronics from voltage drops and electrical faults. This is an essential upgrade for any serious marine or mobile energy system.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-visibility yellow outer jacket reduces tripping risks and improves site safety.\u003c\/li\u003e\n\u003cli\u003eRobust CEE-standard 3-pin male plug and female connector for secure, grounded connections.\u003c\/li\u003e\n\u003cli\u003eRated for \u003cstrong\u003e25A\u003c\/strong\u003e maximum current to handle high-demand onboard appliances.\u003c\/li\u003e\n\u003cli\u003eMarine-grade, UV-stabilised, and water-resistant outer jacket built for longevity.\u003c\/li\u003e\n\u003cli\u003eFlexible construction ensures easy deployment and neat coiling for storage.\u003c\/li\u003e\n\u003cli\u003eIntegrated protective cap shields female terminals from moisture and dirt when not in use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eUpgrade Your Power Connection Today\u003c\/h3\u003e\n\u003cp\u003eRelying on standard household extension cords for marine or RV applications can lead to voltage drops, overheating, and serious safety hazards. Equip your vessel or vehicle with the \u003cstrong\u003eVictron 15m 25A\/250Vac Shore Power Cord\u003c\/strong\u003e to ensure safe, compliant, and highly efficient energy transfer wherever you plug in. Invest in professional-grade cabling to protect your onboard systems and enjoy complete peace of mind on your next journey.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCurrent Rating (A)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e25A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eVoltage Rating (VAC)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003ePlug Type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eMoulded IEC 60309 2p+E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003ePlug Colour\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eBlue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eConnector Type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eMoulded IEC 60309 3-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eConnector Colour\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eBlack \/ Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eLED light and protection cap on female connector\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCable Type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eH07BQ-F 3x 4.00 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCable Colour\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eYellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCable Length (m)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCable Size (mm²)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e4.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight (kg)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCE Certified\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364416909595,"sku":"VIC-SHP304001500","price":324.95,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/VIC-SHP304001500-01.jpg?v=1781659092"},{"product_id":"victron-shore-power-cord-25m-16a-250vac-3x2-5sqmm","title":"Victron Energy - 16A\/250Vac Shore Power Cord - 25m","description":"\u003ch2\u003eVictron 25m 16A\/250Vac Shore Power Cord: Reliable Energy Transfer for Marine and RV Systems\u003c\/h2\u003e\n\u003ch3\u003eHigh-Visibility Shore Power for Demanding Environments\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eVictron 25m 16A\/250Vac Shore Power Cord\u003c\/strong\u003e is engineered to provide a secure and stable electrical connection between shore-based power pedestals and your vessel, caravan, or off-grid vehicle. Designed specifically for outdoor and marine use, this heavy-duty cable ensures your onboard systems receive consistent energy without compromising on safety. Featuring a bright, high-visibility yellow jacket, it significantly reduces tripping hazards around docks, campsites, and industrial areas.\u003c\/p\u003e\n\u003cp\u003eConstructed with premium marine-grade materials, this cable delivers a \u003cstrong\u003e16A\u003c\/strong\u003e maximum current capacity to support demanding electrical loads such as battery chargers, air conditioning units, and heavy-duty appliances. *Note typical de-rating factors apply to maximum current capacities under continuous load or elevated temperatures.\u003c\/p\u003e\n\u003ch3\u003eEngineered to Professional CEE Standards\u003c\/h3\u003e\n\u003cp\u003eSafety is paramount when transferring mains electricity in wet or outdoor environments. This shore power cord is built to international CEE (IEC 60309) specifications, featuring a standard 3-pin configuration that ensures a properly grounded, single-phase connection. The moulded male plug and female connector provide exceptional resistance to moisture and dust, keeping your electrical contacts clean and secure over years of frequent use.\u003c\/p\u003e\n\u003cp\u003eFor additional protection against the elements, the female connector includes an integrated weather-resistant dust cap. This keeps the terminals effectively shielded from saltwater spray, dirt, and debris when the cable is unplugged and stored away. Features an ergonomic yellow handle on the female connector for improved grip and ease of handling in wet conditions.\u003c\/p\u003e\n\u003ch3\u003eBuilt Tough for Australian Conditions\u003c\/h3\u003e\n\u003cp\u003eAustralian marine and outback environments subject equipment to extreme ultraviolet radiation, high humidity, and physical abrasion. The outer jacket of this \u003cstrong\u003e25m\u003c\/strong\u003e power cord is highly UV-stabilised and water-resistant, mitigating the cracking and degradation commonly seen in generic outdoor extension leads. Its excellent flexibility makes it easy to coil and store, even in colder weather, without kinking or retaining permanent bends.\u003c\/p\u003e\n\u003ch3\u003eSeamless System Integration\u003c\/h3\u003e\n\u003cp\u003eWhile compatible with standard CEE power pedestals, this cable is perfectly matched to high-quality shore power inlets, including Victron Energy stainless steel and polyamide models. Pairing this cable with a premium inlet creates a watertight, low-resistance circuit that protects your onboard electronics from voltage drops and electrical faults. This is an essential upgrade for any serious marine or mobile energy system.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-visibility yellow outer jacket reduces tripping risks and improves site safety.\u003c\/li\u003e\n\u003cli\u003eRobust CEE-standard 3-pin male plug and female connector for secure, grounded connections.\u003c\/li\u003e\n\u003cli\u003eRated for \u003cstrong\u003e16A\u003c\/strong\u003e maximum current to handle high-demand onboard appliances.\u003c\/li\u003e\n\u003cli\u003eMarine-grade, UV-stabilised, and water-resistant outer jacket built for longevity.\u003c\/li\u003e\n\u003cli\u003eFlexible construction ensures easy deployment and neat coiling for storage.\u003c\/li\u003e\n\u003cli\u003eIntegrated protective cap shields female terminals from moisture and dirt when not in use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eUpgrade Your Power Connection Today\u003c\/h3\u003e\n\u003cp\u003eRelying on standard household extension cords for marine or RV applications can lead to voltage drops, overheating, and serious safety hazards. Equip your vessel or vehicle with the \u003cstrong\u003eVictron 25m 16A\/250Vac Shore Power Cord\u003c\/strong\u003e to ensure safe, compliant, and highly efficient energy transfer wherever you plug in. Invest in professional-grade cabling to protect your onboard systems and enjoy complete peace of mind on your next journey.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCurrent Rating (A)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e16A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eVoltage Rating (VAC)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003ePlug Type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eMoulded IEC 60309 2p+E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003ePlug Colour\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eBlue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eConnector Type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eMoulded IEC 60309 3-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eConnector Colour\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eBlack \/ Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eLED light and protection cap on female connector\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCable Type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eH07BQ-F 3x 2.50mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCable Colour\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eYellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCable Length (m)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCable Size (mm²)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e2.50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight (kg)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e4.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCE Certified\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364417073435,"sku":"VIC-SHP302502500","price":324.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/VIC-SHP302502500-01.jpg?v=1781659091"},{"product_id":"victron-shore-power-cord-25m-32a-250vac-3x6sqmm","title":"Victron Energy - 32A\/250Vac Shore Power Cord - 25m","description":"\u003ch2\u003eVictron 25m 32A Shore Power Cord: Reliable Energy Transfer for Marine and RV Systems\u003c\/h2\u003e\n\u003ch3\u003eHigh-Visibility Shore Power for Demanding Environments\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eVictron 25m 32A Shore Power Cord\u003c\/strong\u003e is engineered to provide a secure and stable electrical connection between shore-based power pedestals and your vessel, caravan, or off-grid vehicle. Designed specifically for outdoor and marine use, this heavy-duty cable ensures your onboard systems receive consistent energy without compromising on safety. Featuring a bright, high-visibility yellow jacket, it significantly reduces tripping hazards around docks, campsites, and industrial areas.\u003c\/p\u003e\n\u003cp\u003eConstructed with premium marine-grade materials, this cable delivers a \u003cstrong\u003e32A\u003c\/strong\u003e maximum current capacity to support demanding electrical loads such as battery chargers, air conditioning units, and heavy-duty appliances. *Note typical de-rating factors apply to maximum current capacities under continuous load or elevated temperatures.\u003c\/p\u003e\n\u003ch3\u003eEngineered to Professional CEE Standards\u003c\/h3\u003e\n\u003cp\u003eSafety is paramount when transferring mains electricity in wet or outdoor environments. This shore power cord is built to international CEE (IEC 60309) specifications, featuring a standard 3-pin configuration that ensures a properly grounded, single-phase connection. The moulded male plug and female connector provide exceptional resistance to moisture and dust, keeping your electrical contacts clean and secure over years of frequent use.\u003c\/p\u003e\n\u003cp\u003eFor additional protection against the elements, the female connector includes an integrated weather-resistant dust cap. This keeps the terminals effectively shielded from saltwater spray, dirt, and debris when the cable is unplugged and stored away. The integrated locking ring on the female connector provides an extra layer of security, reducing the risk of accidental disconnections during heavy vessel movement or adverse weather.\u003c\/p\u003e\n\u003ch3\u003eBuilt Tough for Australian Conditions\u003c\/h3\u003e\n\u003cp\u003eAustralian marine and outback environments subject equipment to extreme ultraviolet radiation, high humidity, and physical abrasion. The outer jacket of this \u003cstrong\u003e25m\u003c\/strong\u003e power cord is highly UV-stabilised and water-resistant, mitigating the cracking and degradation commonly seen in generic outdoor extension leads. Its excellent flexibility makes it easy to coil and store, even in colder weather, without kinking or retaining permanent bends.\u003c\/p\u003e\n\u003ch3\u003eSeamless System Integration\u003c\/h3\u003e\n\u003cp\u003eWhile compatible with standard CEE power pedestals, this cable is perfectly matched to high-quality shore power inlets, including Victron Energy stainless steel and polyamide models. Pairing this cable with a premium inlet creates a watertight, low-resistance circuit that protects your onboard electronics from voltage drops and electrical faults. This is an essential upgrade for any serious marine or mobile energy system.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-visibility yellow outer jacket reduces tripping risks and improves site safety.\u003c\/li\u003e\n\u003cli\u003eRobust CEE-standard 3-pin male plug and female connector for secure, grounded connections.\u003c\/li\u003e\n\u003cli\u003eRated for \u003cstrong\u003e32A\u003c\/strong\u003e maximum current to handle high-demand onboard appliances.\u003c\/li\u003e\n\u003cli\u003eMarine-grade, UV-stabilised, and water-resistant outer jacket built for longevity.\u003c\/li\u003e\n\u003cli\u003eFlexible construction ensures easy deployment and neat coiling for storage.\u003c\/li\u003e\n\u003cli\u003eIntegrated protective cap shields female terminals from moisture and dirt when not in use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eUpgrade Your Power Connection Today\u003c\/h3\u003e\n\u003cp\u003eRelying on standard household extension cords for marine or RV applications can lead to voltage drops, overheating, and serious safety hazards. Equip your vessel or vehicle with the \u003cstrong\u003eVictron 25m 32A Shore Power Cord\u003c\/strong\u003e to ensure safe, compliant, and highly efficient energy transfer wherever you plug in. Invest in professional-grade cabling to protect your onboard systems and enjoy complete peace of mind on your next journey.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCurrent Rating (A)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e32A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eVoltage Rating (VAC)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003ePlug Type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eMoulded IEC 60309 2p+E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003ePlug Colour\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eBlue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eConnector Type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eMoulded IEC 60309 3-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eConnector Colour\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eBlack \/ Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eLED light and protection cap on female connector\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCable Type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eH07BQ-F 3x 6.00mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCable Colour\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eYellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCable Length (m)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCable Size (mm²)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e6.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight (kg)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e10.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCE Certified\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364417204507,"sku":"VIC-SHP306002500","price":609.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/VIC-SHP306002500-01.jpg?v=1781659092"},{"product_id":"victron-shore-power-inlet-stainless-with-cover-16a","title":"Victron Energy - 16A\/250Vac CEE Stainless Steel Shore Power Inlet with Cover","description":"\u003ch2\u003eRobust and Reliable Mains Power Connection for Mobile Environments\u003c\/h2\u003e\n\u003ch3\u003ePremium 240V Shore Power Socket for Marine and RV Applications\u003c\/h3\u003e\n\u003cp\u003eEstablishing a safe and stable connection to mains electricity is critical for any mobile energy setup. The \u003cstrong\u003eVictron 16A\/250Vac CEE Stainless Steel Shore Power Inlet\u003c\/strong\u003e is engineered to provide a secure and highly durable \u003cstrong\u003e240V shore power socket\u003c\/strong\u003e for boats, caravans, and off-grid vehicles. Constructed from high-grade, marine-ready stainless steel, this \u003cstrong\u003eshore power inlet\u003c\/strong\u003e is designed to resist the severe corrosion and degradation commonly experienced in coastal environments and harsh Australian weather.\u003c\/p\u003e\n\u003cp\u003eStandard domestic plugs or generic plastic inlets are often vulnerable to UV damage, impact cracking, and moisture ingress, which can lead to dangerous electrical faults. By upgrading to a dedicated \u003cstrong\u003emarine shore power inlet\u003c\/strong\u003e, you significantly reduce the risk of high-resistance connections and arcing, ensuring your onboard chargers, inverters, and appliances receive stable power.\u003c\/p\u003e\n\u003ch3\u003eIP56 Weatherproof Rating\u003c\/h3\u003e\n\u003cp\u003eSafety and environmental protection are at the forefront of this design. The unit features an IP56 waterproof rating when closed, protecting the internal terminals from high-pressure water spray, dust, and salt mist. A heavy-duty, spring-loaded stainless steel flip cover securely seals the connection point when the \u003cstrong\u003eboat shore power plug\u003c\/strong\u003e is disconnected, preventing moisture accumulation inside the contacts.\u003c\/p\u003e\n\u003ch3\u003eCEE-Standard Compatibility and Low-Resistance Contact\u003c\/h3\u003e\n\u003cp\u003eBuilt to meet strict IEC 60309 (2P+E) CEE standards, this 16A inlet ensures universal compatibility with standard marine and RV electrical systems. It pairs perfectly with the dedicated \u003cstrong\u003eVictron shore power plug\u003c\/strong\u003e and cable series, creating a watertight, mechanically locking connection that will not accidentally vibrate loose during movement or high winds.\u003c\/p\u003e\n\u003cp\u003eThe internal three-pin male connector is manufactured to maintain a low-resistance contact point. In high-draw environments, such as running air conditioners or heavy-duty battery chargers simultaneously, minimizing electrical resistance is essential to prevent terminal overheating and voltage drop.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConstructed from premium marine-grade stainless steel for maximum corrosion resistance and longevity.\u003c\/li\u003e\n\u003cli\u003eRated for 16A and 250Vac, making it an ideal \u003cstrong\u003e240V shore power socket\u003c\/strong\u003e for Australian applications.\u003c\/li\u003e\n\u003cli\u003eIP56 weatherproof housing with a secure, spring-loaded protective cover to block water and dust.\u003c\/li\u003e\n\u003cli\u003eCEE-standard (IEC 60309) configuration for seamless integration with Victron power cables and connectors.\u003c\/li\u003e\n\u003cli\u003eFour-hole mounting flange for secure, flush surface installation on fiberglass, metal, or timber exteriors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eVersatile Applications for Off-Grid and Mobile Power\u003c\/h3\u003e\n\u003cp\u003eWhether you are outfitting a new vessel or replacing an old, sun-damaged plastic inlet, this stainless steel socket delivers exceptional reliability. It is an outstanding choice for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine Vessels:\u003c\/strong\u003e Yachts, cruisers, and workboats requiring a reliable, corrosion-proof \u003cstrong\u003emarine shore power inlet\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCaravans and Motorhomes:\u003c\/strong\u003e Providing a rugged \u003cstrong\u003ecaravan shore power\u003c\/strong\u003e connection that withstands UV exposure and road vibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-Grid and Tiny Homes:\u003c\/strong\u003e Offering a heavy-duty input point for generator or mains backup connections in remote locations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecialized Vehicles:\u003c\/strong\u003e Food trucks, emergency service vehicles, and mobile workshops that demand consistent daily power cycling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSecure Your Power Supply\u003c\/h3\u003e\n\u003cp\u003eInvest in an electrical connection built to last. Equip your vessel or vehicle with the Victron 16A\/250Vac CEE Stainless Steel Shore Power Inlet to ensure maximum safety, weather resistance, and uninterrupted energy transfer. Order today and experience the peace of mind that comes with professional-grade hardware for your next journey.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCurrent Rating\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eVoltage Rating\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e250 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eIEC 60309, 2p+E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCover\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eSolid Cast 316 Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003ePlug Body\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003ePA6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003ePins\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eBrass, Nickel Plated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWaterproof\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eIP 56\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCE Certified\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e0.34 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOverall Diameter\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eØ87 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCut-Out Diameter\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eØ55 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMounting Hole Centres\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e50 x 50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMounting Hole Diameter\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eØ4.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOverall Length\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e91.7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364417401115,"sku":"VIC-SHP301602000","price":134.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/VIC-SHP301602000-01.jpg?v=1781659090"},{"product_id":"victron-ve-transfer-switch-10kva-1ph-200-250vac","title":"Victron Energy - 200-250VAC 10kVA Single Phase Automatic Transfer Switch","description":"\u003ch2\u003eVictron VE Transfer Switch 10KVA: Automatic AC Source Selection for Critical Power Systems\u003c\/h2\u003e\n\u003ch3\u003eSeamless Power Transition for Off-Grid, Backup, and Mobile Installations\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eVictron VE Transfer Switch 10KVA\u003c\/strong\u003e provides reliable, automatic switching between two independent AC power sources. Designed for single-phase systems operating at 200–250 V AC, it ensures your loads remain powered without manual intervention. This unit is particularly effective in setups where continuity is essential, such as switching between an inverter and shore power, a generator and shore power, or between two separate AC supplies.\u003c\/p\u003e\n\u003cp\u003eUnlike generic transfer switches, the Victron VE Transfer Switch is engineered with a fast, break-before-make mechanism that completes a source transfer within 10–20 ms when closing contacts and 5–20 ms when opening. This rapid response helps protect sensitive electronics from extended interruptions and reduces the risk of equipment resetting during changeover. The integrated auxiliary contact (200–240 V AC, 20 A, cos φ = 1) adds flexibility for signalling external devices, such as a Digital Multi Control panel for generator current-limit control.\u003c\/p\u003e\n\u003ch3\u003eBuilt for Demanding Environments\u003c\/h3\u003e\n\u003cp\u003eHoused in a robust IP54-rated enclosure, this transfer switch resists dust and water spray, making it suitable for installation in engine rooms, outdoor cabinets, and marine environments. The light grey RAL 7035 finish reflects heat and blends into standard electrical panels. A clear viewing window on the front cover allows quick visual status checks without opening the unit, while three bottom-entry cable glands provide secure, strain-relieved cable entry. Inside, colour-coded wiring and clearly labelled terminals for IN1, IN2, and OUT simplify installation and reduce wiring errors.\u003c\/p\u003e\n\u003cp\u003eWith a nominal current rating of 40 A per input and output, the switch supports loads up to 8 kW for electric motors, such as air-conditioning compressors. This makes it a practical choice for caravans, motorhomes, and marine vessels where air-conditioning startup currents are a concern. The low power consumption of just 6 VA on Input 1 and 0 VA on Input 2 minimises standby losses, preserving battery capacity in off-grid systems.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatic break-before-make transfer between two AC sources\u003c\/li\u003e\n\u003cli\u003eFast switching: 10–20 ms (close) and 5–20 ms (open) for minimal disruption\u003c\/li\u003e\n\u003cli\u003eIP54-rated enclosure with clear inspection window and cable glands\u003c\/li\u003e\n\u003cli\u003e40 A continuous rating per input\/output, 8 kW motor load capacity\u003c\/li\u003e\n\u003cli\u003eAuxiliary contact for generator start or external signalling\u003c\/li\u003e\n\u003cli\u003eAdjustable input 1 delay (approx. 10 s) to prevent nuisance switching\u003c\/li\u003e\n\u003cli\u003eCompact dimensions (175 x 215 x 120 mm) and lightweight (1.65 kg)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications Where Reliability Matters\u003c\/h3\u003e\n\u003cp\u003eThis transfer switch is ideal for installations that demand uninterrupted AC power. Common use cases include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCaravans and motorhomes: automatically switch between inverter and shore power when connecting to a campsite supply.\u003c\/li\u003e\n\u003cli\u003eMarine vessels: manage shore power and generator inputs without manual changeover switches.\u003c\/li\u003e\n\u003cli\u003eBackup power systems: integrate with battery inverters and generators for seamless failover during grid outages.\u003c\/li\u003e\n\u003cli\u003eRemote off-grid sites: combine solar inverters with backup generators for extended autonomy.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBy automating source selection, the VE Transfer Switch reduces the risk of operator error, such as back-feeding or leaving a generator running unnecessarily. It also eliminates the need for a separate manual changeover switch, simplifying system design and reducing installation time.\u003c\/p\u003e\n\u003ch3\u003eInstallation and Integration\u003c\/h3\u003e\n\u003cp\u003eThe unit is designed for straightforward integration into Victron Energy systems but is compatible with any AC power source within its voltage and frequency range (50–60 Hz). The adjustable input delay on Input 1 (approximately 10 seconds) allows customisation to match generator warm-up times or avoid transient switching. All terminals are clearly marked, and the DIN rail mounted internal components ensure secure connections even in high-vibration environments.\u003c\/p\u003e\n\u003cp\u003eFor systems with lower power needs, the 5KVA model is also available. However, for larger inverters or multiple high-demand appliances, the 10KVA version provides the necessary headroom to prevent overload and ensure long-term reliability.\u003c\/p\u003e\n\u003ch3\u003eUpgrade Your Power Reliability Today\u003c\/h3\u003e\n\u003cp\u003eWhether you are building a new off-grid system or retrofitting an existing installation, the Victron VE Transfer Switch 10KVA delivers the automatic, dependable source selection your setup needs. Add it to your system now and experience uninterrupted power, wherever you are.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNominal Voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e200 - 250 Vac, single-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNominal Frequency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e50 - 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNominal Current Input 1\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNominal Current Input 2\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNominal Output Current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum Electromotor (Air-Conditioner) Power\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e8 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003ePower Consumption Input 1\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e6 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003ePower Consumption Input 2\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e0 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eTransfer Time By Closing Contacts\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e10 - 20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eTransfer Time By Opening Contacts\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e5 - 20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eContacts Delay Input 1\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eApproximately 10 s (adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eAuxiliary Contact\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e200 - 240 Vac, 20 A, cos phi = 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOperating Temperature\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-5 °C to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum Humidity (Non-Condensing)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eProtection Category\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eIP 54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eColour\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eRAL 7035\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions (mm)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e175 x 215 x 120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight (kg)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e1.65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364454428955,"sku":"VIC-COS230103100","price":539.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/VIC-COS230103100-01.jpg?v=1781658045"},{"product_id":"victron-ve-transfer-switch-5kva-1ph-200-250vac","title":"Victron Energy - 200-250VAC 5kVA Single Phase Automatic Transfer Switch","description":"\u003ch2\u003eVictron VE Transfer Switch 5KVA: Automatic AC Source Selection for Mobile and Off-Grid Power Systems\u003c\/h2\u003e\n\u003ch3\u003eSeamless Power Transfer for Caravans, RVs, and Marine Applications\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eVictron VE Transfer Switch 5KVA\u003c\/strong\u003e provides reliable, automatic switching between two independent AC power sources, ensuring uninterrupted supply to your essential loads. Designed for single-phase 200-250V systems, this unit is a critical component in modern \u003cstrong\u003ecaravan inverter installations\u003c\/strong\u003e, \u003cstrong\u003eRV power management\u003c\/strong\u003e, and \u003cstrong\u003emarine electrical systems\u003c\/strong\u003e where shore power and onboard generation must coexist without manual intervention.\u003c\/p\u003e\n\u003cp\u003eUnlike generic changeover switches that require physical operation, the VE Transfer Switch monitors the primary input and transfers to the secondary source within milliseconds when voltage is lost or falls outside acceptable parameters. This eliminates the risk of dropped loads, protects sensitive electronics from abrupt power interruptions, and simplifies system design for installers and end-users alike.\u003c\/p\u003e\n\u003ch3\u003eEngineered for Demanding Mobile Environments\u003c\/h3\u003e\n\u003cp\u003eHoused in a robust IP54-rated enclosure, the VE Transfer Switch withstands dust, moisture, and vibration typical of \u003cstrong\u003eoff-road caravan setups\u003c\/strong\u003e and \u003cstrong\u003ecoastal marine installations\u003c\/strong\u003e. The compact 175 x 215 x 120 mm footprint and 1.85 kg weight allow flexible mounting in confined equipment bays, while the clear protective viewing window enables quick visual status checks without opening the enclosure.\u003c\/p\u003e\n\u003cp\u003eThree heavy-duty cable glands provide secure, strain-relieved entry for input and output wiring, maintaining the IP54 integrity even in high-humidity or splash-prone environments. Internally, colour-coded terminal blocks and clear circuit identification labels reduce installation time and minimise wiring errors, a practical advantage over unbranded alternatives that often lack such installer-friendly details.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic source selection\u003c\/strong\u003e between shore power, generator, or inverter with no user intervention required\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast transfer time\u003c\/strong\u003e of 10-20 ms (closing contacts) and 5-20 ms (opening contacts) to keep sensitive loads online\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable input delay\u003c\/strong\u003e (approx. 10 seconds) prevents nuisance switching from transient voltage fluctuations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated auxiliary contact\u003c\/strong\u003e (200-240V AC, 20A) for remote signalling or control of external devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP54 weatherproof enclosure\u003c\/strong\u003e with clear viewing window and secure cable glands for harsh environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e20A nominal current rating\u003c\/strong\u003e per input and output, supporting up to 1.3 kW motor loads such as air-conditioners\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow standby consumption\u003c\/strong\u003e of only 6 VA on the primary input, preserving battery capacity in off-grid systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReliable Power Management Without Compromise\u003c\/h3\u003e\n\u003cp\u003eIn typical \u003cstrong\u003ecaravan solar installations\u003c\/strong\u003e, the VE Transfer Switch sits between the inverter\/charger and the AC distribution board, automatically selecting shore power when available and reverting to inverter output when disconnected. This eliminates the need for manual changeover switches that can be forgotten, leading to flattened batteries or tripped circuit breakers. For \u003cstrong\u003egenerator-backed systems\u003c\/strong\u003e, the switch ensures the generator only runs when shore power is absent, reducing fuel consumption and runtime hours.\u003c\/p\u003e\n\u003cp\u003eThe unit’s 20A continuous rating per input makes it suitable for most single-phase caravan and small marine applications, while the 1.3 kW maximum motor load accommodates rooftop air-conditioners and other inductive loads without contactor welding or premature failure. Unlike some budget transfer switches that use undersized relays, the Victron design employs a heavy-duty contactor rated for frequent operation, contributing to long service life in daily-use scenarios.\u003c\/p\u003e\n\u003ch3\u003eInstallation Flexibility and System Integration\u003c\/h3\u003e\n\u003cp\u003eThe VE Transfer Switch integrates seamlessly with Victron MultiPlus and Quattro inverter\/charger systems, but its standalone operation also suits third-party inverters and generators. The adjustable input delay allows installers to fine-tune the switchover timing to match generator warm-up periods or inverter start-up sequences, preventing unnecessary cycling. An auxiliary contact provides a volt-free signal that can trigger remote alarms or interface with monitoring systems such as the Victron Cerbo GX, or signal a Digital Multi Control panel for generator current-limit control.\u003c\/p\u003e\n\u003ch3\u003eWhy Choose the Victron VE Transfer Switch?\u003c\/h3\u003e\n\u003cp\u003eGeneric automatic transfer switches often lack the environmental protection, documentation, and support expected in professional installations. The Victron VE Transfer Switch addresses these gaps with an IP54-rated enclosure, clear internal labelling, and comprehensive technical documentation. This reduces installation time, callbacks, and long-term reliability risks, particularly in mobile applications subject to vibration and temperature extremes.\u003c\/p\u003e\n\u003cp\u003eWith an operating temperature range of -5 °C to +60 °C and 95% non-condensing humidity tolerance, the switch performs reliably across Australia’s diverse climates, from tropical coastal regions to arid outback conditions. The RAL 7035 light-grey finish minimises solar heat absorption, further enhancing thermal performance in exposed mounting locations.\u003c\/p\u003e\n\u003ch3\u003eUpgrade Your Power System with Confidence\u003c\/h3\u003e\n\u003cp\u003eWhether you are building a new \u003cstrong\u003ecaravan electrical system\u003c\/strong\u003e, retrofitting an \u003cstrong\u003eRV with inverter-charger capability\u003c\/strong\u003e, or designing a \u003cstrong\u003emarine AC distribution panel\u003c\/strong\u003e, the Victron VE Transfer Switch 5KVA delivers the automatic, worry-free source selection that modern mobile lifestyles demand. Add this essential component to your installation today and experience the reliability that Victron Energy is known for worldwide.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNominal Voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e200 - 250 Vac, single-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNominal Frequency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e50 - 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNominal Current Input 1\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNominal Current Input 2\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNominal Output Current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum Electromotor (Air-Conditioner) Power\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e1.3 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003ePower Consumption Input 1\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e6 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003ePower Consumption Input 2\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e0 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eTransfer Time by Closing Contacts\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e10 - 20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eTransfer Time by Opening Contacts\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e5 - 20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eContacts Delay Input 1\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eApproximately 10 s (adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eAuxiliary Contact\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e200 - 240 Vac, 20 A, cos phi = 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOperating Temperature\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-5 °C to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum Humidity (Non-Condensing)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMiniature Circuit Breaker (MCB)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eNot included - installation dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEarth Leakage Breakers (RCD)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eNot included - installation dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eProtection Category\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eIP 54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eColour\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eRAL 7035\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions (mm)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e175 x 215 x 120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight (kg)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e1.85\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364454560027,"sku":"VIC-COS230502100","price":424.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/VIC-COS230502100-01.jpg?v=1781658041"},{"product_id":"victron-energy-63a-anti-islanding-box-single-and-three-phase","title":"Victron Energy - 63A - Anti-Islanding Box - Single and Three Phase","description":"\u003ch2\u003eVictron Anti-Islanding Box 63A: Pre-Wired Grid Protection for Single and Three-Phase ESS\u003c\/h2\u003e\n\u003ch3\u003eZiehl UFR1001E Relay, Contactors and Circuit Breaker in One IP65 Enclosure\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eVictron Anti-Islanding Box 63A\u003c\/strong\u003e is a pre-wired hardware disconnect solution for grid-feeding inverter\/charger installations that must meet an external, hardware-based anti-islanding requirement. It houses a \u003cstrong\u003eZiehl UFR1001E\u003c\/strong\u003e voltage and frequency relay together with two in-line contactors and a main circuit breaker in a single \u003cstrong\u003eIP65\u003c\/strong\u003e enclosure, rated up to \u003cstrong\u003e63A per phase\u003c\/strong\u003e for both single-phase and three-phase systems.\u003c\/p\u003e\n\u003cp\u003eThe Ziehl UFR1001E relay continuously monitors grid voltage, frequency, vector shift and rate-of-change-of-frequency (ROCOF), and switches the contactors to disconnect the system from the grid if it detects a condition consistent with a lost grid connection. It is a dual-channel, one-fault-proof design with feedback contacts that monitor the connected contactors, and it ships with trip thresholds pre-set to common grid codes such as VDE-AR-N 4105\/4110, G98 and G99, which can be adjusted and sealed by a qualified installer to suit local requirements.\u003c\/p\u003e\n\u003cp\u003eSome Distribution Network Service Providers require certified external hardware anti-islanding protection in addition to, or instead of, an inverter's built-in software anti-islanding for larger grid-connected systems. This box provides the relay, contactors and breaker as a single ready-to-mount unit rather than requiring each component to be sourced and wired separately. Always confirm the specific requirements of your local network operator before design and installation.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eZiehl UFR1001E voltage and frequency relay\u003c\/strong\u003e, dual-channel and one-fault-proof, with adjustable trip thresholds pre-set to common grid codes (VDE-AR-N 4105\/4110, G98, G99 and others)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo in-line contactors and a main circuit breaker\u003c\/strong\u003e, pre-wired inside the enclosure\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e63A per phase\u003c\/strong\u003e, suitable for single-phase or three-phase systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP65 enclosure\u003c\/strong\u003e for protection against dust and low-pressure water jets\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFeedback-contact monitoring\u003c\/strong\u003e of the connected contactors, with automatic restart attempts if a switch fails to close\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eVictron Part Number\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eRCD000300200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCurrent Rating\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e63A per phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003ePhases\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eSingle-phase or three-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eContents\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eZiehl UFR1001E relay, 2x in-line contactors, main circuit breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEnclosure Protection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eRelay Voltage Monitoring Range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eAC 15-520V phase-neutral \/ AC 15-530V phase-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eRelay Frequency Setting Range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e45.00-65.00Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eRelay Switching Delay\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eAdjustable 0.05-300s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eRelay Standards\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eVDE-AR-N 4105:2018-11, VDE-AR-N 4110:2018-11, G98, G99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEnclosure Dimensions (W x H x D)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eapprox. 449.5 x 278.8 x 147.9mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":53941333459227,"sku":"VIC-RCD000300200","price":1774.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/victron-63a-anti-islanding-box-vic-rcd000300200-1.webp?v=1789382314"},{"product_id":"victron-energy-230v-8000w-isolation-transformer","title":"Victron Energy - 230V - 8000W - Isolation Transformer","description":"\u003ch2\u003eVictron 8000W Isolation Transformer: Marine-Grade Galvanic Protection and Electrical Safety\u003c\/h2\u003e\n\u003ch3\u003eEliminate Shore Power Corrosion Risk with a Fan-Cooled Toroidal Isolation Transformer\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eVictron 8000W Isolation Transformer (230V)\u003c\/strong\u003e completely separates a vessel's AC electrical system from the shore power supply, removing the direct electrical path that causes stray-current corrosion of underwater metals and unsafe earth faults. Shore power is fed to the transformer's primary side and the vessel's AC system connects to the secondary, so there is no electrical continuity between the two, eliminating the need for a separate galvanic isolator.\u003c\/p\u003e\n\u003cp\u003eRated for \u003cstrong\u003e8000W continuous at 35A output\u003c\/strong\u003e, the transformer uses a toroidal core for low noise, compact size and reduced weight compared with a laminated transformer of the same rating. A built-in \u003cstrong\u003esoft start \/ inrush current limiter\u003c\/strong\u003e prevents the shore-side circuit breaker from tripping when the transformer is switched on, and the unit is fan-cooled, with the fan speed temperature-controlled and an overtemperature shutdown for protection.\u003c\/p\u003e\n\u003cp\u003eVictron's isolation transformers convert the input voltage with a \u003cstrong\u003e1:1.05 ratio\u003c\/strong\u003e, boosting a 230V input to a 240V output to compensate for the voltage drop that is common over long shore power cable runs at marinas. The transformer works on 50Hz or 60Hz supplies but, like all Victron isolation transformers, cannot convert between the two frequencies.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplete galvanic isolation\u003c\/strong\u003e between shore power and the vessel's AC system, preventing stray-current corrosion\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e8000W \/ 35A output\u003c\/strong\u003e, with a 1:1.05 ratio boosting a 230V input to 240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eToroidal transformer core\u003c\/strong\u003e for low noise, compact size and reduced weight\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoft start \/ inrush current limiter\u003c\/strong\u003e, preventing shore-side breakers from tripping on start-up\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFan-cooled with temperature-controlled speed\u003c\/strong\u003e and overtemperature protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP21 aluminium enclosure\u003c\/strong\u003e (blue RAL5012), with a removable neutral-earth link and a chassis earth bolt\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation\u003c\/h3\u003e\n\u003cp\u003eThe isolation transformer ships with a hanging bracket for mounting inside a vessel, plus earth-linking jumper wires: one to link the AC output neutral to earth (needed for a downstream GFCI\/RCD to operate correctly), and one to bridge the AC input and output earths together when the vessel is out of the water for winter storage or maintenance. AC input and output cables need a minimum \u003cstrong\u003e6mm² (AWG10)\u003c\/strong\u003e cross-section, connecting via clearly marked L, N and PE screw terminals.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eVictron Part Number\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eITR000802002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eAC Input Voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eAC Output Voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eFrequency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput Current Rating\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e35A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eSoft Start\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eTransformer Type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eToroidal (low noise, low weight), 1:1.05 ratio\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEnclosure\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eAluminium (blue RAL5012)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eProtection Category\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eIP21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMinimum Cable Cross-Section\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e6mm² \/ AWG10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOperating Temperature Range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-20°C to 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eHumidity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eMax 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eSafety Standard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 60076\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions (H x W x D)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e362 x 258 x 243mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e28.17kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":53941333491995,"sku":"VIC-ITR000802002","price":1145.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/victron-8000w-230v-isolation-transformer-vic-itr000802002.webp?v=1789382275"},{"product_id":"victron-energy-115-230v-4500w-jumper-set-input-isolation-transformer","title":"Victron Energy - 115\/230V 4500W - Jumper-Set Input - Isolation Transformer","description":"\u003ch2\u003eVictron 4500W Isolation Transformer: Complete Marine Electrical Safety\u003c\/h2\u003e\n\u003cp\u003eConnecting a boat to shore power brings two problems: galvanic corrosion and grounding safety. The \u003cstrong\u003eVictron 4500W 115\/230V Isolation Transformer\u003c\/strong\u003e eliminates any electrical continuity between AC shore power and the boat. It is essential for safety and eliminates the need for galvanic isolators and polarity alarms.\u003c\/p\u003e\n\u003ch3\u003ePrevent Galvanic Corrosion and Protect Your Hull\u003c\/h3\u003e\n\u003cp\u003eGalvanic corrosion occurs when two dissimilar metals in electrical contact are exposed to an electrically conducting fluid such as seawater or fresh water. Connecting the ground wire of the shore supply to the metal parts of the boat causes it, and it can occur on any boat as soon as a metal part such as the shaft and propeller is in the water. Galvanic corrosion quickly dissolves sacrificial anodes and attacks the shaft, propeller and other immersed metal parts.\u003c\/p\u003e\n\u003cp\u003eThe isolation transformer completely isolates the boat from the shore ground: shore power feeds the primary side of the transformer and the boat is connected to the secondary.\u003c\/p\u003e\n\u003ch3\u003eEnsure Critical Grounding Safety\u003c\/h3\u003e\n\u003cp\u003eLeaving the shore ground disconnected is extremely dangerous, because GFCIs will not work nor will a fuse blow in case of a short circuit to a metal part on the boat. By connecting all metal parts to the neutral output on the secondary side of the transformer, a GFCI will trip or a fuse will blow in case of a short circuit.\u003c\/p\u003e\n\u003ch3\u003e115V or 230V, Set at Installation\u003c\/h3\u003e\n\u003cp\u003eThe AC input and the AC output each need to be configured for 115V or 230V use, using the included jumper wires on the spade terminals above the input and output connectors. It can be used as a 115V to 115V, 230V to 230V, 115V to 230V or 230V to 115V isolation transformer.\u003c\/p\u003e\n\u003ch3\u003eBuilt-In Soft Start\u003c\/h3\u003e\n\u003cp\u003eSoft start is a standard feature of Victron isolation transformers. It prevents the shore power fuse from blowing due to the inrush current of the transformer.\u003c\/p\u003e\n\u003ch3\u003eKey Features and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal Electrical Isolation:\u003c\/strong\u003e No electrical continuity between shore power and the boat.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCorrosion Prevention:\u003c\/strong\u003e Stops the shore ground connection that causes galvanic corrosion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnhanced Safety:\u003c\/strong\u003e GFCIs and fuses keep working on the boat side.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoft Start:\u003c\/strong\u003e Prevents shore power fuses blowing from transformer inrush current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Voltage Handling: 115V or 230V input and output, set with jumper wires.\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eToroidal Transformer:\u003c\/strong\u003e Low noise and low weight, in an aluminium IP21 enclosure with an input circuit breaker.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProtect Your Investment Today\u003c\/h3\u003e\n\u003cp\u003eVictron recommends, for optimal safety, connecting the secondary neutral of the transformer to ground when the boat is out of the water. Fit the Victron 4500W 115\/230V Isolation Transformer for safe shore power wherever you dock.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003ePower Rating\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e4500 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eAC Input Voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e115 or 230 V (set with jumper wires)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eAC Output Voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e115 or 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eFrequency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eRating\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e38 \/ 19 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eSoft Start\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eInput Circuit Breaker\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eTransformer Type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eToroidal (low noise, low weight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEnclosure\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eAluminium (blue RAL 5012)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eProtection Category\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eIP21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eSafety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 60076\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e22.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions (H x W x D)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e362 x 258 x 221 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eModel Code\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eITR040452042\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":54373104386331,"sku":"VIC-ITR040452042","price":777.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/victron-4500w-isolation-transformer-front-vic-itr040452042_f6775a89-7395-446f-8eef-a4c7a8affcd5.webp?v=1792911085"},{"product_id":"victron-energy-115-230v-4500w-auto-isolation-transformer","title":"Victron Energy - 115\/230V 4500W Auto - Isolation Transformer","description":"\u003ch2\u003eVictron 4500W Isolation Transformer Auto: Complete Marine Electrical Safety\u003c\/h2\u003e\n\u003cp\u003eConnecting a boat to shore power brings two problems: galvanic corrosion and grounding safety. The \u003cstrong\u003eVictron 4500W Auto 115\/230V Isolation Transformer\u003c\/strong\u003e eliminates any electrical continuity between AC shore power and the boat. It is essential for safety and eliminates the need for galvanic isolators and polarity alarms.\u003c\/p\u003e\n\u003ch3\u003ePrevent Galvanic Corrosion and Protect Your Hull\u003c\/h3\u003e\n\u003cp\u003eGalvanic corrosion occurs when two dissimilar metals in electrical contact are exposed to an electrically conducting fluid such as seawater or fresh water. Connecting the ground wire of the shore supply to the metal parts of the boat causes it, and it can occur on any boat as soon as a metal part such as the shaft and propeller is in the water. Galvanic corrosion quickly dissolves sacrificial anodes and attacks the shaft, propeller and other immersed metal parts.\u003c\/p\u003e\n\u003cp\u003eThe isolation transformer completely isolates the boat from the shore ground: shore power feeds the primary side of the transformer and the boat is connected to the secondary.\u003c\/p\u003e\n\u003ch3\u003eEnsure Critical Grounding Safety\u003c\/h3\u003e\n\u003cp\u003eLeaving the shore ground disconnected is extremely dangerous, because GFCIs will not work nor will a fuse blow in case of a short circuit to a metal part on the boat. By connecting all metal parts to the neutral output on the secondary side of the transformer, a GFCI will trip or a fuse will blow in case of a short circuit.\u003c\/p\u003e\n\u003ch3\u003eAutomatic 115V or 230V Input Switching\u003c\/h3\u003e\n\u003cp\u003eThis model automatically switches to 115V or 230V supply, depending on input voltage: a supply of 88V to 130V switches it to 115V, and a supply of 185V to 250V switches it to the 230V range. Note that the AC input voltage is raised by a 1:1.05 ratio at the AC output.\u003c\/p\u003e\n\u003ch3\u003eBuilt-In Soft Start\u003c\/h3\u003e\n\u003cp\u003eSoft start is a standard feature of Victron isolation transformers. It prevents the shore power fuse from blowing due to the inrush current of the transformer.\u003c\/p\u003e\n\u003ch3\u003eKey Features and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal Electrical Isolation:\u003c\/strong\u003e No electrical continuity between shore power and the boat.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCorrosion Prevention:\u003c\/strong\u003e Stops the shore ground connection that causes galvanic corrosion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnhanced Safety:\u003c\/strong\u003e GFCIs and fuses keep working on the boat side.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoft Start:\u003c\/strong\u003e Prevents shore power fuses blowing from transformer inrush current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic Input Switching: Detects a 115V or 230V supply and switches by itself.\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eToroidal Transformer:\u003c\/strong\u003e Low noise and low weight, in an aluminium IP21 enclosure with an input circuit breaker.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProtect Your Investment Today\u003c\/h3\u003e\n\u003cp\u003eVictron recommends, for optimal safety, connecting the secondary neutral of the transformer to ground when the boat is out of the water. Fit the Victron 4500W Auto 115\/230V Isolation Transformer for safe shore power wherever you dock.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003ePower Rating\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e4500 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eAC Input Voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e115 \/ 230 V, automatic 115\/230 V switching (88 – 130 V: 115 V; 185 – 250 V: 230 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eAC Output Voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e115 or 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eFrequency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eRating\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e38 \/ 19 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eSoft Start\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eInput Circuit Breaker\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eTransformer Type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eToroidal (low noise, low weight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEnclosure\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eAluminium (blue RAL 5012)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eProtection Category\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eIP21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eSafety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 60076\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e21.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions (H x W x D)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e362 x 258 x 221 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eModel Code\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eITR050452042\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":54373104419099,"sku":"VIC-ITR050452042","price":813.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/victron-isolation-transformer-4500w-front-vic-itr050452042.webp?v=1792911087"},{"product_id":"victron-energy-120v-240v-50a-autotransformer","title":"Victron Energy - 120V\/240V - 50A - Autotransformer","description":"\u003ch2\u003eVictron 50A Autotransformer: Split-Phase Balancing and Voltage Conversion\u003c\/h2\u003e\n\u003ch3\u003eStep-Up, Step-Down and Load Balancing in 120\/240V Systems\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eVictron Autotransformer 120\/240V 50A\u003c\/strong\u003e is a toroidal autotransformer for split-phase 120\/240V installations. Used with a generator or stacked inverters, it balances loads across the two legs: any load unbalance is absorbed by the autotransformer, so a single-phase load can draw more of the available power.\u003c\/p\u003e\n\u003ch3\u003eHow It Solves Real-World Power Problems\u003c\/h3\u003e\n\u003cp\u003eThe autotransformer can also create the voltage a system needs. It can step up by doubling the incoming voltage for split-phase loads, or step down by decreasing the incoming voltage, for example to let a single-phase inverter use both legs of a split-phase generator.\u003c\/p\u003e\n\u003ch3\u003eBuilt-In Safety and Protection Features\u003c\/h3\u003e\n\u003cp\u003eAn integrated \u003cstrong\u003eground relay\u003c\/strong\u003e creates the neutral-to-ground bond and can be controlled by a Victron MultiPlus or Quattro inverter\/charger. If the autotransformer overheats it is disconnected from the supply: the fan runs and a red LED lights when it gets warm, and the MCB trips if it overheats. In case of over current the \u003cstrong\u003e50A two-pole input circuit breaker\u003c\/strong\u003e switches off.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eToroidal transformer design\u003c\/li\u003e\n\u003cli\u003eNeutral current rating of 45A continuous at 40°C, and 55A for 30 minutes\u003c\/li\u003e\n\u003cli\u003eMaximum 240V feed through current of 50A\u003c\/li\u003e\n\u003cli\u003eIntegrated ground relay for inverter neutral bonding\u003c\/li\u003e\n\u003cli\u003eTemperature protection and over current protection\u003c\/li\u003e\n\u003cli\u003eAluminium enclosure with IP21 protection rating\u003c\/li\u003e\n\u003cli\u003eScrew terminals for 35 mm² \/ AWG 2 cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e50A and 100A Models\u003c\/h3\u003e\n\u003cp\u003eVictron makes the autotransformer in 50A and 100A versions. The pass through current is 50A and 100A respectively; the transformers are the same in both models.\u003c\/p\u003e\n\u003ch3\u003eMaximise Your Power System's Potential\u003c\/h3\u003e\n\u003cp\u003eFit the Victron 50A Autotransformer to a 120\/240V split-phase system to balance loads and make full use of your generator or inverter capacity.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eArticle Number\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eITR000100052\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eInput\/Output Voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e120 \/ 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eInput Circuit Breaker\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e50 A, Two Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eFrequency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum 240 V Feed Through Current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNeutral Current, 30 Min\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e55 A @ 40 °C \/ 100 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNeutral Current, Continuous\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e45 A @ 40 °C \/ 100 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eTransformer Type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eToroidal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eElectrical Terminals\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eScrew Terminals 35 mm² \/ AWG 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEnclosure\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eAluminium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eProtection Category\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eIP21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eSafety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 60076\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":54373104451867,"sku":"VIC-ITR000100052","price":677.95,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/victron-autotransformer-120-240v-50a-vic-itr000100052.webp?v=1792911089"}],"url":"https:\/\/www.nbcampingequipment.com.au\/collections\/ac-shore-power.oembed","provider":"NB Camping Equipment","version":"1.0","type":"link"}