{"title":"DC-DC CONVERTERS","description":"","products":[{"product_id":"victron-100a-buck-boost-dc-dc-converter","title":"Victron Energy - 12\/24V - 100A - Buck-Boost DC-DC Converter","description":"\u003ch2\u003eVictron 12\/24V 100A Buck-Boost DC-DC Converter\u003c\/h2\u003e \u003ch3\u003eHigh-Performance Charging for Service Batteries in Vehicles with Smart Alternators\u003c\/h3\u003e \u003cp\u003eThe Victron 12\/24V 100A Buck-Boost DC-DC Converter delivers high-performance charging for 12V or 24V service batteries in vehicles equipped with smart alternators, including those with Euro 5 and Euro 6 engines featuring regenerative braking. This sophisticated converter ensures your auxiliary battery receives a consistent and reliable charge by effectively managing both high and low voltage conditions, eliminating common issues associated with smart alternators.\u003c\/p\u003e \u003ch3\u003eKey Features\u003c\/h3\u003e \u003ch4\u003eVersatile Compatibility\u003c\/h4\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eSupports Multiple Systems:\u003c\/strong\u003e This converter is compatible with 12V, 24V, and 12\/24V systems, allowing you to charge a 12V or 24V auxiliary battery from either a 12V or 24V alternator and starter battery.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003ePre-set Charge Voltage:\u003c\/strong\u003e Guarantees stable charging by regulating high voltages (e.g., Mercedes: 15.4V) and low voltages.\u003c\/li\u003e \u003c\/ul\u003e \u003ch4\u003eIntelligent Design\u003c\/h4\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eEngine Running Detection:\u003c\/strong\u003e Prevents deep discharge of the vehicle's starting battery by detecting when the engine is running. Alternatively, the converter can be activated via programmable inputs (D+, CAN bus, or (+)15 connection).\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eFully Programmable:\u003c\/strong\u003e Easily program the converter using a simple and user-friendly PC application (USB type A male to USB type B male cable required).\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003ePerformance and Safety\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eCharge Current and Input Current Limiter:\u003c\/strong\u003e The output current is regulated by the maximum charge current setting, input current setting, and the converter's maximum operating temperature limit.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eStatus Indication LEDs:\u003c\/strong\u003e Clear visual indicators for input and output status to ensure optimal operation and troubleshooting.\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eApplications\u003c\/h3\u003e \u003cp\u003eIdeal for various applications including:\u003c\/p\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eTrucks, Buses, and RVs:\u003c\/strong\u003e Maintain your service batteries efficiently while traveling.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMarine:\u003c\/strong\u003e Reliable power management for boats with smart alternators.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eOff-Grid and Industrial:\u003c\/strong\u003e Perfect for remote power systems and industrial equipment.\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eUpgrade Your Power System\u003c\/h3\u003e \u003cp\u003eEnsure your vehicle's auxiliary battery is always charged and ready with the Victron 12\/24V 100A Buck-Boost DC-DC Converter. Optimize your power management and prevent battery issues with this versatile and powerful converter.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eOrder yours today and experience seamless battery charging in your vehicle!\u003c\/strong\u003e\u003c\/p\u003e \n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eInput voltage range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e10-30V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage threshold\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e10V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e10-30V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum charge current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e12V: 100A 24V: 50A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eConverter off, LEDs off (power save mode)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e7 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eProgrammable input: 'On' threshold voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026gt; 2V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eProgrammable input: maximum voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e30V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eProgrammable output: voltage if activated\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eV input = Vin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eProgrammable output: maximum current (per pin)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eI input = 1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-25 to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eMax current: up to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e4.1kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e288 x 162 x 95mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364275974427,"sku":"VIC-ORI303100000","price":1674.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/VIC-ORI303100000-01.jpg?v=1781658368"},{"product_id":"victron-24v-to-12v-orion-24-12-60a-non-isolated-ip20-dc-dc-converter","title":"Victron Energy - 24V to 12V - 60A - Orion 24\/12-60A Non-Isolated IP20 - DC-DC Converter","description":"\u003ch2\u003eVictron 24V to 12V Orion 24\/12-60A Non-Isolated IP20 DC-DC Converter\u003c\/h2\u003e\n\u003ch3\u003eProfessional-Grade DC-DC Conversion for Demanding Mobile and Off-Grid Systems\u003c\/h3\u003e\n\u003cp\u003eEngineered for reliability in the toughest environments, the Victron Orion 24\/12-60A DC-DC converter delivers clean, stable power conversion with industry-leading efficiency. When stepping 24V down to 12V, this non-isolated converter ensures your sensitive electronics and battery banks receive precisely regulated power, reducing the risk of voltage drop and equipment malfunction common with lower-grade alternatives.\u003c\/p\u003e\n\u003cp\u003eUnlike generic converters that struggle with fluctuating input voltages, the Orion maintains consistent output even under variable loads, making it the preferred choice for professional installers and system integrators across Australia. Its robust design and advanced protection features safeguard your investment, providing peace of mind for critical applications where power stability is non-negotiable.\u003c\/p\u003e\n\u003ch3\u003eAdvanced Power Conversion Technology\u003c\/h3\u003e\n\u003cp\u003eAt the core of the Orion is a high-frequency switchmode design that achieves up to 95% conversion efficiency, minimising wasted energy and heat generation. This not only reduces thermal stress on the unit but also preserves precious battery capacity in off-grid setups. The result is cooler operation, longer service life, and more usable power for your loads.\u003c\/p\u003e\n\u003cp\u003eWith an input voltage range of 18-35V, the converter handles the wide voltage swings typical of alternator charging and battery discharge cycles without interruption. An intelligent under-voltage shutdown protects your source battery from deep discharge, automatically restarting when voltage recovers to a safe level.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Efficiency up to 95%\u003c\/strong\u003e – reduces energy loss and heat buildup for reliable long-term operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Input Voltage Range (18-35V)\u003c\/strong\u003e – accommodates real-world voltage fluctuations without performance drop\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous Output Current of 60A\u003c\/strong\u003e – powers demanding loads with headroom for surges\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact IP20 Aluminium Enclosure\u003c\/strong\u003e – durable and lightweight, with integrated mounting points for secure installation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Against Under-Voltage, Over-Temperature, and Short Circuit\u003c\/strong\u003e – safeguards both the converter and connected equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote On-Off Capability\u003c\/strong\u003e – enables system-level control without high-current switching\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eBuilt for Australian Conditions\u003c\/h3\u003e\n\u003cp\u003eFrom the corrugations of the Outback to the corrosive salt air of coastal waters, the Orion is built to endure. Its anodised aluminium chassis resists corrosion while acting as an effective heat sink. The IP20 rating suits protected installations inside vehicles, vessels, and equipment enclosures, where it is shielded from direct weather but still benefits from passive or active cooling.\u003c\/p\u003e\n\u003cp\u003eAll DC connections are engineered for low resistance and high current handling, using Double Faston tabs 6.3 mm terminals that accept appropriately sized lugs for minimal voltage drop. This attention to detail ensures maximum power transfer and reduces the risk of hot connections that plague inferior products.\u003c\/p\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe Orion 24\/12-60A converter excels wherever reliable DC voltage conversion is required:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine and Boating\u003c\/strong\u003e – power 12V electronics from a 24V house bank, or charge a 12V starter battery from a 24V alternator\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecreational Vehicles and Caravans\u003c\/strong\u003e – run 12V appliances from a 24V system, or maintain auxiliary batteries while driving\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-Grid Solar Systems\u003c\/strong\u003e – interface between different battery voltages or power 12V equipment from a 24V battery bank\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial and Mobile Plant\u003c\/strong\u003e – provide stable voltage for control systems, communication gear, and monitoring equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmergency Services and Fleet Vehicles\u003c\/strong\u003e – ensure critical 12V or 24V loads remain operational regardless of vehicle voltage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Professionals Choose Victron Orion\u003c\/h3\u003e\n\u003cp\u003eGeneric DC-DC converters often fail prematurely due to inadequate cooling, poor voltage regulation, or lack of protection features. The Orion addresses these risks with a proven design backed by Victron's decades of power electronics expertise. Its conservative component ratings and comprehensive testing mean it performs reliably year after year, reducing downtime and replacement costs.\u003c\/p\u003e\n\u003cp\u003eInstallation is straightforward, with clear terminal markings and included accessories where applicable. The compact footprint allows mounting in tight spaces, while the lightweight construction minimises added weight to vehicles and vessels.\u003c\/p\u003e\n\u003ch3\u003ePower Your System with Confidence\u003c\/h3\u003e\n\u003cp\u003eEquip your setup with the Victron Orion 24\/12-60A DC-DC converter and experience the difference professional-grade power conversion makes. Whether you're upgrading an existing system or building from scratch, this converter delivers the performance and durability needed for Australia's harshest environments. Add it to your power system today and ensure your critical loads always receive clean, stable voltage.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eOrion 24\/12-60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eInput voltage range (V)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e18-35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage shutdown (V)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage restart (V)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage adjustable with potentiometer\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage (V)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e13.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEfficiency (%)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eSuitable to buffer-charge a battery\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCan be connected in parallel\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eContinuous output current (A)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMax. Output current (A)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eFan assisted cooling (temp. controlled)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eGalvanic isolation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOff load current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 20mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eRemote on-off\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOperating temperature range (derate 3% per °C above 40°C)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-20 to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDC connection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eDouble Faston tabs 6.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight kg (lbs)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e0.85 (1.9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions hxwxd in mm (hxwxd in inches)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e65x88x185 (2.6x3.5x7.3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards: Safety Emission Immunity Automotive Directive\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 60950 EN 61000-6-3, EN 55014-1 EN 61000-6-2, EN 61000-6-1, EN 55014-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364307792155,"sku":"VIC-ORI241260020","price":144.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/VIC-ORI241260020-01.jpg?v=1781658357"},{"product_id":"victron-24v-to-12v-orion-24-12-80a-non-isolated-ip20-dc-dc-converter","title":"Victron Energy - 24V to 12V - 80A - Orion 24\/12-80A Non-Isolated IP20 - DC-DC Converter","description":"\u003ch2\u003eVictron 24V to 12V Orion 24\/12-80A Non-Isolated IP20 DC-DC Converter\u003c\/h2\u003e\n\u003ch3\u003eProfessional-Grade DC-DC Conversion for Demanding Mobile and Off-Grid Systems\u003c\/h3\u003e\n\u003cp\u003eEngineered for reliability in the toughest environments, the Victron Orion 24\/12-80A DC-DC converter delivers clean, stable power conversion with industry-leading efficiency. When stepping 24V down to 12V, this non-isolated converter ensures your sensitive electronics and battery banks receive precisely regulated power, reducing the risk of voltage drop and equipment malfunction common with lower-grade alternatives.\u003c\/p\u003e\n\u003cp\u003eUnlike generic converters that struggle with fluctuating input voltages, the Orion maintains consistent output even under variable loads, making it the preferred choice for professional installers and system integrators across Australia. Its robust design and advanced protection features safeguard your investment, providing peace of mind for critical applications where power stability is non-negotiable.\u003c\/p\u003e\n\u003ch3\u003eAdvanced Power Conversion Technology\u003c\/h3\u003e\n\u003cp\u003eAt the core of the Orion is a high-frequency switchmode design that achieves up to 92% conversion efficiency, minimising wasted energy and heat generation. This not only reduces thermal stress on the unit but also preserves precious battery capacity in off-grid setups. The result is cooler operation, longer service life, and more usable power for your loads.\u003c\/p\u003e\n\u003cp\u003eWith an input voltage range of 18-35V, the converter handles the wide voltage swings typical of alternator charging and battery discharge cycles without interruption. An intelligent under-voltage shutdown protects your source battery from deep discharge, automatically restarting when voltage recovers to a safe level.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Efficiency up to 92%\u003c\/strong\u003e – reduces energy loss and heat buildup for reliable long-term operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Input Voltage Range (18-35V)\u003c\/strong\u003e – accommodates real-world voltage fluctuations without performance drop\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous Output Current of 80A\u003c\/strong\u003e – powers demanding loads with headroom for surges\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact IP20 Aluminium Enclosure\u003c\/strong\u003e – durable and lightweight, with integrated mounting points for secure installation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Against Under-Voltage, Over-Temperature, and Short Circuit\u003c\/strong\u003e – safeguards both the converter and connected equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote On-Off Capability\u003c\/strong\u003e – enables system-level control without high-current switching\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eParallel Connection Support\u003c\/strong\u003e – scale output current by linking multiple units for larger systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable Output Voltage\u003c\/strong\u003e – fine-tune voltage to match specific battery chemistries or load requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eBuilt for Australian Conditions\u003c\/h3\u003e\n\u003cp\u003eFrom the corrugations of the Outback to the corrosive salt air of coastal waters, the Orion is built to endure. Its anodised aluminium chassis resists corrosion while acting as an effective heat sink. The IP20 rating suits protected installations inside vehicles, vessels, and equipment enclosures, where it is shielded from direct weather but still benefits from passive or active cooling.\u003c\/p\u003e\n\u003cp\u003eAll DC connections are engineered for low resistance and high current handling, using M6 bolt terminals that accept appropriately sized lugs for minimal voltage drop. This attention to detail ensures maximum power transfer and reduces the risk of hot connections that plague inferior products.\u003c\/p\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe Orion 24\/12-80A converter excels wherever reliable DC voltage conversion is required:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine and Boating\u003c\/strong\u003e – power 12V electronics from a 24V house bank, or charge a 12V starter battery from a 24V alternator\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecreational Vehicles and Caravans\u003c\/strong\u003e – run 12V appliances from a 24V system, or maintain auxiliary batteries while driving\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-Grid Solar Systems\u003c\/strong\u003e – interface between different battery voltages or power 12V equipment from a 24V battery bank\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial and Mobile Plant\u003c\/strong\u003e – provide stable voltage for control systems, communication gear, and monitoring equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmergency Services and Fleet Vehicles\u003c\/strong\u003e – ensure critical 12V or 24V loads remain operational regardless of vehicle voltage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Professionals Choose Victron Orion\u003c\/h3\u003e\n\u003cp\u003eGeneric DC-DC converters often fail prematurely due to inadequate cooling, poor voltage regulation, or lack of protection features. The Orion addresses these risks with a proven design backed by Victron's decades of power electronics expertise. Its conservative component ratings and comprehensive testing mean it performs reliably year after year, reducing downtime and replacement costs.\u003c\/p\u003e\n\u003cp\u003eInstallation is straightforward, with clear terminal markings and included accessories where applicable. The compact footprint allows mounting in tight spaces, while the lightweight construction minimises added weight to vehicles and vessels.\u003c\/p\u003e\n\u003ch3\u003ePower Your System with Confidence\u003c\/h3\u003e\n\u003cp\u003eEquip your setup with the Victron Orion 24\/12-80A DC-DC converter and experience the difference professional-grade power conversion makes. Whether you're upgrading an existing system or building from scratch, this converter delivers the performance and durability needed for Australia's harshest environments. Add it to your power system today and ensure your critical loads always receive clean, stable voltage.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eOrion 24\/12-80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eInput voltage range (V)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e18-35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage shutdown (V)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage restart (V)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage adjustable with potentiometer\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage (V)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eAdjustable 10-15V F set 13.2V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEfficiency (%)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e92\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eSuitable to buffer-charge a battery\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCan be connected in parallel\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eContinuous output current (A)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMax. Output current (A)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eFan assisted cooling (temp. controlled)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eGalvanic isolation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOff load current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 20mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eRemote on-off\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOperating temperature range (derate 3% per °C above 40°C)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-20 to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDC connection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eM6 bolts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight kg (lbs)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e0.9 (2.0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions hxwxd in mm (hxwxd in inches)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e65x88x195 (2.6x3.5x7.7)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards: Safety Emission Immunity Automotive Directive\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 60950 EN 61000-6-3, EN 55014-1 EN 61000-6-2, EN 61000-6-1, EN 55014-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364308021531,"sku":"VIC-ORI241280020","price":154.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/VIC-ORI241280020-01.jpg?v=1781658361"},{"product_id":"victron-24v-to-12v-orion-24-12-80a-non-isolated-ip20-dc-dc-converter-w-binding-posts","title":"Victron Energy - 24V to 12V - 80A - Orion 24\/12-80A Non-Isolated IP20 - DC-DC Converter - Binding Post","description":"\u003ch2\u003eVictron 24V to 12V Orion 24\/12-80A Non-Isolated IP20 DC-DC Converter\u003c\/h2\u003e\n\u003ch3\u003eProfessional-Grade DC-DC Conversion for Demanding Mobile and Off-Grid Systems\u003c\/h3\u003e\n\u003cp\u003eEngineered for reliability in the toughest environments, the Victron Orion 24\/12-80A DC-DC converter delivers clean, stable power conversion with industry-leading efficiency. When stepping 24V down to 12V, this non-isolated converter ensures your sensitive electronics and battery banks receive precisely regulated power, reducing the risk of voltage drop and equipment malfunction common with lower-grade alternatives.\u003c\/p\u003e\n\u003cp\u003eUnlike generic converters that struggle with fluctuating input voltages, the Orion maintains consistent output even under variable loads, making it the preferred choice for professional installers and system integrators across Australia. Its robust design and advanced protection features safeguard your investment, providing peace of mind for critical applications where power stability is non-negotiable.\u003c\/p\u003e\n\u003ch3\u003eAdvanced Power Conversion Technology\u003c\/h3\u003e\n\u003cp\u003eAt the core of the Orion is a high-frequency switchmode design that achieves up to 92% conversion efficiency, minimising wasted energy and heat generation. This not only reduces thermal stress on the unit but also preserves precious battery capacity in off-grid setups. The result is cooler operation, longer service life, and more usable power for your loads.\u003c\/p\u003e\n\u003cp\u003eWith an input voltage range of 18-35V, the converter handles the wide voltage swings typical of alternator charging and battery discharge cycles without interruption. An intelligent under-voltage shutdown protects your source battery from deep discharge, automatically restarting when voltage recovers to a safe level.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Efficiency up to 92%\u003c\/strong\u003e – reduces energy loss and heat buildup for reliable long-term operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Input Voltage Range (18-35V)\u003c\/strong\u003e – accommodates real-world voltage fluctuations without performance drop\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous Output Current of 80A\u003c\/strong\u003e – powers demanding loads with headroom for surges\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact IP20 Aluminium Enclosure\u003c\/strong\u003e – durable and lightweight, with integrated mounting points for secure installation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Against Under-Voltage, Over-Temperature, and Short Circuit\u003c\/strong\u003e – safeguards both the converter and connected equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote On-Off Capability\u003c\/strong\u003e – enables system-level control without high-current switching\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eParallel Connection Support\u003c\/strong\u003e – scale output current by linking multiple units for larger systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable Output Voltage\u003c\/strong\u003e – fine-tune voltage to match specific battery chemistries or load requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eBuilt for Australian Conditions\u003c\/h3\u003e\n\u003cp\u003eFrom the corrugations of the Outback to the corrosive salt air of coastal waters, the Orion is built to endure. Its anodised aluminium chassis resists corrosion while acting as an effective heat sink. The IP20 rating suits protected installations inside vehicles, vessels, and equipment enclosures, where it is shielded from direct weather but still benefits from passive or active cooling.\u003c\/p\u003e\n\u003cp\u003eAll DC connections are engineered for low resistance and high current handling, using M6 bolt terminals that accept appropriately sized lugs for minimal voltage drop. This attention to detail ensures maximum power transfer and reduces the risk of hot connections that plague inferior products.\u003c\/p\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe Orion 24\/12-80A converter excels wherever reliable DC voltage conversion is required:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine and Boating\u003c\/strong\u003e – power 12V electronics from a 24V house bank, or charge a 12V starter battery from a 24V alternator\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecreational Vehicles and Caravans\u003c\/strong\u003e – run 12V appliances from a 24V system, or maintain auxiliary batteries while driving\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-Grid Solar Systems\u003c\/strong\u003e – interface between different battery voltages or power 12V equipment from a 24V battery bank\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial and Mobile Plant\u003c\/strong\u003e – provide stable voltage for control systems, communication gear, and monitoring equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmergency Services and Fleet Vehicles\u003c\/strong\u003e – ensure critical 12V or 24V loads remain operational regardless of vehicle voltage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Professionals Choose Victron Orion\u003c\/h3\u003e\n\u003cp\u003eGeneric DC-DC converters often fail prematurely due to inadequate cooling, poor voltage regulation, or lack of protection features. The Orion addresses these risks with a proven design backed by Victron's decades of power electronics expertise. Its conservative component ratings and comprehensive testing mean it performs reliably year after year, reducing downtime and replacement costs.\u003c\/p\u003e\n\u003cp\u003eInstallation is straightforward, with clear terminal markings and included accessories where applicable. The compact footprint allows mounting in tight spaces, while the lightweight construction minimises added weight to vehicles and vessels.\u003c\/p\u003e\n\u003ch3\u003ePower Your System with Confidence\u003c\/h3\u003e\n\u003cp\u003eEquip your setup with the Victron Orion 24\/12-80A DC-DC converter and experience the difference professional-grade power conversion makes. Whether you're upgrading an existing system or building from scratch, this converter delivers the performance and durability needed for Australia's harshest environments. Add it to your power system today and ensure your critical loads always receive clean, stable voltage.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eOrion 24\/12-80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eInput voltage range (V)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e18-35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage shutdown (V)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage restart (V)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage adjustable with potentiometer\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage (V)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eAdjustable 10-15V, factory set 13.2V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEfficiency (%)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e92\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eSuitable to buffer-charge a battery\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCan be connected in parallel\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eContinuous output current (A)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMax. Output current (A)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eFan assisted cooling (temp. controlled)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eGalvanic isolation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOff load current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 20mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eRemote on-off\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOperating temperature range (derate 3% per °C above 40°C)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-20 to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDC connection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eM6 bolts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight kg (lbs)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e0.9 (2.0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions hxwxd in mm (hxwxd in inches)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e65x88x195 (2.6x3.5x7.7)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards: Safety Emission Immunity Automotive Directive\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 60950 EN 61000-6-3, EN 55014-1 EN 61000-6-2, EN 61000-6-1, EN 55014-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364308152603,"sku":"VIC-ORI241280030","price":174.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/VIC-ORI241280030-01.jpg?v=1781658351"},{"product_id":"victron-25a-buck-boost-dc-dc-converter","title":"Victron Energy - 12\/24V - 25A - Buck-Boost DC-DC Converter","description":"\u003ch2\u003eVictron 12\/24V 25A Buck-Boost DC-DC Converter\u003c\/h2\u003e \u003ch3\u003eCharge Your Service Battery Efficiently in Vehicles with Smart Alternators\u003c\/h3\u003e \u003cp\u003eThe Victron 12\/24V 25A Buck-Boost DC-DC Converter is the perfect solution for charging a 12V or 24V service battery in vehicles equipped with a smart alternator, including those with Euro 5 and Euro 6 engines featuring regenerative braking. Designed to handle both high and low voltage scenarios, this converter ensures your auxiliary battery receives a consistent charge, eliminating potential voltage issues common in smart alternators.\u003c\/p\u003e \u003ch3\u003eKey Features\u003c\/h3\u003e \u003ch4\u003eVersatile Compatibility\u003c\/h4\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eSupports Multiple Systems:\u003c\/strong\u003e Suitable for 12V, 24V, and 12\/24V systems, the converter can be programmed to charge a 12V or 24V auxiliary battery from a 12V or 24V alternator and starter battery.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003ePre-set Charge Voltage:\u003c\/strong\u003e Ensures stable charging by managing high voltages (e.g., Mercedes: 15.4V) and low voltages.\u003c\/li\u003e \u003c\/ul\u003e \u003ch4\u003eIntelligent Design\u003c\/h4\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eEngine Running Detection:\u003c\/strong\u003e Built-in system prevents deep discharge of the vehicle's starting battery by detecting when the engine is running. Alternatively, the converter can be activated via programmable inputs (D+, CAN bus, or (+)15 connection). \u003cstrong\u003eNote the 25A Model does \u003cu\u003enot\u003c\/u\u003e have CANBus.\u003c\/strong\u003e\n\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eFully Programmable:\u003c\/strong\u003e Easily program the converter using a simple and user-friendly PC application. (USB type A male to USB type B male cable required.)\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003ePerformance and Safety\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eCharge Current and Input Current Limiter:\u003c\/strong\u003e The output current is regulated by the maximum charge current setting, input current setting, and the converter's maximum operating temperature limit.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eStatus Indication LEDs:\u003c\/strong\u003e Clear visual indicators for input and output status to ensure optimal operation and troubleshooting.\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eApplications\u003c\/h3\u003e \u003cp\u003eIdeal for various applications including:\u003c\/p\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eTrucks, Buses and RVs:\u003c\/strong\u003e Maintain your service batteries efficiently while traveling.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMarine:\u003c\/strong\u003e Reliable power management for boats with smart alternators.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eOff-Grid and Industrial:\u003c\/strong\u003e Perfect for remote power systems and industrial equipment.\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eUpgrade Your Power System\u003c\/h3\u003e \u003cp\u003eEnsure your vehicle's auxiliary battery is always charged and ready with the Victron 12\/24V 25A Buck-Boost DC-DC Converter. Optimize your power management and prevent battery issues with this versatile and intelligent converter.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eOrder yours today and experience seamless battery charging in your vehicle!\u003c\/strong\u003e\u003c\/p\u003e \n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e25A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eInput voltage range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e10-30V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage threshold\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e10V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e10-30V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum charge current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e12V: 25A 24V: 15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eConverter off, LEDs off (power save mode)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e7 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eProgrammable input: 'On' threshold voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026gt; 2V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eProgrammable input: maximum voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e30V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eProgrammable output: voltage if activated\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eV input = Vin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eProgrammable output: maximum current (per pin)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eI input = 1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-25 to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eMax current: up to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e0.6kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e165 x 120 x 30mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364310053147,"sku":"Vic-ORI303025000","price":769.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/Vic-ORI303025000-01.jpg?v=1781658368"},{"product_id":"victron-50a-buck-boost-dc-dc-converter","title":"Victron Energy - 12\/24V- 50A - Buck-Boost - DC-DC Converter","description":"\u003ch2\u003eVictron 12\/24V 50A Buck-Boost DC-DC Converter\u003c\/h2\u003e \u003ch3\u003eEfficient Charging for Service Batteries in Vehicles with Smart Alternators\u003c\/h3\u003e \u003cp\u003eThe Victron 12\/24V 50A Buck-Boost DC-DC Converter is designed to provide efficient charging for a 12V or 24V service battery in vehicles equipped with smart alternators, including those with Euro 5 and Euro 6 engines featuring regenerative braking. This advanced converter ensures your auxiliary battery receives a consistent charge by managing both high and low voltage scenarios, eliminating potential issues common in smart alternators.\u003c\/p\u003e \u003ch3\u003eKey Features\u003c\/h3\u003e \u003ch4\u003eVersatile Compatibility\u003c\/h4\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eSupports Multiple Systems:\u003c\/strong\u003e The converter is suitable for 12V, 24V, and 12\/24V systems, allowing you to charge a 12V or 24V auxiliary battery from a 12V or 24V alternator and starter battery.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003ePre-set Charge Voltage:\u003c\/strong\u003e Ensures stable charging by regulating high voltages (e.g., Mercedes: 15.4V) and low voltages.\u003c\/li\u003e \u003c\/ul\u003e \u003ch4\u003eIntelligent Design\u003c\/h4\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eEngine Running Detection:\u003c\/strong\u003e This built-in system prevents deep discharge of the vehicle's starting battery by detecting when the engine is running. Alternatively, the converter can be activated via programmable inputs (D+, CAN bus, or (+)15 connection).\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eFully Programmable:\u003c\/strong\u003e Easily program the converter using a simple and user-friendly PC application (USB type A male to USB type B male cable required).\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003ePerformance and Safety\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eCharge Current and Input Current Limiter:\u003c\/strong\u003e The output current is regulated by the maximum charge current setting, input current setting, and the converter's maximum operating temperature limit.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eStatus Indication LEDs:\u003c\/strong\u003e Clear visual indicators for input and output status ensure optimal operation and troubleshooting.\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eApplications\u003c\/h3\u003e \u003cp\u003eIdeal for various applications including:\u003c\/p\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eTrucks, Buses, and RVs:\u003c\/strong\u003e Maintain your service batteries efficiently while traveling.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMarine:\u003c\/strong\u003e Reliable power management for boats with smart alternators.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eOff-Grid and Industrial:\u003c\/strong\u003e Perfect for remote power systems and industrial equipment.\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eUpgrade Your Power System\u003c\/h3\u003e \u003cp\u003eEnsure your vehicle's auxiliary battery is always charged and ready with the Victron 12\/24V 50A Buck-Boost DC-DC Converter. Optimize your power management and prevent battery issues with this versatile and intelligent converter.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eOrder yours today and experience seamless battery charging in your vehicle!\u003c\/strong\u003e\u003c\/p\u003e \n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e50A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eInput voltage range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e10-30V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage threshold\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e10V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e10-30V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum charge current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e12V: 50A 24V: 25A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eConverter off, LEDs off (power save mode)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e7 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003e'On' threshold voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026gt; 2V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum input voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e30V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage if activated\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eV input = Vin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum current (per pin)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eI input = 1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-25 to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eMax current: up to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e1.4kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e213 x 120 x 30mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364323488027,"sku":"Vic-ORI303050000","price":919.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/Vic-ORI303050000-01.jpg?v=1781658368"},{"product_id":"victron-orion-12v-to-24v-10a-non-isolated-dc-dc-converter-ip20","title":"Victron Energy - 12V to 24V - Orion 12\/24-10A - Non-Isolated IP20 - DC-DC Converter","description":"\u003ch2\u003eVictron 12V to 24V Orion 12\/24-10A Non-Isolated IP20 DC-DC Converter\u003c\/h2\u003e\n\u003ch3\u003eProfessional-Grade DC-DC Conversion for Demanding Mobile and Off-Grid Systems\u003c\/h3\u003e\n\u003cp\u003eEngineered for reliability in the toughest environments, the Victron Orion 12\/24-10A DC-DC converter delivers clean, stable power conversion with industry-leading efficiency. This non-isolated converter ensures your sensitive electronics and battery banks receive precisely regulated power, reducing the risk of voltage drop and equipment malfunction common with lower-grade alternatives.\u003c\/p\u003e\n\u003cp\u003eUnlike generic converters that struggle with fluctuating input voltages, the Orion maintains consistent output even under variable loads, making it the preferred choice for professional installers and system integrators across Australia. Its robust design and advanced protection features safeguard your investment, providing peace of mind for critical applications where power stability is non-negotiable.\u003c\/p\u003e\n\u003ch3\u003eAdvanced Power Conversion Technology\u003c\/h3\u003e\n\u003cp\u003eAt the core of the Orion is a high-frequency switchmode design that achieves up to 95% conversion efficiency, minimising wasted energy and heat generation. This not only reduces thermal stress on the unit but also preserves precious battery capacity in off-grid setups. The result is cooler operation, longer service life, and more usable power for your loads.\u003c\/p\u003e\n\u003cp\u003eWith an input voltage range of 9-18V, the converter handles the wide voltage swings typical of alternator charging and battery discharge cycles without interruption. An intelligent under-voltage shutdown protects your source battery from deep discharge, automatically restarting when voltage recovers to a safe level.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Efficiency up to 95%\u003c\/strong\u003e – reduces energy loss and heat buildup for reliable long-term operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Input Voltage Range (9-18V)\u003c\/strong\u003e – accommodates real-world voltage fluctuations without performance drop\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous Output Current of 10A\u003c\/strong\u003e – powers demanding loads with headroom for surges\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact IP20 Aluminium Enclosure\u003c\/strong\u003e – durable and lightweight, with integrated mounting points for secure installation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Against Under-Voltage, Over-Temperature, and Short Circuit\u003c\/strong\u003e – safeguards both the converter and connected equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eParallel Connection Support\u003c\/strong\u003e – scale output current by linking multiple units for larger systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable Output Voltage\u003c\/strong\u003e – fine-tune voltage to match specific battery chemistries or load requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eBuilt for Australian Conditions\u003c\/h3\u003e\n\u003cp\u003eFrom the corrugations of the Outback to the corrosive salt air of coastal waters, the Orion is built to endure. Its anodised aluminium chassis resists corrosion while acting as an effective heat sink. The IP20 rating suits protected installations inside vehicles, vessels, and equipment enclosures, where it is shielded from direct weather but still benefits from passive or active cooling.\u003c\/p\u003e\n\u003cp\u003eAll DC connections are engineered for low resistance and high current handling, using Faston tabs 6.3 mm terminals that accept appropriately sized lugs for minimal voltage drop. This attention to detail ensures maximum power transfer and reduces the risk of hot connections that plague inferior products.\u003c\/p\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe Orion 12\/24-10A converter excels wherever reliable DC voltage conversion is required:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine and Boating\u003c\/strong\u003e – power 24V electronics from a 12V house bank\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecreational Vehicles and Caravans\u003c\/strong\u003e – run 24V appliances from a 12V system, or maintain auxiliary batteries while driving\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-Grid Solar Systems\u003c\/strong\u003e – interface between different battery voltages or power 24V equipment from a 12V battery bank\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial and Mobile Plant\u003c\/strong\u003e – provide stable voltage for control systems, communication gear, and monitoring equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmergency Services and Fleet Vehicles\u003c\/strong\u003e – ensure critical 12V or 24V loads remain operational regardless of vehicle voltage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Professionals Choose Victron Orion\u003c\/h3\u003e\n\u003cp\u003eGeneric DC-DC converters often fail prematurely due to inadequate cooling, poor voltage regulation, or lack of protection features. The Orion addresses these risks with a proven design backed by Victron's decades of power electronics expertise. Its conservative component ratings and comprehensive testing mean it performs reliably year after year, reducing downtime and replacement costs.\u003c\/p\u003e\n\u003cp\u003eInstallation is straightforward, with clear terminal markings and included accessories where applicable. The compact footprint allows mounting in tight spaces, while the lightweight construction minimises added weight to vehicles and vessels.\u003c\/p\u003e\n\u003ch3\u003ePower Your System with Confidence\u003c\/h3\u003e\n\u003cp\u003eEquip your setup with the Victron Orion 12\/24-10A DC-DC converter and experience the difference professional-grade power conversion makes. Whether you're upgrading an existing system or building from scratch, this converter delivers the performance and durability needed for Australia's harshest environments. Add it to your power system today and ensure your critical loads always receive clean, stable voltage.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eOrion 12\/24-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eInput voltage range (V)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e9-18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage shutdown (V)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage restart (V)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage adjustable with potentiometer\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage (V)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eAdjustable 20-30V F set 26.4V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEfficiency (%)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eSuitable to buffer-charge a battery\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCan be connected in parallel\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eContinuous output current (A)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMax. Output current (A)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eFan assisted cooling (temp. controlled)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eGalvanic isolation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOff load current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 15mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eRemote on-off\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOperating temperature range (derate 3% per °C above 40°C)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-20 to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDC connection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eFaston tabs 6.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight kg (lbs)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e0.4 (0.9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions hxwxd in mm (hxwxd in inches)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e45x90x125 (1.8x3.5x4.9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards: Safety Emission Immunity Automotive Directive\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 60950 EN 61000-6-3, EN 55014-1 EN 61000-6-2, EN 61000-6-1, EN 55014-2 ECE R10-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364384436507,"sku":"VIC-ORI122410020","price":85.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/VIC-ORI122410020-01.jpg?v=1781658178"},{"product_id":"victron-orion-12v-to-24v-20a-non-isolated-dc-dc-converter-ip20","title":"Victron Energy - 12V to 24V - Orion 12\/24-20A - Non-Isolated IP20 - DC-DC Converter","description":"\u003ch2\u003eVictron 12V to 24V Orion 12\/24-20A Non-Isolated IP20 DC-DC Converter\u003c\/h2\u003e\n\u003ch3\u003eProfessional-Grade DC-DC Conversion for Demanding Mobile and Off-Grid Systems\u003c\/h3\u003e\n\u003cp\u003eEngineered for reliability in the toughest environments, the Victron Orion 12\/24-20A DC-DC converter delivers clean, stable power conversion with industry-leading efficiency. This non-isolated converter ensures your sensitive electronics and battery banks receive precisely regulated power, reducing the risk of voltage drop and equipment malfunction common with lower-grade alternatives.\u003c\/p\u003e\n\u003cp\u003eUnlike generic converters that struggle with fluctuating input voltages, the Orion maintains consistent output even under variable loads, making it the preferred choice for professional installers and system integrators across Australia. Its robust design and advanced protection features safeguard your investment, providing peace of mind for critical applications where power stability is non-negotiable.\u003c\/p\u003e\n\u003ch3\u003eAdvanced Power Conversion Technology\u003c\/h3\u003e\n\u003cp\u003eAt the core of the Orion is a high-frequency switchmode design that achieves up to 93% conversion efficiency, minimising wasted energy and heat generation. This not only reduces thermal stress on the unit but also preserves precious battery capacity in off-grid setups. The result is cooler operation, longer service life, and more usable power for your loads.\u003c\/p\u003e\n\u003cp\u003eWith an input voltage range of 9-18V, the converter handles the wide voltage swings typical of alternator charging and battery discharge cycles without interruption. An intelligent under-voltage shutdown protects your source battery from deep discharge, automatically restarting when voltage recovers to a safe level.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Efficiency up to 93%\u003c\/strong\u003e – reduces energy loss and heat buildup for reliable long-term operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Input Voltage Range (9-18V)\u003c\/strong\u003e – accommodates real-world voltage fluctuations without performance drop\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous Output Current of 20A\u003c\/strong\u003e – powers demanding loads with headroom for surges\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact IP20 Aluminium Enclosure\u003c\/strong\u003e – durable and lightweight, with integrated mounting points for secure installation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Against Under-Voltage, Over-Temperature, and Short Circuit\u003c\/strong\u003e – safeguards both the converter and connected equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote On-Off Capability\u003c\/strong\u003e – enables system-level control without high-current switching\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eParallel Connection Support\u003c\/strong\u003e – scale output current by linking multiple units for larger systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable Output Voltage\u003c\/strong\u003e – fine-tune voltage to match specific battery chemistries or load requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eBuilt for Australian Conditions\u003c\/h3\u003e\n\u003cp\u003eFrom the corrugations of the Outback to the corrosive salt air of coastal waters, the Orion is built to endure. Its anodised aluminium chassis resists corrosion while acting as an effective heat sink. The IP20 rating suits protected installations inside vehicles, vessels, and equipment enclosures, where it is shielded from direct weather but still benefits from passive or active cooling.\u003c\/p\u003e\n\u003cp\u003eAll DC connections are engineered for low resistance and high current handling, using M6 bolt terminals that accept appropriately sized lugs for minimal voltage drop. This attention to detail ensures maximum power transfer and reduces the risk of hot connections that plague inferior products.\u003c\/p\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe Orion 12\/24-20A converter excels wherever reliable DC voltage conversion is required:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine and Boating\u003c\/strong\u003e – power 24V electronics from a 12V house bank\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecreational Vehicles and Caravans\u003c\/strong\u003e – run 24V appliances from a 12V system, or maintain auxiliary batteries while driving\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-Grid Solar Systems\u003c\/strong\u003e – interface between different battery voltages or power 24V equipment from a 12V battery bank\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial and Mobile Plant\u003c\/strong\u003e – provide stable voltage for control systems, communication gear, and monitoring equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmergency Services and Fleet Vehicles\u003c\/strong\u003e – ensure critical 12V or 24V loads remain operational regardless of vehicle voltage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Professionals Choose Victron Orion\u003c\/h3\u003e\n\u003cp\u003eGeneric DC-DC converters often fail prematurely due to inadequate cooling, poor voltage regulation, or lack of protection features. The Orion addresses these risks with a proven design backed by Victron's decades of power electronics expertise. Its conservative component ratings and comprehensive testing mean it performs reliably year after year, reducing downtime and replacement costs.\u003c\/p\u003e\n\u003cp\u003eInstallation is straightforward, with clear terminal markings and included accessories where applicable. The compact footprint allows mounting in tight spaces, while the lightweight construction minimises added weight to vehicles and vessels.\u003c\/p\u003e\n\u003ch3\u003ePower Your System with Confidence\u003c\/h3\u003e\n\u003cp\u003eEquip your setup with the Victron Orion 12\/24-20A DC-DC converter and experience the difference professional-grade power conversion makes. Whether you're upgrading an existing system or building from scratch, this converter delivers the performance and durability needed for Australia's harshest environments. Add it to your power system today and ensure your critical loads always receive clean, stable voltage.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eOrion 12\/24-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eInput voltage range (V)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e9-18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage shutdown (V)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage restart (V)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage adjustable with potentiometer\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage (V)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eAdjustable 20-30V F set 26.4V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEfficiency (%)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e93\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eSuitable to buffer-charge a battery\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCan be connected in parallel\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eContinuous output current (A)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMax. Output current (A)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eFan assisted cooling (temp. controlled)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eGalvanic isolation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOff load current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eRemote on-off\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOperating temperature range (derate 3% per °C above 40°C)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-20 to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDC connection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eM6 bolts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight kg (lbs)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e0.85 (1.9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions hxwxd in mm (hxwxd in inches)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e65x88x195 (2.6x3.5x7.7)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards: Safety Emission Immunity Automotive Directive\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 60950 EN 61000-6-3, EN 55014-1 EN 61000-6-2, EN 61000-6-1, EN 55014-2 ECE R10-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364384829723,"sku":"VIC-ORI122420020","price":164.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/VIC-ORI122420020-01.jpg?v=1781658168"},{"product_id":"victron-orion-12v-to-24v-8a-non-isolated-dc-dc-converter-ip20","title":"Victron Energy - 12V to 24V - Orion 12\/24-8A - Non-Isolated IP20 - DC-DC Converter","description":"\u003ch2\u003eVictron 12V to 24V Orion 12\/24-8A Non-Isolated IP20 DC-DC Converter\u003c\/h2\u003e\n\u003ch3\u003eProfessional-Grade DC-DC Conversion for Demanding Mobile and Off-Grid Systems\u003c\/h3\u003e\n\u003cp\u003eEngineered for reliability in the toughest environments, the Victron Orion 12\/24-8A DC-DC converter delivers clean, stable power conversion with industry-leading efficiency. This non-isolated converter ensures your sensitive electronics and battery banks receive precisely regulated power, reducing the risk of voltage drop and equipment malfunction common with lower-grade alternatives.\u003c\/p\u003e\n\u003cp\u003eUnlike generic converters that struggle with fluctuating input voltages, the Orion maintains consistent output even under variable loads, making it the preferred choice for professional installers and system integrators across Australia. Its robust design and advanced protection features safeguard your investment, providing peace of mind for critical applications where power stability is non-negotiable.\u003c\/p\u003e\n\u003ch3\u003eAdvanced Power Conversion Technology\u003c\/h3\u003e\n\u003cp\u003eAt the core of the Orion is a high-frequency switchmode design that achieves up to 95% conversion efficiency, minimising wasted energy and heat generation. This not only reduces thermal stress on the unit but also preserves precious battery capacity in off-grid setups. The result is cooler operation, longer service life, and more usable power for your loads.\u003c\/p\u003e\n\u003cp\u003eWith an input voltage range of 9-18V, the converter handles the wide voltage swings typical of alternator charging and battery discharge cycles without interruption. An intelligent under-voltage shutdown protects your source battery from deep discharge, automatically restarting when voltage recovers to a safe level.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Efficiency up to 95%\u003c\/strong\u003e – reduces energy loss and heat buildup for reliable long-term operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Input Voltage Range (9-18V)\u003c\/strong\u003e – accommodates real-world voltage fluctuations without performance drop\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous Output Current of 8A\u003c\/strong\u003e – powers demanding loads with headroom for surges\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact IP20 Aluminium Enclosure\u003c\/strong\u003e – durable and lightweight, with integrated mounting points for secure installation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Against Under-Voltage, Over-Temperature, and Short Circuit\u003c\/strong\u003e – safeguards both the converter and connected equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eBuilt for Australian Conditions\u003c\/h3\u003e\n\u003cp\u003eFrom the corrugations of the Outback to the corrosive salt air of coastal waters, the Orion is built to endure. Its anodised aluminium chassis resists corrosion while acting as an effective heat sink. The IP20 rating suits protected installations inside vehicles, vessels, and equipment enclosures, where it is shielded from direct weather but still benefits from passive or active cooling.\u003c\/p\u003e\n\u003cp\u003eAll DC connections are engineered for low resistance and high current handling, using Faston tabs 6.3 mm terminals that accept appropriately sized lugs for minimal voltage drop. This attention to detail ensures maximum power transfer and reduces the risk of hot connections that plague inferior products.\u003c\/p\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe Orion 12\/24-8A converter excels wherever reliable DC voltage conversion is required:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine and Boating\u003c\/strong\u003e – power 24V electronics from a 12V house bank\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecreational Vehicles and Caravans\u003c\/strong\u003e – run 24V appliances from a 12V system, or maintain auxiliary batteries while driving\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-Grid Solar Systems\u003c\/strong\u003e – interface between different battery voltages or power 24V equipment from a 12V battery bank\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial and Mobile Plant\u003c\/strong\u003e – provide stable voltage for control systems, communication gear, and monitoring equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmergency Services and Fleet Vehicles\u003c\/strong\u003e – ensure critical 12V or 24V loads remain operational regardless of vehicle voltage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Professionals Choose Victron Orion\u003c\/h3\u003e\n\u003cp\u003eGeneric DC-DC converters often fail prematurely due to inadequate cooling, poor voltage regulation, or lack of protection features. The Orion addresses these risks with a proven design backed by Victron's decades of power electronics expertise. Its conservative component ratings and comprehensive testing mean it performs reliably year after year, reducing downtime and replacement costs.\u003c\/p\u003e\n\u003cp\u003eInstallation is straightforward, with clear terminal markings and included accessories where applicable. The compact footprint allows mounting in tight spaces, while the lightweight construction minimises added weight to vehicles and vessels.\u003c\/p\u003e\n\u003ch3\u003ePower Your System with Confidence\u003c\/h3\u003e\n\u003cp\u003eEquip your setup with the Victron Orion 12\/24-8A DC-DC converter and experience the difference professional-grade power conversion makes. Whether you're upgrading an existing system or building from scratch, this converter delivers the performance and durability needed for Australia's harshest environments. Add it to your power system today and ensure your critical loads always receive clean, stable voltage.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eOrion 12\/24-8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eInput voltage range (V)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e9-18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage shutdown (V)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage restart (V)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage adjustable with potentiometer\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage (V)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEfficiency (%)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eSuitable to buffer-charge a battery\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCan be connected in parallel\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eContinuous output current (A)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMax. Output current (A)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eFan assisted cooling (temp. controlled)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eGalvanic isolation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOff load current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 10mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eRemote on-off\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOperating temperature range (derate 3% per °C above 40°C)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-20 to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDC connection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eFaston tabs 6.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight kg (lbs)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e0.4 (0.9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions hxwxd in mm (hxwxd in inches)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e45x90x115 (1.8x3.5x4.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards: Safety Emission Immunity Automotive Directive\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 60950 EN 61000-6-3, EN 55014-1 EN 61000-6-2, EN 61000-6-1, EN 55014-2 ECE R10-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364385157403,"sku":"VIC-ORI122408020","price":82.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/VIC-ORI122408020-01.jpg?v=1781658177"},{"product_id":"victron-orion-24v-to-12v-25a-non-isolated-dc-dc-converter-ip20","title":"Victron Energy - 24V to 12V - 25A - Orion 24\/12-25A Non-Isolated IP20 - DC-DC Converter","description":"\u003ch2\u003eVictron 24V to 12V Orion 24\/12-25A Non-Isolated IP20 DC-DC Converter\u003c\/h2\u003e\n\u003ch3\u003eProfessional-Grade DC-DC Conversion for Demanding Mobile and Off-Grid Systems\u003c\/h3\u003e\n\u003cp\u003eEngineered for reliability in the toughest environments, the Victron Orion 24\/12-25A DC-DC converter delivers clean, stable power conversion with industry-leading efficiency. Whether you're stepping voltage down from 24V to 12V, this non-isolated converter ensures your sensitive electronics and battery banks receive precisely regulated power, reducing the risk of voltage drop and equipment malfunction common with lower-grade alternatives.\u003c\/p\u003e\n\u003cp\u003eUnlike generic converters that struggle with fluctuating input voltages, the Orion maintains consistent output even under variable loads, making it the preferred choice for professional installers and system integrators across Australia. Its robust design and advanced protection features safeguard your investment, providing peace of mind for critical applications where power stability is non-negotiable.\u003c\/p\u003e\n\u003ch3\u003eAdvanced Power Conversion Technology\u003c\/h3\u003e\n\u003cp\u003eAt the core of the Orion is a high-frequency switchmode design that achieves up to 96% conversion efficiency, minimising wasted energy and heat generation. This not only reduces thermal stress on the unit but also preserves precious battery capacity in off-grid setups. The result is cooler operation, longer service life, and more usable power for your loads.\u003c\/p\u003e\n\u003cp\u003eWith an input voltage range of 18-35V, the converter handles the wide voltage swings typical of alternator charging and battery discharge cycles without interruption. An intelligent under-voltage shutdown protects your source battery from deep discharge, automatically restarting when voltage recovers to a safe level.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Efficiency up to 96%\u003c\/strong\u003e – reduces energy loss and heat buildup for reliable long-term operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Input Voltage Range (18-35V)\u003c\/strong\u003e – accommodates real-world voltage fluctuations without performance drop\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous Output Current of 25A\u003c\/strong\u003e – powers demanding loads with headroom for surges\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact IP20 Aluminium Enclosure\u003c\/strong\u003e – durable and lightweight, with integrated mounting points for secure installation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Against Under-Voltage, Over-Temperature, and Short Circuit\u003c\/strong\u003e – safeguards both the converter and connected equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote On-Off Capability\u003c\/strong\u003e – enables system-level control without high-current switching\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eParallel Connection Support\u003c\/strong\u003e – scale output current by linking multiple units for larger systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable Output Voltage\u003c\/strong\u003e – fine-tune voltage to match specific battery chemistries or load requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eBuilt for Australian Conditions\u003c\/h3\u003e\n\u003cp\u003eFrom the corrugations of the Outback to the corrosive salt air of coastal waters, the Orion is built to endure. Its anodised aluminium chassis resists corrosion while acting as an effective heat sink. The IP20 rating suits protected installations inside vehicles, vessels, and equipment enclosures, where it is shielded from direct weather but still benefits from passive or active cooling.\u003c\/p\u003e\n\u003cp\u003eAll DC connections are engineered for low resistance and high current handling, using Faston tabs 6.3 mm terminals that accept appropriately sized lugs for minimal voltage drop. This attention to detail ensures maximum power transfer and reduces the risk of hot connections that plague inferior products.\u003c\/p\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe Orion 24\/12-25A converter excels wherever reliable DC voltage conversion is required:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine and Boating\u003c\/strong\u003e – power 12V electronics from a 24V house bank, or charge a 12V starter battery from a 24V alternator\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecreational Vehicles and Caravans\u003c\/strong\u003e – run 12V appliances from a 24V system, or maintain auxiliary batteries while driving\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-Grid Solar Systems\u003c\/strong\u003e – interface between different battery voltages or power 12V equipment from a 24V battery bank\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial and Mobile Plant\u003c\/strong\u003e – provide stable voltage for control systems, communication gear, and monitoring equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmergency Services and Fleet Vehicles\u003c\/strong\u003e – ensure critical 12V loads remain operational regardless of vehicle voltage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Professionals Choose Victron Orion\u003c\/h3\u003e\n\u003cp\u003eGeneric DC-DC converters often fail prematurely due to inadequate cooling, poor voltage regulation, or lack of protection features. The Orion addresses these risks with a proven design backed by Victron's decades of power electronics expertise. Its conservative component ratings and comprehensive testing mean it performs reliably year after year, reducing downtime and replacement costs.\u003c\/p\u003e\n\u003cp\u003eInstallation is straightforward, with clear terminal markings and included accessories where applicable. The compact footprint allows mounting in tight spaces, while the lightweight construction minimises added weight to vehicles and vessels.\u003c\/p\u003e\n\u003ch3\u003ePower Your System with Confidence\u003c\/h3\u003e\n\u003cp\u003eEquip your setup with the Victron Orion 24\/12-25A DC-DC converter and experience the difference professional-grade power conversion makes. Whether you're upgrading an existing system or building from scratch, this converter delivers the performance and durability needed for Australia's harshest environments. Add it to your power system today and ensure your critical loads always receive clean, stable voltage.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eOrion 24\/12-25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eInput voltage range (V)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e18-35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage shutdown (V)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage restart (V)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage adjustable with potentiometer\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage (V)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eAdjustable 10-15V, factory set 13.2V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEfficiency (%)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e96\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eSuitable to buffer-charge a battery\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCan be connected in parallel\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eContinuous output current (A)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMax. Output current (A)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eFan assisted cooling (temp. controlled)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eGalvanic isolation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOff load current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 15mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eRemote on-off\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOperating temperature range (derate 3% per °C above 40°C)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-20 to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDC connection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eFaston tabs 6.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight kg (lbs)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e0.7 (1.55)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions hxwxd in mm (hxwxd in inches)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e65x88x160 (2.6x3.5x6.3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards: Safety Emission Immunity Automotive Directive\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 60950 EN 61000-6-3, EN 55014-1 EN 61000-6-2, EN 61000-6-1, EN 55014-2 ECE R10-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364385354011,"sku":"VIC-ORI241225020","price":104.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/VIC-ORI241225020-01.jpg?v=1781658354"},{"product_id":"victron-orion-ip67-12v-to-24v-50a-non-isolated-waterproof-dc-dc-converter","title":"Victron Energy - 12V to 24V - Orion 12\/24-50A - Non-Isolated IP67 - DC-DC Converter","description":"\u003ch2\u003eVictron 12V to 24V Orion 12\/24-50A (1200W) Non-Isolated IP67 DC-DC Converter\u003c\/h2\u003e \u003ch3\u003eReliable Power Conversion for Demanding Environments\u003c\/h3\u003e \u003cp\u003eThe Victron 12V to 24V Orion 12\/24-50A Non-Isolated IP67 DC-DC Converter is designed for reliability and efficiency, ensuring your equipment gets the power it needs in even the harshest conditions. This converter is ideal for applications such as caravans, RVs, marine, off-grid systems, industrial machinery, and tiny homes.\u003c\/p\u003e \u003ch3\u003eKey Features\u003c\/h3\u003e \u003ch4\u003eCompletely Encapsulated for Ultimate Protection\u003c\/h4\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eWaterproof, Shockproof, and Ignition Protected\u003c\/strong\u003e: The Orion IP67 DC-DC Converter is completely encapsulated, making it impervious to water, oil, and dirt. Its robust cast aluminum casing and resin-moulded electronics guarantee long-lasting durability in the toughest environments.\u003c\/li\u003e \u003c\/ul\u003e \u003ch4\u003eWide Input Voltage Range\u003c\/h4\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eStable Output Voltage\u003c\/strong\u003e: The wide input voltage range ensures a stable output, even during voltage surges or sags caused by other equipment connected to the same battery. This stability is crucial for maintaining the performance and longevity of your devices.\u003c\/li\u003e \u003c\/ul\u003e \u003ch4\u003eOverheating Protection\u003c\/h4\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eHeat-Resistant Design\u003c\/strong\u003e: The converter is designed to operate efficiently in hot environments, such as machine rooms. Its overheating protection feature ensures reliable performance without the risk of damage, even under heavy load conditions.\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eBenefits\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eDurability\u003c\/strong\u003e: With its IP67 rating, the converter is built to withstand extreme environmental conditions, providing peace of mind and reducing maintenance needs.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eVersatility\u003c\/strong\u003e: Ideal for a range of applications including caravans, RVs, marine systems, off-grid setups, industrial machinery, and tiny homes, this converter adapts to your specific power needs.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eReliability\u003c\/strong\u003e: The combination of a wide input voltage range and overheating protection ensures your equipment receives consistent, reliable power, minimizing downtime and enhancing operational efficiency.\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eApplications\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eCaravans and RVs\u003c\/strong\u003e: Ensure your recreational vehicles have reliable power for all onboard systems and devices.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMarine\u003c\/strong\u003e: Power your boat's electronics and systems with confidence, even in harsh marine environments.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eOff-Grid Systems\u003c\/strong\u003e: Maintain consistent power supply for off-grid homes or remote installations.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eIndustrial Machinery\u003c\/strong\u003e: Provide stable power for industrial equipment in demanding conditions.\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eUpgrade Your Power System Now!\u003c\/h3\u003e \u003cp\u003eInvest in the Victron 12V to 24V Orion 12\/24-50A Non-Isolated IP67 DC-DC Converter today to ensure your equipment operates smoothly and efficiently in any environment. Enhance your power reliability and protect your investment with this robust and versatile converter.\u003c\/p\u003e \n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOrion IP67\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e12\/24-50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eInput voltage range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e10-15VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage shutdown\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e8V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage restart\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e9V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNo load current at 24V\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e45mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDC output voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e24V +\/- 3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum continuous output current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e50A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEfficiency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eRipple \u0026amp; Noise\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e150mVpp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-40 to +70°C (full rated output up to 40°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOverload protection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eHiccup mode, recovers automatically after fault condition is removed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eShort circuit proof\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eProtection against reverse polarity connection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eWith external fuse or circuit breaker (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaterial \u0026amp; Colour\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eAluminium (blue RAL 5012)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eProtection category\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDC connection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eBolts M6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCable cross section, input\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003en.a.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCable cross section, output\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003en.a.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight (kg)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e2.15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions (h x w x d in mm)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e265 x 127 x 63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eSafety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 60950\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEmission\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-3, EN 55014-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eImmunity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 55014-2, EN 61000-6-1, EN 61000-6-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eVibration\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eIEC 68-2-6: 10-150 Hz \/ 1.0 G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364386402587,"sku":"VIC-ORI122421226","price":369.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/VIC-ORI122421226-01.jpg?v=1781658168"},{"product_id":"victron-orion-ip67-24v-to-12v-100a-non-isolated-waterproof-dc-dc-converter","title":"Victron Energy - 24V to 12V - 100A - Orion 24\/12-100A Non-Isolated IP67 - DC-DC Converter","description":"\u003ch2\u003eHigh-Performance 24V to 12V Voltage Reduction for Extreme Environments\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eVictron 24V to 12V Orion 24\/12-100A Non-Isolated IP67 DC-DC Converter\u003c\/strong\u003e provides a highly resilient solution for stepping down high-voltage battery banks to run standard 12V equipment. Designed specifically for demanding marine, automotive, and industrial applications, this robust \u003cstrong\u003e24V to 12V converter 100A\u003c\/strong\u003e ensures your sensitive electronics receive a stable, clean power supply. Whether you need a heavy-duty \u003cstrong\u003e12V voltage regulator for car\u003c\/strong\u003e and commercial vehicle applications or a reliable step-down unit for an off-grid 24V solar system, this converter delivers exceptional continuous power up to 1200W.\u003c\/p\u003e\n\u003ch3\u003eFully Encapsulated for Unmatched Reliability\u003c\/h3\u003e\n\u003cp\u003eStandard DC-DC converters often fail in harsh environments due to moisture ingress, dust, and vibration. The \u003cstrong\u003eOrion IP67 24\/12-100\u003c\/strong\u003e eliminates these risks entirely. It is completely encapsulated in a durable cast aluminium casing, with all internal electronics precision-moulded in resin. This makes the unit fully waterproof, shockproof, and ignition-protected. It is uniquely engineered to withstand prolonged exposure to water, oil, dirt, and severe mechanical vibration, ensuring uninterrupted performance in engine rooms, bilges, or external vehicle mounts.\u003c\/p\u003e\n\u003ch3\u003eAdvanced Thermal Management and 96% Efficiency\u003c\/h3\u003e\n\u003cp\u003eEfficiency is critical in battery-based systems. By achieving an outstanding 96% conversion efficiency, the Victron IP67 converter dramatically reduces energy waste and heat generation. Instead of relying on mechanical cooling fans that are prone to failure, the unit utilizes passive cooling through its integrated aluminium heatsink fins. This fanless design not only increases the lifespan of the equipment but also allows it to operate safely in ambient temperatures ranging from freezing cold up to extreme heat, maintaining optimal output when you need it most.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP67 Waterproof and Dustproof:\u003c\/strong\u003e Fully encapsulated resin design protects against all environmental hazards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Efficiency 96% Conversion:\u003c\/strong\u003e Minimizes power loss and reduces battery drain.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Input Voltage Range:\u003c\/strong\u003e Accepts 18V to 35V DC input, providing stable 12V output even during system voltage fluctuations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeavy-Duty Connections:\u003c\/strong\u003e Equipped with M6 bolt terminals for secure, high-current wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive Protection:\u003c\/strong\u003e Features short circuit proofing and overload protection with an automatic hiccup-mode recovery.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eVersatile Applications and System Protection\u003c\/h3\u003e\n\u003cp\u003eThis unit goes beyond standard voltage conversion. It actively protects your 12V circuits by smoothing out harmful voltage drops and surges originating from the 24V supply line, acting as an industrial-grade voltage regulator. It is an essential component for marine vessels with 24V alternators needing to run 12V navigation equipment, or heavy-duty 4WDs and trucks running dual-voltage setups. While commonly searched as a \u003cstrong\u003e100A dc to dc charger\u003c\/strong\u003e due to its high current rating, its primary function is delivering a massive 100 amps of continuous, precisely regulated 12V power to heavy loads without missing a beat.\u003c\/p\u003e\n\u003ch3\u003eSimplified Installation and Integration\u003c\/h3\u003e\n\u003cp\u003eWiring high-capacity DC systems requires secure, low-resistance connections to prevent voltage drop and localized heating. The Orion IP67 DC-DC converter addresses this by featuring robust M6 bolt terminals for both input and output connections. This allows installers to utilize heavy-duty copper cable and properly crimped lugs to safely manage the 100A continuous output. Furthermore, the compact footprint and flexible mounting orientations make it straightforward to install in confined spaces, from crowded boat consoles to the chassis of industrial machinery. Please note that while the unit is highly protected against overloads, an external fuse or circuit breaker is required to protect against reverse polarity connections.\u003c\/p\u003e\n\u003ch3\u003eUpgrade Your Power System\u003c\/h3\u003e\n\u003cp\u003eSecure your critical electronics with a power regulator built to outlast the conditions. Equip your marine vessel, commercial vehicle, or remote off-grid setup with the Victron 24V to 12V Orion 100A IP67 DC-DC Converter today for reliable, uninterrupted power delivery.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOrion IP67\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e24\/12-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eInput voltage range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e18-35VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage shutdown\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e15V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage restart\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e16V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNo load current at 24V\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e85mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDC output voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e12V +\/- 3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum continuous output current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEfficiency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eRipple \u0026amp; Noise\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e150mVpp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-40 to +70°C (full rated output up to 40°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOverload protection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eHiccup mode, recovers automatically after fault condition is removed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eShort circuit proof\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eProtection against reverse polarity connection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eWith external fuse or circuit breaker (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaterial \u0026amp; Colour\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eAluminium (blue RAL 5012)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eProtection category\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDC connection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eBolts M6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCable cross section, input\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003en.a.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCable cross section, output\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003en.a.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight (kg)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e2.15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions (h x w x d in mm)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e265 x 127 x 63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eSafety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 60950\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEmission\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-3, EN 55014-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eImmunity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 55014-2, EN 61000-6-1, EN 61000-6-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eVibration\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eIEC 68-2-6: 10-150 Hz \/ 1.0 G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364386664731,"sku":"VIC-ORI241221226","price":309.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/VIC-ORI241221226-01.jpg?v=1781658337"},{"product_id":"victron-orion-ip67-24v-to-12v-10a-non-isolated-waterproof-dc-dc-converter","title":"Victron Energy - 24V to 12V - 10A - Orion 24\/12-10A Non-Isolated IP67 - DC-DC Converter","description":"\u003ch2\u003eVictron 24V to 12V Orion 24\/12-10A (120W) Non-Isolated IP67 DC-DC Converter\u003c\/h2\u003e \u003ch3\u003eCompletely Encapsulated for Ultimate Protection\u003c\/h3\u003e \u003cp\u003eThe Victron Orion 24V to 12V DC-DC Converter is designed to withstand the toughest conditions, making it an ideal choice for demanding environments. Its encapsulated design ensures that it is:\u003c\/p\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eWaterproof:\u003c\/strong\u003e Perfect for marine applications or areas prone to water exposure.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eShockproof:\u003c\/strong\u003e Can endure harsh vibrations, ideal for industrial and mobile applications.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eIgnition Protected:\u003c\/strong\u003e Safe to use in environments where sparks could pose a danger.\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eBuilt to Withstand Elements\u003c\/h3\u003e \u003cp\u003eConstructed with a robust cast aluminium casing and electronics moulded in resin, this converter is highly resistant to water, oil, and dirt. You can trust the Orion IP67 DC-DC Converter to perform reliably in the harshest conditions.\u003c\/p\u003e \u003ch3\u003eExtra-Long Input and Output Cables\u003c\/h3\u003e \u003cp\u003eFeaturing 1.8-meter input and output cables, the Victron Orion converter eliminates the need for additional cable interconnections in most setups. This not only simplifies installation but also enhances reliability by reducing potential points of failure.\u003c\/p\u003e \u003ch3\u003eWide Input Voltage Range\u003c\/h3\u003e \u003cp\u003eWith a wide input voltage range of 15 to 40 volts, this converter ensures a stable 12V output even during voltage surges or drops, providing consistent power to your equipment.\u003c\/p\u003e \u003ch3\u003eOverheating Protection\u003c\/h3\u003e \u003cp\u003eDesigned to operate efficiently in hot environments, such as machine rooms, the Orion converter includes overheating protection to ensure safe and reliable performance.\u003c\/p\u003e \u003ch3\u003eIdeal Applications\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eCaravans:\u003c\/strong\u003e Reliable power conversion for onboard electronics.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eRVs:\u003c\/strong\u003e Robust and weatherproof for outdoor adventures.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMarine:\u003c\/strong\u003e Waterproof design perfect for boats and yachts.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eOff-Grid:\u003c\/strong\u003e Stable power supply for remote installations.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eIndustrial:\u003c\/strong\u003e Durable and shockproof for factory and machinery use.\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eUpgrade Your Power System Today!\u003c\/h3\u003e \u003cp\u003eEnsure your power system is reliable and efficient with the Victron 24V to 12V Orion 24\/12-10A Non-Isolated IP67 DC-DC Converter. \u003cstrong\u003eOrder now\u003c\/strong\u003e to experience ultimate protection and performance in any environment!\u003c\/p\u003e \n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOrion IP67\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e24\/12-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eInput voltage range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e15-40VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage shutdown\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e13V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage restart\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e14V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNo load current at 24V\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e20mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDC output voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e12V +\/- 3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum continuous output current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e10A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEfficiency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e93%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eRipple \u0026amp; Noise\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e75mVpp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-40 to +70°C (full rated output up to 40°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOverload protection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eHiccup mode, recovers automatically after fault condition is removed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eShort circuit proof\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eProtection against reverse polarity connection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eWith external fuse or circuit breaker (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaterial \u0026amp; Colour\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eAluminium (blue RAL 5012)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eProtection category\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDC connection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eTwo input and two output cables, length 1.8m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCable cross section, input\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e1.5mm² (15 AWG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCable cross section, output\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e1.5mm² (15 AWG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight (kg)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e300 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions (h x w x d in mm)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e74 x 74 x 32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eSafety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 60950\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEmission\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-3, EN 55014-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eImmunity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 55014-2, EN 61000-6-1, EN 61000-6-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eVibration\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eIEC 68-2-6: 10-150 Hz \/ 1.0 G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364386959643,"sku":"Vic-ORI241210260","price":47.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/Vic-ORI241210260-01.jpg?v=1781658175"},{"product_id":"victron-orion-ip67-24v-to-12v-20a-non-isolated-waterproof-dc-dc-converter","title":"Victron Energy - 24V to 12V - 20A - Orion 24\/12-20A Non-Isolated IP67 - DC-DC Converter","description":"\u003ch2\u003eVictron 24V to 12V Orion 24\/12-20A (240W) Non-Isolated IP67 DC-DC Converter\u003c\/h2\u003e \u003ch3\u003eSuperior Durability and Protection\u003c\/h3\u003e \u003cp\u003eThe Victron 24V to 12V Orion 24\/12-20A Non-Isolated IP67 DC-DC Converter is designed for the toughest conditions. Completely encapsulated, this converter is waterproof, shockproof, and ignition protected, ensuring that water, oil, or dirt won't damage it. The robust cast aluminium casing, combined with electronics moulded in resin, provides unparalleled durability for your critical applications.\u003c\/p\u003e \u003ch3\u003eKey Features\u003c\/h3\u003e \u003ch4\u003eFully Encapsulated Design\u003c\/h4\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eWaterproof\u003c\/strong\u003e: Safeguards against water intrusion, perfect for marine or off-grid setups.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eShockproof\u003c\/strong\u003e: Resilient against mechanical shocks and vibrations, ideal for industrial and mobile applications.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eIgnition Protected\u003c\/strong\u003e: Ensures safety in volatile environments, making it suitable for various applications including RVs and caravans.\u003c\/li\u003e \u003c\/ul\u003e \u003ch4\u003eLong Input and Output Cables\u003c\/h4\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003e1.8 Meters Length\u003c\/strong\u003e: Extra-long cables minimize the need for additional interconnections, enhancing reliability.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSimplified Installation\u003c\/strong\u003e: Reduces complexity and potential points of failure in your setup, especially important in IP67 rated environments.\u003c\/li\u003e \u003c\/ul\u003e \u003ch4\u003eWide Input Voltage Range\u003c\/h4\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003e15 to 40 Volts\u003c\/strong\u003e: Ensures stable output even during voltage surges or sags, providing consistent performance.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eVersatile Compatibility\u003c\/strong\u003e: Supports a range of power sources, making it adaptable to various setups and battery conditions.\u003c\/li\u003e \u003c\/ul\u003e \u003ch4\u003eOverheating Protection\u003c\/h4\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eHeat Resistant\u003c\/strong\u003e: Operates efficiently in high-temperature environments like machine rooms.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSafety and Reliability\u003c\/strong\u003e: Protects against thermal overload, ensuring continuous operation without risk of overheating.\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eIdeal Applications\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eCaravans and RVs\u003c\/strong\u003e: Reliable power conversion for your mobile lifestyle.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMarine\u003c\/strong\u003e: Durable and waterproof for boating and marine applications.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eOff-Grid Systems\u003c\/strong\u003e: Perfect for remote locations where reliable power conversion is crucial.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eIndustrial\u003c\/strong\u003e: Withstands harsh industrial environments, ensuring continuous operation.\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eEnhance Your Setup Today\u003c\/h3\u003e \u003cp\u003eUpgrade your power system with the Victron 24V to 12V Orion 24\/12-20A Non-Isolated IP67 DC-DC Converter. Ensure your equipment is protected and operates reliably in any condition. Order now and experience the difference in durability and performance.\u003c\/p\u003e \n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOrion IP67\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e24\/12-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eInput voltage range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e15-40VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage shutdown\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e13V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage restart\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e14V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNo load current at 24V\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e50mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDC output voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e12V +\/- 3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum continuous output current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEfficiency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eRipple \u0026amp; Noise\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e75mVpp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-40 to +70°C (full rated output up to 40°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOverload protection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eHiccup mode, recovers automatically after fault condition is removed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eShort circuit proof\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eProtection against reverse polarity connection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eWith external fuse or circuit breaker (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaterial \u0026amp; Colour\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eAluminium (blue RAL 5012)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eProtection category\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDC connection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eTwo input and two output cables, length 1.8m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCable cross section, input\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e2.6mm² (13 AWG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCable cross section, output\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e2.6mm² (13 AWG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight (kg)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e0.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions (h x w x d in mm)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e74 x 74 x 32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eSafety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 60950\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEmission\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-3, EN 55014-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eImmunity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 55014-2, EN 61000-6-1, EN 61000-6-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eVibration\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eIEC 68-2-6: 10-150 Hz \/ 1.0 G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364387385627,"sku":"VIC-ORI241220260","price":58.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/VIC-ORI241220260-01.jpg?v=1781658177"},{"product_id":"victron-orion-ip67-24v-to-12v-5a-non-isolated-waterproof-dc-dc-converter","title":"Victron Energy - 24V to 12V - 5A - Orion 24\/12-5A Non-Isolated IP67 - DC-DC Converter","description":"\u003ch2\u003eVictron 24V to 12V Orion 24\/12-5A (60W) Non-Isolated IP67 DC-DC Converter\u003c\/h2\u003e \u003ch3\u003eUnmatched Durability and Protection\u003c\/h3\u003e \u003cp\u003eThe Victron Orion 24V to 12V DC-DC Converter is designed for the toughest environments. This unit is completely encapsulated, making it waterproof, shockproof, and ignition protected. Whether it's water, oil, or dirt, the Orion IP67 DC-DC Converter remains undamaged. The cast aluminium casing and resin-moulded electronics ensure robust and reliable performance, providing peace of mind in demanding conditions.\u003c\/p\u003e \u003ch3\u003eKey Features\u003c\/h3\u003e \u003ch4\u003eWaterproof, Shockproof, and Ignition Protected\u003c\/h4\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eEncapsulated Design:\u003c\/strong\u003e With its IP67 rating, this converter is impervious to water, oil, and dirt.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Made with a cast aluminium casing and resin-moulded electronics.\u003c\/li\u003e \u003c\/ul\u003e \u003ch4\u003eExtra-Long Input and Output Cables\u003c\/h4\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003e1.8 Meter Cables:\u003c\/strong\u003e Eliminate the need for intermediate cable connections, enhancing reliability.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eEase of Installation:\u003c\/strong\u003e Simplifies setup by reducing the need for additional extensions.\u003c\/li\u003e \u003c\/ul\u003e \u003ch4\u003eWide Input Voltage Range\u003c\/h4\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eVersatile Voltage Handling:\u003c\/strong\u003e Operates efficiently within a 15 to 40 Volts input range.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eStable Output:\u003c\/strong\u003e Maintains a steady 12V output even during voltage surges or sags from other connected equipment.\u003c\/li\u003e \u003c\/ul\u003e \u003ch4\u003eOverheat Protection\u003c\/h4\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eHeat Resistance:\u003c\/strong\u003e Suitable for use in high-temperature environments such as machine rooms.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eReliable Performance:\u003c\/strong\u003e Continues to operate efficiently without risk of overheating.\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eApplications\u003c\/h3\u003e \u003cp\u003eThe Victron 24V to 12V Orion DC-DC Converter is ideal for a wide range of applications, including:\u003c\/p\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eCaravans and RVs:\u003c\/strong\u003e Ensures reliable power conversion for on-the-go power needs.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMarine:\u003c\/strong\u003e Perfect for boats and other marine environments where waterproof equipment is essential.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eOff-Grid Systems:\u003c\/strong\u003e Enhances the reliability of power systems in remote locations.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eIndustrial:\u003c\/strong\u003e Suitable for heavy-duty industrial use, providing stable power conversion in challenging conditions.\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eWhy Choose the Victron Orion 24V to 12V DC-DC Converter?\u003c\/h3\u003e \u003cp\u003eInvest in the Victron Orion 24\/12-5A Non-Isolated IP67 DC-DC Converter for unbeatable durability and performance. Its advanced protection features, combined with the extra-long cables and wide input range, make it a top choice for various applications. Upgrade your vehicle or off-grid system now to experience reliable power conversion in even the harshest environments!\u003c\/p\u003e \u003cp\u003eDon't wait – ensure your power system's reliability with the Victron Orion today!\u003c\/p\u003e \n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOrion IP67\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e24\/12-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eInput voltage range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e15-40VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage shutdown\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e13V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage restart\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e14V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNo load current at 24V\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e1mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDC output voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e12V +\/- 3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum continuous output current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEfficiency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e93%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eRipple \u0026amp; Noise\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e75mVpp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-40 to +70°C (full rated output up to 40°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOverload protection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eHiccup mode, recovers automatically after fault condition is removed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eShort circuit proof\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eProtection against reverse polarity connection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eWith external fuse or circuit breaker (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaterial \u0026amp; Colour\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eAluminium (blue RAL 5012)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eProtection category\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDC connection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eTwo input and two output cables, length 1.8m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCable cross section, input\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e0.8mm² (18 AWG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCable cross section, output\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e0.8mm² (18 AWG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight (kg)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e50 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions (h x w x d in mm)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e25 x 43 x 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eSafety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 60950\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEmission\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-3, EN 55014-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eImmunity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 55014-2, EN 61000-6-1, EN 61000-6-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eVibration\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eIEC 68-2-6: 10-150 Hz \/ 1.0 G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364387516699,"sku":"VIC-ORI241205260","price":32.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/VIC-ORI241205260-01.jpg?v=1781658175"},{"product_id":"victron-orion-tr-12v-to-12v-18a-isolated-dc-dc-converter","title":"Victron Energy - 12V to 12V - Orion-Tr - 12\/12-18A - Isolated DC-DC Converter","description":"\u003ch2\u003eVictron Orion-Tr 12\/12-18A Isolated DC-DC Converter: Clean, Stable Power for Sensitive Electronics\u003c\/h2\u003e\n\u003ch3\u003eGalvanic Isolation for Superior Noise Rejection and System Protection\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eVictron Orion-Tr 12\/12-18A\u003c\/strong\u003e delivers a regulated, isolated DC output, making it the ideal solution for powering sensitive loads where electrical noise and ground loops cannot be tolerated. Unlike non-isolated converters, this unit provides \u003cstrong\u003e200V DC galvanic isolation\u003c\/strong\u003e between input, output, and case, effectively breaking ground loops and suppressing interference. This is critical for \u003cstrong\u003emarine electronics\u003c\/strong\u003e, \u003cstrong\u003ecommunications equipment\u003c\/strong\u003e, and \u003cstrong\u003eindustrial sensors\u003c\/strong\u003e where signal integrity is paramount.\u003c\/p\u003e\n\u003cp\u003eWith a wide input voltage range of 8-17V, it maintains a stable output even when the source voltage fluctuates, protecting your equipment from brownouts and surges. The output voltage is fully adjustable from 10-15V, allowing precise matching to your load requirements.\u003c\/p\u003e\n\u003ch3\u003eEngineered for Demanding Environments\u003c\/h3\u003e\n\u003cp\u003eBuilt on Victron's proven Orion platform, this converter features a rugged, compact design with an \u003cstrong\u003eIP43 protection rating\u003c\/strong\u003e when installed with terminals facing downwards. Mounted in a dry, protected location (humidity max. 95% non-condensing), it suits \u003cstrong\u003eoff-grid solar systems\u003c\/strong\u003e, \u003cstrong\u003evehicle-based installations\u003c\/strong\u003e and \u003cstrong\u003eboats\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003ePassive cooling via an integrated aluminium heatsink eliminates noisy fans and moving parts, reducing maintenance and points of failure. The wide operating temperature range of -20 to +55°C (derating above 40°C) ensures consistent performance across Australia's diverse climates, from the tropical north to the arid interior.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic isolation (200V DC)\u003c\/strong\u003e between input, output, and case eliminates ground loops and protects sensitive electronics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide input voltage range\u003c\/strong\u003e (8-17V) with under-voltage shutdown and restart for battery protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable output voltage\u003c\/strong\u003e (10-15V) for precise load matching\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote on\/off control\u003c\/strong\u003e via low-power switch eliminates need for high-current input wiring switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort circuit proof\u003c\/strong\u003e and capable of unlimited parallel connection for higher current demands\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh efficiency\u003c\/strong\u003e up to 87% reduces heat generation and wasted energy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP43 protection\u003c\/strong\u003e when installed with terminals downwards, for a dry, protected mounting location\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact and lightweight\u003c\/strong\u003e design with integrated heatsink for fanless operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScrew terminals\u003c\/strong\u003e accept cables up to 16 mm² for secure, low-resistance connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications Where Clean Power Matters\u003c\/h3\u003e\n\u003cp\u003eThis isolated DC-DC converter excels in scenarios where voltage stability and noise immunity are non-negotiable:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine electronics:\u003c\/strong\u003e Power navigation systems, autopilots, and communication radios without interference from engine alternators or inverters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCaravans and RVs:\u003c\/strong\u003e Provide stable 12V to sensitive appliances like compressor fridges, LED lighting, and entertainment systems, regardless of battery voltage sag.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-grid solar systems:\u003c\/strong\u003e Supply clean, isolated power to monitoring and control equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial and laboratory equipment:\u003c\/strong\u003e Isolate sensitive measurement instruments from noisy DC bus voltages in factories or test benches.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTelecommunications:\u003c\/strong\u003e Ensure reliable operation of remote radio repeaters and networking gear with a regulated, isolated supply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Choose an Isolated Converter?\u003c\/h3\u003e\n\u003cp\u003eStandard non-isolated DC-DC converters share a common ground between input and output, which can introduce electrical noise, ground loops, and potential damage to sensitive electronics. The Victron Orion-Tr isolated series breaks this connection, providing a 'floating' output that is electrically independent. This is especially important in vehicles and boats where multiple charging sources and varying ground potentials can cause erratic behaviour in connected devices.\u003c\/p\u003e\n\u003cp\u003eAdditionally, the adjustable output voltage allows this converter to be used as a \u003cstrong\u003econstant voltage power supply\u003c\/strong\u003e for equipment that requires a specific voltage, such as LED lighting systems or certain telecommunications gear. Note: This unit is a DC-DC converter, not a multi-stage battery charger. For battery charging applications, see the Victron Orion-Tr Smart Charger range.\u003c\/p\u003e\n\u003ch3\u003eInstallation and Integration\u003c\/h3\u003e\n\u003cp\u003eInstallation is straightforward with clearly labelled screw terminals and a removable green remote on\/off connector. The remote port can be wired to a vehicle's ignition switch, a manual toggle, or a BMS control signal, allowing automated power management. The compact footprint and multiple mounting points make it easy to fit into existing electrical enclosures or tight spaces.\u003c\/p\u003e\n\u003cp\u003eFor higher power requirements, multiple units can be connected in parallel with no practical limit, providing a scalable solution that grows with your system.\u003c\/p\u003e\n\u003ch3\u003ePower Your Critical Systems with Confidence\u003c\/h3\u003e\n\u003cp\u003eWhen clean, stable DC power is essential, trust the \u003cstrong\u003eVictron Orion-Tr 12\/12-18A\u003c\/strong\u003e to deliver. Whether you're outfitting a bluewater yacht, a remote off-grid cabin, or a mobile command vehicle, this isolated converter provides the reliability and performance that professionals demand. Add it to your power system today and eliminate electrical noise for good.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eOrion-Tr 12\/12-18 (220 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eInput voltage range (1)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e8-17 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage shut down\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e7 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage restart\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e7.5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNominal output voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e12.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage adjust range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e10-15 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage tolerance\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e+\/- 0.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput noise\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e2 mV rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output current at nominal output voltage and 40 °C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e18 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum output current (10 s) at nominal output voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eShort circuit output current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output power at 25 °C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e280 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output power at 40 °C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e220 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEfficiency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e87%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNo load input current (2)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 80 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCurrent consumption\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 200uA when disabled via its remote port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eGalvanic isolation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e200 VDC between input, output and case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-20 to +55 °C (derate 3 % per °C above 40 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eHumidity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eMax. 95 % non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDC connection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum cable cross-section\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e16 mm2 AWG6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e1.3 kg (3 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions h x w x d\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e130 x 186 x 70 mm (5.1 x 7.3 x 2.8 inch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards: Safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 60950\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards: Emission\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-3, EN 55014-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards: Immunity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-2, EN 61000-6-1, EN 55014-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards: Automotive Directive\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eECE R10-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364388008219,"sku":"VIC-ORI121222110","price":159.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/VIC-ORI121222110-01.jpg?v=1781658164"},{"product_id":"victron-orion-tr-12v-to-12v-30a-isolated-dc-dc-converter","title":"Victron Energy - 12V to 12V - Orion-Tr - 12\/12-30A - Isolated DC-DC Converter","description":"\u003ch2\u003eVictron Orion-Tr 12\/12-30A Isolated DC-DC Converter: Clean, Stable Power for Sensitive Electronics\u003c\/h2\u003e\n\u003ch3\u003eGalvanic Isolation for Superior Noise Rejection and System Protection\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eVictron Orion-Tr 12\/12-30A\u003c\/strong\u003e delivers a regulated, isolated DC output, making it the ideal solution for powering sensitive loads where electrical noise and ground loops cannot be tolerated. Unlike non-isolated converters, this unit provides \u003cstrong\u003e200V DC galvanic isolation\u003c\/strong\u003e between input, output, and case, effectively breaking ground loops and suppressing interference. This is critical for \u003cstrong\u003emarine electronics\u003c\/strong\u003e, \u003cstrong\u003ecommunications equipment\u003c\/strong\u003e, and \u003cstrong\u003eindustrial sensors\u003c\/strong\u003e where signal integrity is paramount.\u003c\/p\u003e\n\u003cp\u003eWith a wide input voltage range of 10-17V, it maintains a stable output even when the source voltage fluctuates, protecting your equipment from brownouts and surges. The output voltage is fully adjustable from 10-15V, allowing precise matching to your load requirements.\u003c\/p\u003e\n\u003ch3\u003eEngineered for Demanding Environments\u003c\/h3\u003e\n\u003cp\u003eBuilt on Victron's proven Orion platform, this converter features a rugged, compact design with an \u003cstrong\u003eIP43 protection rating\u003c\/strong\u003e when installed with terminals facing downwards. Mounted in a dry, protected location (humidity max. 95% non-condensing), it suits \u003cstrong\u003eoff-grid solar systems\u003c\/strong\u003e, \u003cstrong\u003evehicle-based installations\u003c\/strong\u003e and \u003cstrong\u003eboats\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003ePassive cooling via an integrated aluminium heatsink eliminates noisy fans and moving parts, reducing maintenance and points of failure. The wide operating temperature range of -20 to +55°C (derating above 40°C) ensures consistent performance across Australia's diverse climates, from the tropical north to the arid interior.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic isolation (200V DC)\u003c\/strong\u003e between input, output, and case eliminates ground loops and protects sensitive electronics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide input voltage range\u003c\/strong\u003e (10-17V) with under-voltage shutdown and restart for battery protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable output voltage\u003c\/strong\u003e (10-15V) for precise load matching\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote on\/off control\u003c\/strong\u003e via low-power switch eliminates need for high-current input wiring switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort circuit proof\u003c\/strong\u003e and capable of unlimited parallel connection for higher current demands\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh efficiency\u003c\/strong\u003e up to 87% reduces heat generation and wasted energy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP43 protection\u003c\/strong\u003e when installed with terminals downwards, for a dry, protected mounting location\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact and lightweight\u003c\/strong\u003e design with integrated heatsink for fanless operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScrew terminals\u003c\/strong\u003e accept cables up to 16 mm² (AWG6) for secure, low-resistance connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications Where Clean Power Matters\u003c\/h3\u003e\n\u003cp\u003eThis isolated DC-DC converter excels in scenarios where voltage stability and noise immunity are non-negotiable:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine electronics:\u003c\/strong\u003e Power navigation systems, autopilots, and communication radios without interference from engine alternators or inverters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCaravans and RVs:\u003c\/strong\u003e Provide stable 12V to sensitive appliances like compressor fridges, LED lighting, and entertainment systems, regardless of battery voltage sag.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-grid solar systems:\u003c\/strong\u003e Supply clean, isolated power to monitoring and control equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial and laboratory equipment:\u003c\/strong\u003e Isolate sensitive measurement instruments from noisy DC bus voltages in factories or test benches.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTelecommunications:\u003c\/strong\u003e Ensure reliable operation of remote radio repeaters and networking gear with a regulated, isolated supply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Choose an Isolated Converter?\u003c\/h3\u003e\n\u003cp\u003eStandard non-isolated DC-DC converters share a common ground between input and output, which can introduce electrical noise, ground loops, and potential damage to sensitive electronics. The Victron Orion-Tr isolated series breaks this connection, providing a 'floating' output that is electrically independent. This is especially important in vehicles and boats where multiple charging sources and varying ground potentials can cause erratic behaviour in connected devices.\u003c\/p\u003e\n\u003cp\u003eAdditionally, the adjustable output voltage allows this converter to be used as a \u003cstrong\u003econstant voltage power supply\u003c\/strong\u003e for equipment that requires a specific voltage, such as LED lighting systems or certain telecommunications gear. Note: This unit is a DC-DC converter, not a multi-stage battery charger. For battery charging applications, see the Victron Orion-Tr Smart Charger range.\u003c\/p\u003e\n\u003ch3\u003eInstallation and Integration\u003c\/h3\u003e\n\u003cp\u003eInstallation is straightforward with clearly labelled screw terminals and a removable green remote on\/off connector. The remote port can be wired to a vehicle's ignition switch, a manual toggle, or a BMS control signal, allowing automated power management. The compact footprint and multiple mounting points make it easy to fit into existing electrical enclosures or tight spaces.\u003c\/p\u003e\n\u003cp\u003eFor higher power requirements, multiple units can be connected in parallel with no practical limit, providing a scalable solution that grows with your system.\u003c\/p\u003e\n\u003ch3\u003ePower Your Critical Systems with Confidence\u003c\/h3\u003e\n\u003cp\u003eWhen clean, stable DC power is essential, trust the \u003cstrong\u003eVictron Orion-Tr 12\/12-30A\u003c\/strong\u003e to deliver. Whether you're outfitting a bluewater yacht, a remote off-grid cabin, or a mobile command vehicle, this isolated converter provides the reliability and performance that professionals demand. Add it to your power system today and eliminate electrical noise for good.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eOrion-Tr 12\/12-30 (360 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eInput voltage range (1)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e10-17 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage shut down\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e7 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage restart\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e7.5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNominal output voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e12.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage adjust range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e10-15 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage tolerance\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e+\/- 0.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput noise\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e2 mV rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output current at nominal output voltage and 40°C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum output current (10 s) at nominal output voltage minus 20%\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eShort circuit output current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e60 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output power at 25°C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e430 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output power at 40°C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e360 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEfficiency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e87%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNo load input current (2)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 80 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCurrent consumption\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 200uA when disabled via its remote port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eGalvanic isolation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e200 VDC between input, output and case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-20 to +55 °C (derate 3 % per °C above 40 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eHumidity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eMax. 95 % non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDC connection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum cable cross-section\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e16 mm2 AWG6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e1.8 kg (4 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions hxwxd\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e130 x 186 x 80 mm (5.1 x 7.3 x 3.2 inch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards: Safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 60950\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEmission\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-3, EN 55014-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eImmunity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-2, EN 61000-6-1, EN 55014-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eAutomotive Directive\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eECE R10-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364388204827,"sku":"VIC-ORI121240110","price":269.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/VIC-ORI121240110-01.jpg?v=1781658177"},{"product_id":"victron-orion-tr-12v-to-12v-9a-isolated-dc-dc-converter","title":"Victron Energy - 12V to 12V - Orion-Tr - 12\/12-9A - Isolated DC-DC Converter","description":"\u003ch2\u003eVictron Orion-Tr 12\/12-9A Isolated DC-DC Converter: Clean, Stable Power for Sensitive Electronics\u003c\/h2\u003e\n\u003ch3\u003eGalvanic Isolation for Superior Noise Rejection and System Protection\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eVictron Orion-Tr 12\/12-9A\u003c\/strong\u003e delivers a regulated, isolated DC output, making it the ideal solution for powering sensitive loads where electrical noise and ground loops cannot be tolerated. Unlike non-isolated converters, this unit provides \u003cstrong\u003e200V DC galvanic isolation\u003c\/strong\u003e between input, output, and case, effectively breaking ground loops and suppressing interference. This is critical for \u003cstrong\u003emarine electronics\u003c\/strong\u003e, \u003cstrong\u003ecommunications equipment\u003c\/strong\u003e, and \u003cstrong\u003eindustrial sensors\u003c\/strong\u003e where signal integrity is paramount.\u003c\/p\u003e\n\u003cp\u003eWith a wide input voltage range of 8-17V, it maintains a stable output even when the source voltage fluctuates, protecting your equipment from brownouts and surges. The output voltage is fully adjustable from 10-15V, allowing precise matching to your load requirements.\u003c\/p\u003e\n\u003ch3\u003eEngineered for Demanding Environments\u003c\/h3\u003e\n\u003cp\u003eBuilt on Victron's proven Orion platform, this converter features a rugged, compact design with an \u003cstrong\u003eIP43 protection rating\u003c\/strong\u003e when installed with terminals facing downwards. Mounted in a dry, protected location (humidity max. 95% non-condensing), it suits \u003cstrong\u003eoff-grid solar systems\u003c\/strong\u003e, \u003cstrong\u003evehicle-based installations\u003c\/strong\u003e and \u003cstrong\u003eboats\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003ePassive cooling via an integrated aluminium heatsink eliminates noisy fans and moving parts, reducing maintenance and points of failure. The wide operating temperature range of -20 to +55°C (derating above 40°C) ensures consistent performance across Australia's diverse climates, from the tropical north to the arid interior.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic isolation (200V DC)\u003c\/strong\u003e between input, output, and case eliminates ground loops and protects sensitive electronics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide input voltage range\u003c\/strong\u003e (8-17V) with under-voltage shutdown and restart for battery protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable output voltage\u003c\/strong\u003e (10-15V) for precise load matching\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote on\/off control\u003c\/strong\u003e via low-power switch eliminates need for high-current input wiring switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort circuit proof\u003c\/strong\u003e and capable of unlimited parallel connection for higher current demands\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh efficiency\u003c\/strong\u003e up to 87% reduces heat generation and wasted energy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP43 protection\u003c\/strong\u003e when installed with terminals downwards, for a dry, protected mounting location\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact and lightweight\u003c\/strong\u003e design with integrated heatsink for fanless operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScrew terminals\u003c\/strong\u003e accept cables up to 6 mm² AWG10 for secure, low-resistance connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications Where Clean Power Matters\u003c\/h3\u003e\n\u003cp\u003eThis isolated DC-DC converter excels in scenarios where voltage stability and noise immunity are non-negotiable:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine electronics:\u003c\/strong\u003e Power navigation systems, autopilots, and communication radios without interference from engine alternators or inverters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCaravans and RVs:\u003c\/strong\u003e Provide stable 12V to sensitive appliances like compressor fridges, LED lighting, and entertainment systems, regardless of battery voltage sag.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-grid solar systems:\u003c\/strong\u003e Supply clean, isolated power to monitoring and control equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial and laboratory equipment:\u003c\/strong\u003e Isolate sensitive measurement instruments from noisy DC bus voltages in factories or test benches.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTelecommunications:\u003c\/strong\u003e Ensure reliable operation of remote radio repeaters and networking gear with a regulated, isolated supply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Choose an Isolated Converter?\u003c\/h3\u003e\n\u003cp\u003eStandard non-isolated DC-DC converters share a common ground between input and output, which can introduce electrical noise, ground loops, and potential damage to sensitive electronics. The Victron Orion-Tr isolated series breaks this connection, providing a 'floating' output that is electrically independent. This is especially important in vehicles and boats where multiple charging sources and varying ground potentials can cause erratic behaviour in connected devices.\u003c\/p\u003e\n\u003cp\u003eAdditionally, the adjustable output voltage allows this converter to be used as a \u003cstrong\u003econstant voltage power supply\u003c\/strong\u003e for equipment that requires a specific voltage, such as LED lighting systems or certain telecommunications gear. Note: This unit is a DC-DC converter, not a multi-stage battery charger. For battery charging applications, see the Victron Orion-Tr Smart Charger range.\u003c\/p\u003e\n\u003ch3\u003eInstallation and Integration\u003c\/h3\u003e\n\u003cp\u003eInstallation is straightforward with clearly labelled screw terminals and a removable green remote on\/off connector. The remote port can be wired to a vehicle's ignition switch, a manual toggle, or a BMS control signal, allowing automated power management. The compact footprint and multiple mounting points make it easy to fit into existing electrical enclosures or tight spaces.\u003c\/p\u003e\n\u003cp\u003eFor higher power requirements, multiple units can be connected in parallel with no practical limit, providing a scalable solution that grows with your system.\u003c\/p\u003e\n\u003ch3\u003ePower Your Critical Systems with Confidence\u003c\/h3\u003e\n\u003cp\u003eWhen clean, stable DC power is essential, trust the \u003cstrong\u003eVictron Orion-Tr 12\/12-9A\u003c\/strong\u003e to deliver. Whether you're outfitting a bluewater yacht, a remote off-grid cabin, or a mobile command vehicle, this isolated converter provides the reliability and performance that professionals demand. Add it to your power system today and eliminate electrical noise for good.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eInput voltage range (1)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e8-17 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage shut down\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e7 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage restart\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e7.5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNominal output voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e12.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage adjust range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e10-15 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage tolerance\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e+\/- 0.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput noise\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e2 mV rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output current at nominal output voltage and 25 °C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum output current (10 s) at nominal output voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e12.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eShort circuit output current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output power at 25 °C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e110 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output power at 40 °C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e85 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEfficiency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e87 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNo load input current (2)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCurrent consumption\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 200 uA when disabled via remote port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eGalvanic isolation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e200 V dc between input, output and case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-20 to +55 °C (derate 3 % per °C above 40 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eHumidity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eMax. 95 % non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDC connection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum cable cross-section\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e6 mm² AWG10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e0.42 kg (1 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions h x w x d\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e100 x 113 x 47 mm (4.0 x 4.5 x 1.9 inch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards: Safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 60950\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEmission\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-3, EN 55014-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eImmunity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-2, EN 61000-6-1, EN 55014-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eAutomotive Directive\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eECE R10-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364388434203,"sku":"VIC-ORI121210110R","price":88.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/Vic-ORI121210110-01.jpg?v=1781658167"},{"product_id":"victron-orion-tr-12v-to-24v-10a-isolated-dc-dc-converter","title":"Victron Energy - 12V to 24V - Orion-Tr - 12\/24-10A - Isolated DC-DC Converter","description":"\u003ch2\u003eVictron Orion-Tr 12\/24-10A Isolated DC-DC Converter: Clean, Stable Power for Sensitive Electronics\u003c\/h2\u003e\n\u003ch3\u003eGalvanic Isolation for Superior Noise Rejection and System Protection\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eVictron Orion-Tr 12\/24-10A\u003c\/strong\u003e delivers a regulated, isolated DC output, making it the ideal solution for powering sensitive loads where electrical noise and ground loops cannot be tolerated. Unlike non-isolated converters, this unit provides \u003cstrong\u003e200V DC galvanic isolation\u003c\/strong\u003e between input, output, and case, effectively breaking ground loops and suppressing interference. This is critical for \u003cstrong\u003emarine electronics\u003c\/strong\u003e, \u003cstrong\u003ecommunications equipment\u003c\/strong\u003e, and \u003cstrong\u003eindustrial sensors\u003c\/strong\u003e where signal integrity is paramount.\u003c\/p\u003e\n\u003cp\u003eWith a wide input voltage range of 8-17V, it maintains a stable output even when the source voltage fluctuates, protecting your equipment from brownouts and surges. The output voltage is fully adjustable from 20-30V, allowing precise matching to your load requirements.\u003c\/p\u003e\n\u003ch3\u003eEngineered for Demanding Environments\u003c\/h3\u003e\n\u003cp\u003eBuilt on Victron's proven Orion platform, this converter features a rugged, compact design with an \u003cstrong\u003eIP43 protection rating\u003c\/strong\u003e when installed with terminals facing downwards. Mounted in a dry, protected location (humidity max. 95% non-condensing), it suits \u003cstrong\u003eoff-grid solar systems\u003c\/strong\u003e, \u003cstrong\u003evehicle-based installations\u003c\/strong\u003e and \u003cstrong\u003eboats\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003ePassive cooling via an integrated aluminium heatsink eliminates noisy fans and moving parts, reducing maintenance and points of failure. The wide operating temperature range of -20 to +55°C (derating above 40°C) ensures consistent performance across Australia's diverse climates, from the tropical north to the arid interior.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic isolation (200V DC)\u003c\/strong\u003e between input, output, and case eliminates ground loops and protects sensitive electronics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide input voltage range\u003c\/strong\u003e (8-17V) with under-voltage shutdown and restart for battery protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable output voltage\u003c\/strong\u003e (20-30V) for precise load matching\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote on\/off control\u003c\/strong\u003e via low-power switch eliminates need for high-current input wiring switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort circuit proof\u003c\/strong\u003e and capable of unlimited parallel connection for higher current demands\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh efficiency\u003c\/strong\u003e up to 88% reduces heat generation and wasted energy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP43 protection\u003c\/strong\u003e when installed with terminals downwards, for a dry, protected mounting location\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact and lightweight\u003c\/strong\u003e design with integrated heatsink for fanless operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScrew terminals\u003c\/strong\u003e accept cables up to 16 mm² (AWG6) for secure, low-resistance connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications Where Clean Power Matters\u003c\/h3\u003e\n\u003cp\u003eThis isolated DC-DC converter excels in scenarios where voltage stability and noise immunity are non-negotiable:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine electronics:\u003c\/strong\u003e Power navigation systems, autopilots, and communication radios without interference from engine alternators or inverters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCaravans and RVs:\u003c\/strong\u003e Provide stable 24V to sensitive appliances like compressor fridges, LED lighting, and entertainment systems, regardless of battery voltage sag.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-grid solar systems:\u003c\/strong\u003e Step voltage up between battery banks of different voltages, or supply clean power to monitoring and control equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial and laboratory equipment:\u003c\/strong\u003e Isolate sensitive measurement instruments from noisy DC bus voltages in factories or test benches.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTelecommunications:\u003c\/strong\u003e Ensure reliable operation of remote radio repeaters and networking gear with a regulated, isolated supply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Choose an Isolated Converter?\u003c\/h3\u003e\n\u003cp\u003eStandard non-isolated DC-DC converters share a common ground between input and output, which can introduce electrical noise, ground loops, and potential damage to sensitive electronics. The Victron Orion-Tr isolated series breaks this connection, providing a 'floating' output that is electrically independent. This is especially important in vehicles and boats where multiple charging sources and varying ground potentials can cause erratic behaviour in connected devices.\u003c\/p\u003e\n\u003cp\u003eAdditionally, the adjustable output voltage allows this converter to be used as a \u003cstrong\u003econstant voltage power supply\u003c\/strong\u003e for equipment that requires a specific voltage, such as LED lighting systems or certain telecommunications gear. Note: This unit is a DC-DC converter, not a multi-stage battery charger. For battery charging applications, see the Victron Orion-Tr Smart Charger range.\u003c\/p\u003e\n\u003ch3\u003eInstallation and Integration\u003c\/h3\u003e\n\u003cp\u003eInstallation is straightforward with clearly labelled screw terminals and a removable green remote on\/off connector. The remote port can be wired to a vehicle's ignition switch, a manual toggle, or a BMS control signal, allowing automated power management. The compact footprint and multiple mounting points make it easy to fit into existing electrical enclosures or tight spaces.\u003c\/p\u003e\n\u003cp\u003eFor higher power requirements, multiple units can be connected in parallel with no practical limit, providing a scalable solution that grows with your system.\u003c\/p\u003e\n\u003ch3\u003ePower Your Critical Systems with Confidence\u003c\/h3\u003e\n\u003cp\u003eWhen clean, stable DC power is essential, trust the \u003cstrong\u003eVictron Orion-Tr 12\/24-10A\u003c\/strong\u003e to deliver. Whether you're outfitting a bluewater yacht, a remote off-grid cabin, or a mobile command vehicle, this isolated converter provides the reliability and performance that professionals demand. Add it to your power system today and eliminate electrical noise for good.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eOrion-Tr 12\/24-10 (240 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eInput voltage range (1)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e8-17 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage shut down\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e7 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage restart\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e7.5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNominal output voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e24.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage adjust range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e20-30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage tolerance\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e+\/- 0.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput noise\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e2 mV rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output current at nominal output voltage and 40 °C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e10A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum output current (10 s) at nominal output voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eShort circuit output current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output power at 25 °C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e280 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output power at 40 °C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e240 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEfficiency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e88%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNo load input current (2)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCurrent consumption\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 200uA when disabled via its remote port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eGalvanic isolation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e200 VDC between input, output and case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-20 to +55 °C (derate 3 % per °C above 40 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eHumidity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eMax. 95 % non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDC connection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum cable cross-section\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e16 mm2 AWG6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e1.3 kg (3 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions h x w x d\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e130 x 186 x 70 mm (5.1 x 7.3 x 2.8 inch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards: Safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 60950\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards: Emission\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-3, EN 55014-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards: Immunity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-2, EN 61000-6-1, EN 55014-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards: Automotive Directive\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eECE R10-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364388565275,"sku":"Vic-ORI122424110","price":154.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/Vic-ORI122424110-01.jpg?v=1781658165"},{"product_id":"victron-orion-tr-12v-to-24v-15a-isolated-dc-dc-converter","title":"Victron Energy - 12V to 24V - Orion-Tr - 12\/24-15A - Isolated DC-DC Converter","description":"\u003ch2\u003eVictron Orion-Tr 12\/24-15 Isolated DC-DC Converter: Clean, Stable Power for Sensitive Electronics\u003c\/h2\u003e\n\u003ch3\u003eGalvanic Isolation for Superior Noise Rejection and System Protection\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eVictron Orion-Tr 12\/24-15\u003c\/strong\u003e delivers a regulated, isolated DC output, making it the ideal solution for powering sensitive loads where electrical noise and ground loops cannot be tolerated. Unlike non-isolated converters, this unit provides \u003cstrong\u003e200V DC galvanic isolation\u003c\/strong\u003e between input, output, and case, effectively breaking ground loops and suppressing interference. This is critical for \u003cstrong\u003emarine electronics\u003c\/strong\u003e, \u003cstrong\u003ecommunications equipment\u003c\/strong\u003e, and \u003cstrong\u003eindustrial sensors\u003c\/strong\u003e where signal integrity is paramount.\u003c\/p\u003e\n\u003cp\u003eWith a wide input voltage range of 10-17V, it maintains a stable output even when the source voltage fluctuates, protecting your equipment from brownouts and surges. The output voltage is fully adjustable from 20-30V, allowing precise matching to your load requirements.\u003c\/p\u003e\n\u003ch3\u003eEngineered for Demanding Environments\u003c\/h3\u003e\n\u003cp\u003eBuilt on Victron's proven Orion platform, this converter features a rugged, compact design with an \u003cstrong\u003eIP43 protection rating\u003c\/strong\u003e when installed with terminals facing downwards. Mounted in a dry, protected location (humidity max. 95% non-condensing), it suits \u003cstrong\u003eoff-grid solar systems\u003c\/strong\u003e, \u003cstrong\u003evehicle-based installations\u003c\/strong\u003e and \u003cstrong\u003eboats\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003ePassive cooling via an integrated aluminium heatsink eliminates noisy fans and moving parts, reducing maintenance and points of failure. The wide operating temperature range of -20 to +55°C (derating above 40°C) ensures consistent performance across Australia's diverse climates, from the tropical north to the arid interior.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic isolation (200V DC)\u003c\/strong\u003e between input, output, and case eliminates ground loops and protects sensitive electronics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide input voltage range\u003c\/strong\u003e (10-17V) with under-voltage shutdown and restart for battery protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable output voltage\u003c\/strong\u003e (20-30V) for precise load matching\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote on\/off control\u003c\/strong\u003e via low-power switch eliminates need for high-current input wiring switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort circuit proof\u003c\/strong\u003e and capable of unlimited parallel connection for higher current demands\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh efficiency\u003c\/strong\u003e up to 88% reduces heat generation and wasted energy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP43 protection\u003c\/strong\u003e when installed with terminals downwards, for a dry, protected mounting location\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact and lightweight\u003c\/strong\u003e design with integrated heatsink for fanless operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScrew terminals\u003c\/strong\u003e accept cables up to 16 mm² (AWG6) for secure, low-resistance connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications Where Clean Power Matters\u003c\/h3\u003e\n\u003cp\u003eThis isolated DC-DC converter excels in scenarios where voltage stability and noise immunity are non-negotiable:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine electronics:\u003c\/strong\u003e Power navigation systems, autopilots, and communication radios without interference from engine alternators or inverters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCaravans and RVs:\u003c\/strong\u003e Provide stable 24V to sensitive appliances like compressor fridges, LED lighting, and entertainment systems, regardless of battery voltage sag.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-grid solar systems:\u003c\/strong\u003e Step voltage up between battery banks of different voltages, or supply clean power to monitoring and control equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial and laboratory equipment:\u003c\/strong\u003e Isolate sensitive measurement instruments from noisy DC bus voltages in factories or test benches.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTelecommunications:\u003c\/strong\u003e Ensure reliable operation of remote radio repeaters and networking gear with a regulated, isolated supply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Choose an Isolated Converter?\u003c\/h3\u003e\n\u003cp\u003eStandard non-isolated DC-DC converters share a common ground between input and output, which can introduce electrical noise, ground loops, and potential damage to sensitive electronics. The Victron Orion-Tr isolated series breaks this connection, providing a 'floating' output that is electrically independent. This is especially important in vehicles and boats where multiple charging sources and varying ground potentials can cause erratic behaviour in connected devices.\u003c\/p\u003e\n\u003cp\u003eAdditionally, the adjustable output voltage allows this converter to be used as a \u003cstrong\u003econstant voltage power supply\u003c\/strong\u003e for equipment that requires a specific voltage, such as LED lighting systems or certain telecommunications gear. Note: This unit is a DC-DC converter, not a multi-stage battery charger. For battery charging applications, see the Victron Orion-Tr Smart Charger range.\u003c\/p\u003e\n\u003ch3\u003eInstallation and Integration\u003c\/h3\u003e\n\u003cp\u003eInstallation is straightforward with clearly labelled screw terminals and a removable green remote on\/off connector. The remote port can be wired to a vehicle's ignition switch, a manual toggle, or a BMS control signal, allowing automated power management. The compact footprint and multiple mounting points make it easy to fit into existing electrical enclosures or tight spaces.\u003c\/p\u003e\n\u003cp\u003eFor higher power requirements, multiple units can be connected in parallel with no practical limit, providing a scalable solution that grows with your system.\u003c\/p\u003e\n\u003ch3\u003ePower Your Critical Systems with Confidence\u003c\/h3\u003e\n\u003cp\u003eWhen clean, stable DC power is essential, trust the \u003cstrong\u003eVictron Orion-Tr 12\/24-15\u003c\/strong\u003e to deliver. Whether you're outfitting a bluewater yacht, a remote off-grid cabin, or a mobile command vehicle, this isolated converter provides the reliability and performance that professionals demand. Add it to your power system today and eliminate electrical noise for good.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eOrion-Tr 12\/24-15 (360 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eInput voltage range (1)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e10-17 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage shut down\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e7 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage restart\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e7.5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNominal output voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e24.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage adjust range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e20-30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage tolerance\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e+\/- 0.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput noise\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e2 mV rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output current at nominal output voltage and 40°C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum output current (10 s) at nominal output voltage minus 20%\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eShort circuit output current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output power at 25°C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e430 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output power at 40°C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e360 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEfficiency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e88%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNo load input current (2)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCurrent consumption\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 200uA when disabled via its remote port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eGalvanic isolation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e200 VDC between input, output and case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-20 to +55 °C (derate 3 % per °C above 40 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eHumidity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eMax. 95 % non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDC connection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum cable cross-section\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e16 mm2 AWG6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e1.8 kg (4 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions hxwxd\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e130 x 186 x 80 mm (5.1 x 7.3 x 3.2 inch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards: Safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 60950\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEmission\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-3, EN 55014-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eImmunity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-2, EN 61000-6-1, EN 55014-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eAutomotive Directive\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eECE R10-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364389089563,"sku":"VIC-ORI122441110","price":269.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/VIC-ORI122441110-01.jpg?v=1781658163"},{"product_id":"victron-orion-tr-12v-to-24v-5a-isolated-dc-dc-converter","title":"Victron Energy - 12V to 24V - Orion-Tr - 12\/24-5A - Isolated DC-DC Converter","description":"\u003ch2\u003eVictron Orion-Tr 12\/24-5A Isolated DC-DC Converter: Clean, Stable Power for Sensitive Electronics\u003c\/h2\u003e\n\u003ch3\u003eGalvanic Isolation for Superior Noise Rejection and System Protection\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eVictron Orion-Tr 12\/24-5A\u003c\/strong\u003e delivers a regulated, isolated DC output, making it the ideal solution for powering sensitive loads where electrical noise and ground loops cannot be tolerated. Unlike non-isolated converters, this unit provides \u003cstrong\u003e200V DC galvanic isolation\u003c\/strong\u003e between input, output, and case, effectively breaking ground loops and suppressing interference. This is critical for \u003cstrong\u003emarine electronics\u003c\/strong\u003e, \u003cstrong\u003ecommunications equipment\u003c\/strong\u003e, and \u003cstrong\u003eindustrial sensors\u003c\/strong\u003e where signal integrity is paramount.\u003c\/p\u003e\n\u003cp\u003eWith a wide input voltage range of 8-17V, it maintains a stable output even when the source voltage fluctuates, protecting your equipment from brownouts and surges. The output voltage is fully adjustable from 20-30V, allowing precise matching to your load requirements.\u003c\/p\u003e\n\u003ch3\u003eEngineered for Demanding Environments\u003c\/h3\u003e\n\u003cp\u003eBuilt on Victron's proven Orion platform, this converter features a rugged, compact design with an \u003cstrong\u003eIP43 protection rating\u003c\/strong\u003e when installed with terminals facing downwards. Mounted in a dry, protected location (humidity max. 95% non-condensing), it suits \u003cstrong\u003eoff-grid solar systems\u003c\/strong\u003e, \u003cstrong\u003evehicle-based installations\u003c\/strong\u003e and \u003cstrong\u003eboats\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003ePassive cooling via an integrated aluminium heatsink eliminates noisy fans and moving parts, reducing maintenance and points of failure. The wide operating temperature range of -20 to +55°C (derating above 40°C) ensures consistent performance across Australia's diverse climates, from the tropical north to the arid interior.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic isolation (200V DC)\u003c\/strong\u003e between input, output, and case eliminates ground loops and protects sensitive electronics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide input voltage range\u003c\/strong\u003e (8-17V) with under-voltage shutdown and restart for battery protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable output voltage\u003c\/strong\u003e (20-30V) for precise load matching\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote on\/off control\u003c\/strong\u003e via low-power switch eliminates need for high-current input wiring switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort circuit proof\u003c\/strong\u003e and capable of unlimited parallel connection for higher current demands\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh efficiency\u003c\/strong\u003e up to 88% reduces heat generation and wasted energy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP43 protection\u003c\/strong\u003e when installed with terminals downwards, for a dry, protected mounting location\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact and lightweight\u003c\/strong\u003e design with integrated heatsink for fanless operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScrew terminals\u003c\/strong\u003e accept cables up to 6 mm² for secure, low-resistance connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications Where Clean Power Matters\u003c\/h3\u003e\n\u003cp\u003eThis isolated DC-DC converter excels in scenarios where voltage stability and noise immunity are non-negotiable:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine electronics:\u003c\/strong\u003e Power navigation systems, autopilots, and communication radios without interference from engine alternators or inverters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCaravans and RVs:\u003c\/strong\u003e Provide stable 24V to sensitive appliances like compressor fridges, LED lighting, and entertainment systems, regardless of battery voltage sag.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-grid solar systems:\u003c\/strong\u003e Step voltage up from 12V to 24V between battery banks of different voltages, or supply clean power to monitoring and control equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial and laboratory equipment:\u003c\/strong\u003e Isolate sensitive measurement instruments from noisy DC bus voltages in factories or test benches.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTelecommunications:\u003c\/strong\u003e Ensure reliable operation of remote radio repeaters and networking gear with a regulated, isolated supply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Choose an Isolated Converter?\u003c\/h3\u003e\n\u003cp\u003eStandard non-isolated DC-DC converters share a common ground between input and output, which can introduce electrical noise, ground loops, and potential damage to sensitive electronics. The Victron Orion-Tr isolated series breaks this connection, providing a 'floating' output that is electrically independent. This is especially important in vehicles and boats where multiple charging sources and varying ground potentials can cause erratic behaviour in connected devices.\u003c\/p\u003e\n\u003cp\u003eAdditionally, the adjustable output voltage allows this converter to be used as a \u003cstrong\u003econstant voltage power supply\u003c\/strong\u003e for equipment that requires a specific voltage, such as LED lighting systems or certain telecommunications gear. Note: This unit is a DC-DC converter, not a multi-stage battery charger. For battery charging applications, see the Victron Orion-Tr Smart Charger range.\u003c\/p\u003e\n\u003ch3\u003eInstallation and Integration\u003c\/h3\u003e\n\u003cp\u003eInstallation is straightforward with clearly labelled screw terminals and a removable green remote on\/off connector. The remote port can be wired to a vehicle's ignition switch, a manual toggle, or a BMS control signal, allowing automated power management. The compact footprint and multiple mounting points make it easy to fit into existing electrical enclosures or tight spaces.\u003c\/p\u003e\n\u003cp\u003eFor higher power requirements, multiple units can be connected in parallel with no practical limit, providing a scalable solution that grows with your system.\u003c\/p\u003e\n\u003ch3\u003ePower Your Critical Systems with Confidence\u003c\/h3\u003e\n\u003cp\u003eWhen clean, stable DC power is essential, trust the \u003cstrong\u003eVictron Orion-Tr 12\/24-5A\u003c\/strong\u003e to deliver. Whether you're outfitting a bluewater yacht, a remote off-grid cabin, or a mobile command vehicle, this isolated converter provides the reliability and performance that professionals demand. Add it to your power system today and eliminate electrical noise for good.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eInput voltage range (1)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e8-17 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage shut down\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e7 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage restart\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e7.5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNominal output voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e24.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage adjust range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e20-30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage tolerance\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e+\/- 0.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput noise\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e2 mV rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output current at nominal output voltage and 25 °C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum output current (10 s) at nominal output voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e6.3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eShort circuit output current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e23 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output power at 25 °C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e120 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output power at 40 °C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e110 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEfficiency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e88 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNo load input current (2)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 80 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCurrent consumption\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 200 uA when disabled via remote port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eGalvanic isolation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e200 V dc between input, output and case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-20 to +55 °C (derate 3 % per °C above 40 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eHumidity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eMax. 95 % non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDC connection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum cable cross-section\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e6 mm² AWG10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e0.42 kg (1 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions h x w x d\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e100 x 113 x 47 mm (4.0 x 4.5 x 1.9 inch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards: Safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 60950\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEmission\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-3, EN 55014-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eImmunity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-2, EN 61000-6-1, EN 55014-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eAutomotive Directive\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eECE R10-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364389220635,"sku":"Vic-ORI122410110","price":83.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/Vic-ORI122410110-01.jpg?v=1781658178"},{"product_id":"victron-orion-tr-12v-to-48v-8a-isolated-dc-dc-converter","title":"Victron Energy - 12V to 48V - Orion-Tr - 12\/48-8A - Isolated DC-DC Converter","description":"\u003ch2\u003eVictron Orion-Tr 12\/48-8 (380W) Isolated DC-DC Converter: Clean, Stable Power for Sensitive Electronics\u003c\/h2\u003e\n\u003ch3\u003eGalvanic Isolation for Superior Noise Rejection and System Protection\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eVictron Orion-Tr 12\/48-8 (380W)\u003c\/strong\u003e delivers a regulated, isolated DC output, making it the ideal solution for powering sensitive loads where electrical noise and ground loops cannot be tolerated. Unlike non-isolated converters, this unit provides \u003cstrong\u003e200V DC galvanic isolation\u003c\/strong\u003e between input, output, and case, effectively breaking ground loops and suppressing interference. This is critical for \u003cstrong\u003emarine electronics\u003c\/strong\u003e, \u003cstrong\u003ecommunications equipment\u003c\/strong\u003e, and \u003cstrong\u003eindustrial sensors\u003c\/strong\u003e where signal integrity is paramount.\u003c\/p\u003e\n\u003cp\u003eWith a wide input voltage range of 10-17V, it maintains a stable output even when the source voltage fluctuates, protecting your equipment from brownouts and surges. The output voltage is fully adjustable from 40-60V, allowing precise matching to your load requirements.\u003c\/p\u003e\n\u003ch3\u003eEngineered for Demanding Environments\u003c\/h3\u003e\n\u003cp\u003eBuilt on Victron's proven Orion platform, this converter features a rugged, compact design with an \u003cstrong\u003eIP43 protection rating\u003c\/strong\u003e when installed with terminals facing downwards. The fully potted electronics and conformal-coated PCB resist moisture, dust, and vibration, ensuring long-term reliability in \u003cstrong\u003eoff-grid solar systems\u003c\/strong\u003e, \u003cstrong\u003evehicle-based installations\u003c\/strong\u003e, and \u003cstrong\u003emarine engine rooms\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003ePassive cooling via an integrated aluminium heatsink eliminates noisy fans and moving parts, reducing maintenance and points of failure. The wide operating temperature range of -20 to +55°C (derating above 40°C) ensures consistent performance across Australia's diverse climates, from the tropical north to the arid interior.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic isolation (200V DC)\u003c\/strong\u003e between input, output, and case eliminates ground loops and protects sensitive electronics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide input voltage range\u003c\/strong\u003e (10-17V) with under-voltage shutdown and restart for battery protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable output voltage\u003c\/strong\u003e (40-60V) for precise load matching\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote on\/off control\u003c\/strong\u003e via low-power switch eliminates need for high-current input wiring switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort circuit proof\u003c\/strong\u003e and capable of unlimited parallel connection for higher current demands\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh efficiency\u003c\/strong\u003e up to 89% reduces heat generation and wasted energy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP43 protection\u003c\/strong\u003e when installed with terminals downwards, suitable for harsh environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact and lightweight\u003c\/strong\u003e design with integrated heatsink for fanless operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScrew terminals\u003c\/strong\u003e accept cables up to 16 mm² (AWG6) for secure, low-resistance connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications Where Clean Power Matters\u003c\/h3\u003e\n\u003cp\u003eThis isolated DC-DC converter excels in scenarios where voltage stability and noise immunity are non-negotiable:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine electronics:\u003c\/strong\u003e Power navigation systems, autopilots, and communication radios without interference from engine alternators or inverters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCaravans and RVs:\u003c\/strong\u003e Provide stable 48V to sensitive appliances like compressor fridges, LED lighting, and entertainment systems, regardless of battery voltage sag.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-grid solar systems:\u003c\/strong\u003e Step voltage up between battery banks of different voltages, or supply clean power to monitoring and control equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial and laboratory equipment:\u003c\/strong\u003e Isolate sensitive measurement instruments from noisy DC bus voltages in factories or test benches.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTelecommunications:\u003c\/strong\u003e Ensure reliable operation of remote radio repeaters and networking gear with a regulated, isolated supply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Choose an Isolated Converter?\u003c\/h3\u003e\n\u003cp\u003eStandard non-isolated DC-DC converters share a common ground between input and output, which can introduce electrical noise, ground loops, and potential damage to sensitive electronics. The Victron Orion-Tr isolated series breaks this connection, providing a 'floating' output that is electrically independent. This is especially important in vehicles and boats where multiple charging sources and varying ground potentials can cause erratic behaviour in connected devices.\u003c\/p\u003e\n\u003cp\u003eAdditionally, the adjustable output voltage allows this converter to be used as a \u003cstrong\u003econstant voltage power supply\u003c\/strong\u003e for equipment that requires a specific voltage, such as LED lighting systems or certain telecommunications gear. Note: This unit is a DC-DC converter, not a multi-stage battery charger. For battery charging applications, see the Victron Orion-Tr Smart Charger range.\u003c\/p\u003e\n\u003ch3\u003eInstallation and Integration\u003c\/h3\u003e\n\u003cp\u003eInstallation is straightforward with clearly labelled screw terminals and a removable green remote on\/off connector. The remote port can be wired to a vehicle's ignition switch, a manual toggle, or a BMS control signal, allowing automated power management. The compact footprint and multiple mounting points make it easy to fit into existing electrical enclosures or tight spaces.\u003c\/p\u003e\n\u003cp\u003eFor higher power requirements, multiple units can be connected in parallel with no practical limit, providing a scalable solution that grows with your system.\u003c\/p\u003e\n\u003ch3\u003ePower Your Critical Systems with Confidence\u003c\/h3\u003e\n\u003cp\u003eWhen clean, stable DC power is essential, trust the \u003cstrong\u003eVictron Orion-Tr 12\/48-8 (380W)\u003c\/strong\u003e to deliver. Whether you're outfitting a bluewater yacht, a remote off-grid cabin, or a mobile command vehicle, this isolated converter provides the reliability and performance that professionals demand. Add it to your power system today and eliminate electrical noise for good.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eOrion-Tr 12\/48-8 (380 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eInput voltage range (1)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e10-17 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage shut down\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e7 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage restart\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e7.5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNominal output voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e48.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage adjust range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e40-60 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage tolerance\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e+\/- 0.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput noise\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e2 mV rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output current at nominal output voltage and 40°C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e8A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum output current (10 s) at nominal output voltage minus 20%\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eShort circuit output current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output power at 25°C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e430 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output power at 40°C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e380 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEfficiency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e89%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNo load input current (2)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 220 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCurrent consumption\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 200uA when disabled via its remote port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eGalvanic isolation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e200 VDC between input, output and case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-20 to +55 °C (derate 3 % per °C above 40 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eHumidity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eMax. 95 % non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDC connection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum cable cross-section\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e16 mm2 AWG6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e1.8 kg (4 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions hxwxd\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e130 x 186 x 80 mm (5.1 x 7.3 x 3.2 inch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards: Safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 60950\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEmission\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-3, EN 55014-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eImmunity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-2, EN 61000-6-1, EN 55014-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eAutomotive Directive\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eECE R10-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364389318939,"sku":"VIC-ORI124838110","price":259.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/VIC-ORI124838110-01.jpg?v=1781658164"},{"product_id":"victron-orion-tr-24v-12v-9a-isolated-dc-dc-converter","title":"Victron Energy - 24V to 12V - Orion-Tr - 24\/12-9A - Isolated DC-DC Converter","description":"\u003ch2\u003eVictron Orion-Tr 24\/12-9A Isolated DC-DC Converter: Clean, Stable Power for Sensitive Electronics\u003c\/h2\u003e\n\u003ch3\u003eGalvanic Isolation for Superior Noise Rejection and System Protection\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eVictron Orion-Tr 24\/12-9A\u003c\/strong\u003e delivers a regulated, isolated DC output, making it the ideal solution for powering sensitive loads where electrical noise and ground loops cannot be tolerated. Unlike non-isolated converters, this unit provides \u003cstrong\u003e200V DC galvanic isolation\u003c\/strong\u003e between input, output, and case, effectively breaking ground loops and suppressing interference. This is critical for \u003cstrong\u003emarine electronics\u003c\/strong\u003e, \u003cstrong\u003ecommunications equipment\u003c\/strong\u003e, and \u003cstrong\u003eindustrial sensors\u003c\/strong\u003e where signal integrity is paramount.\u003c\/p\u003e\n\u003cp\u003eWith a wide input voltage range of 16-35V, it maintains a stable output even when the source voltage fluctuates, protecting your equipment from brownouts and surges. The output voltage is fully adjustable from 10-15V, allowing precise matching to your load requirements.\u003c\/p\u003e\n\u003ch3\u003eEngineered for Demanding Environments\u003c\/h3\u003e\n\u003cp\u003eBuilt on Victron's proven Orion platform, this converter features a rugged, compact design with an \u003cstrong\u003eIP43 protection rating\u003c\/strong\u003e when installed with terminals facing downwards. Mounted in a dry, protected location (humidity max. 95% non-condensing), it suits \u003cstrong\u003eoff-grid solar systems\u003c\/strong\u003e, \u003cstrong\u003evehicle-based installations\u003c\/strong\u003e and \u003cstrong\u003eboats\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003ePassive cooling via an integrated aluminium heatsink eliminates noisy fans and moving parts, reducing maintenance and points of failure. The wide operating temperature range of -20 to +55°C (derating above 40°C) ensures consistent performance across Australia's diverse climates, from the tropical north to the arid interior.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic isolation (200V DC)\u003c\/strong\u003e between input, output, and case eliminates ground loops and protects sensitive electronics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide input voltage range\u003c\/strong\u003e (16-35V) with under-voltage shutdown and restart for battery protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable output voltage\u003c\/strong\u003e (10-15V) for precise load matching\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote on\/off control\u003c\/strong\u003e via low-power switch eliminates need for high-current input wiring switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort circuit proof\u003c\/strong\u003e and capable of unlimited parallel connection for higher current demands\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh efficiency\u003c\/strong\u003e up to 85% reduces heat generation and wasted energy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP43 protection\u003c\/strong\u003e when installed with terminals downwards, for a dry, protected mounting location\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact and lightweight\u003c\/strong\u003e design with integrated heatsink for fanless operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScrew terminals\u003c\/strong\u003e accept cables up to 6 mm² AWG10 for secure, low-resistance connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications Where Clean Power Matters\u003c\/h3\u003e\n\u003cp\u003eThis isolated DC-DC converter excels in scenarios where voltage stability and noise immunity are non-negotiable:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine electronics:\u003c\/strong\u003e Power navigation systems, autopilots, and communication radios without interference from engine alternators or inverters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCaravans and RVs:\u003c\/strong\u003e Provide stable 12V to sensitive appliances like compressor fridges, LED lighting, and entertainment systems, regardless of battery voltage sag.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-grid solar systems:\u003c\/strong\u003e Step voltage down from 24V to 12V, or supply clean power to monitoring and control equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial and laboratory equipment:\u003c\/strong\u003e Isolate sensitive measurement instruments from noisy DC bus voltages in factories or test benches.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTelecommunications:\u003c\/strong\u003e Ensure reliable operation of remote radio repeaters and networking gear with a regulated, isolated supply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Choose an Isolated Converter?\u003c\/h3\u003e\n\u003cp\u003eStandard non-isolated DC-DC converters share a common ground between input and output, which can introduce electrical noise, ground loops, and potential damage to sensitive electronics. The Victron Orion-Tr isolated series breaks this connection, providing a 'floating' output that is electrically independent. This is especially important in vehicles and boats where multiple charging sources and varying ground potentials can cause erratic behaviour in connected devices.\u003c\/p\u003e\n\u003cp\u003eAdditionally, the adjustable output voltage allows this converter to be used as a \u003cstrong\u003econstant voltage power supply\u003c\/strong\u003e for equipment that requires a specific voltage, such as LED lighting systems or certain telecommunications gear. Note: This unit is a DC-DC converter, not a multi-stage battery charger. For battery charging applications, see the Victron Orion-Tr Smart Charger range.\u003c\/p\u003e\n\u003ch3\u003eInstallation and Integration\u003c\/h3\u003e\n\u003cp\u003eInstallation is straightforward with clearly labelled screw terminals and a removable green remote on\/off connector. The remote port can be wired to a vehicle's ignition switch, a manual toggle, or a BMS control signal, allowing automated power management. The compact footprint and multiple mounting points make it easy to fit into existing electrical enclosures or tight spaces.\u003c\/p\u003e\n\u003cp\u003eFor higher power requirements, multiple units can be connected in parallel with no practical limit, providing a scalable solution that grows with your system.\u003c\/p\u003e\n\u003ch3\u003ePower Your Critical Systems with Confidence\u003c\/h3\u003e\n\u003cp\u003eWhen clean, stable DC power is essential, trust the \u003cstrong\u003eVictron Orion-Tr 24\/12-9A\u003c\/strong\u003e to deliver. Whether you're outfitting a bluewater yacht, a remote off-grid cabin, or a mobile command vehicle, this isolated converter provides the reliability and performance that professionals demand. Add it to your power system today and eliminate electrical noise for good.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eInput voltage range (1)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e16-35 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage shut down\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e14 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage restart\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e15 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNominal output voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e12.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage adjust range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e10-15 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage tolerance\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e+\/- 0.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput noise\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e2 mV rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output current at nominal output voltage and 25 °C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum output current (10 s) at nominal output voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e12.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eShort circuit output current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e39 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output power at 25 °C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e110 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output power at 40 °C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e85 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEfficiency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e85 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNo load input current (2)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 40 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCurrent consumption\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 200 uA when disabled via remote port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eGalvanic isolation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e200 V dc between input, output and case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-20 to +55 °C (derate 3 % per °C above 40 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eHumidity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eMax. 95 % non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDC connection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum cable cross-section\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e6 mm² AWG10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e0.42 kg (1 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions h x w x d\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e100 x 113 x 47 mm (4.0 x 4.5 x 1.9 inch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards: Safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 60950\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEmission\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-3, EN 55014-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eImmunity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-2, EN 61000-6-1, EN 55014-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eAutomotive Directive\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eECE R10-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364389875995,"sku":"Vic-ORI241210110","price":88.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/Vic-ORI241210110-01.jpg?v=1781658177"},{"product_id":"victron-orion-tr-24v-to-12v-10a-120w-non-isolated-dc-dc-converter","title":"Victron Energy - 24V to 12V - Orion-Tr - 24\/12-10A - Non-Isolated DC-DC Converter","description":"\u003ch2\u003eReliable DC-DC Power Conversion for 12V Systems\u003c\/h2\u003e\n\u003cp\u003eIntegrate stable, efficient DC power into your vehicle or off-grid electrical system with the \u003cstrong\u003eVictron Orion-Tr 24\/12-10A Non-Isolated DC-DC converter\u003c\/strong\u003e. Designed for professional installations where voltage stability matters, it converts \u003cstrong\u003e18-35V to 12.5V\u003c\/strong\u003e to help protect sensitive loads and support consistent operation of devices such as \u003cstrong\u003ecommunications gear, LED lighting, fridges, navigation electronics\u003c\/strong\u003e and other DC equipment.\u003c\/p\u003e\n\u003cp\u003eIn real-world setups—especially in caravans, 4WDs, marine systems and remote power applications—DC supply can be unpredictable. Alternator output varies with engine speed, cable runs introduce voltage drop, and mixed-voltage battery banks can create compatibility issues. This unit helps reduce those risks by delivering a regulated output that better matches the needs of your downstream devices and distribution.\u003c\/p\u003e\n\u003ch2\u003eHigh Efficiency Where It Counts\u003c\/h2\u003e\n\u003cp\u003eVictron’s design approach prioritises conversion efficiency to minimise wasted energy and heat—an important advantage in enclosed electrical bays and compact builds. Higher efficiency can translate to \u003cstrong\u003eless strain on source batteries\u003c\/strong\u003e, improved runtime, and more headroom for additional loads. The design supports stable operation under changing input conditions, helping your system behave more predictably when the alternator, batteries or solar charging state changes.\u003c\/p\u003e\n\u003ch2\u003eInstallation-Ready for Mobile and Harsh Environments\u003c\/h2\u003e\n\u003cp\u003eBuilt for practical field installation, the unit features robust connections and a durable enclosure suited to mobile power systems. For applications where ventilation, dust and splash exposure are considerations, the housing and terminal layout are designed to support a tidy, serviceable install. Use it as part of a broader Victron ecosystem or as a focused solution to solve a specific voltage conversion requirement such as \u003cstrong\u003erunning 12V accessories from a 24V battery system\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eIdeal Use Cases Across Australia\u003c\/h2\u003e\n\u003cp\u003eFrom touring rigs to commercial fit-outs, DC-DC conversion is often the missing link between a source supply and reliable end-use power. This unit is a strong choice for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCaravan and RV electrics\u003c\/strong\u003e needing stable DC rails for accessories\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4WD touring\u003c\/strong\u003e where voltage drop and load spikes are common\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine systems\u003c\/strong\u003e requiring dependable DC power distribution\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-grid and industrial\u003c\/strong\u003e systems with mixed-voltage loads\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEfficient DC-DC conversion to support longer runtime and lower heat build-up\u003c\/li\u003e\n\u003cli\u003eRegulated output designed to improve stability for sensitive DC loads\u003c\/li\u003e\n\u003cli\u003eRugged construction suited to mobile, marine and off-grid environments\u003c\/li\u003e\n\u003cli\u003eInstaller-friendly terminals for secure cabling and straightforward servicing\u003c\/li\u003e\n\u003cli\u003eDesigned to integrate cleanly into professional power systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOptimised for Your System\u003c\/h2\u003e\n\u003cp\u003eThis version is specifically designed for \u003cstrong\u003e18-35V input\u003c\/strong\u003e, \u003cstrong\u003e12.5V output\u003c\/strong\u003e, and a \u003cstrong\u003e10A continuous output current requirement\u003c\/strong\u003e. If you’re planning a new build or upgrading an existing setup, this converter helps create a more predictable electrical system—reducing nuisance resets, improving device performance, and supporting cleaner power distribution.\u003c\/p\u003e\n\u003cp\u003eEquip your build with the \u003cstrong\u003eVictron Orion-Tr 24\/12-10A Non-Isolated DC-DC converter\u003c\/strong\u003e and power your \u003cstrong\u003e12V accessories from a 24V supply\u003c\/strong\u003e with stable, efficient DC conversion suited to Australian touring and off-grid conditions.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNon Isolated Converters\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eOrion-Tr 24\/12-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eInput Voltage Range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e18-35V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput Voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e12.5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEfficiency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eContinuous Output Current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e10A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMax. Output Current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e12A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eGalvanic Isolation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOff Load Current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt;45mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOperating Temperature Range (derate 3% per °C above 40°C)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-20 to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDC Connection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eScrew Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum Cable Cross-Section\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e6 mm² AWG10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight kg (lbs)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e0.2 (0.44)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions hxwxd in mm (hxwxd in inches)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e73x94x37 (2.9x3.7x1.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards Safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 60950\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards Emission\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-3, EN 55014-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards Immunity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-2, EN 61000-6-1, EN 55014-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards Automotive Directive\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eECE R10-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364390400283,"sku":"Vic-ORI241210200","price":46.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/Vic-ORI241210200-01.jpg?v=1781658177"},{"product_id":"victron-orion-tr-24v-to-12v-15a-180w-non-isolated-dc-dc-converter","title":"Victron Energy - 24V to 12V - Orion-Tr - 24\/12-15A - Non-Isolated DC-DC Converter","description":"\u003ch2\u003eReliable DC-DC Power Conversion for 24V to 12V Systems\u003c\/h2\u003e\n\u003cp\u003eIntegrate stable, efficient DC power into your vehicle or off-grid electrical system with the \u003cstrong\u003eVictron Orion-Tr 24\/12-15A Non-Isolated DC-DC converter\u003c\/strong\u003e. Designed for professional installations where voltage stability matters, it converts \u003cstrong\u003e24V (18-35V input range) to 12.5V\u003c\/strong\u003e to help protect sensitive loads and support consistent operation of devices such as \u003cstrong\u003ecommunications gear, LED lighting, fridges, navigation electronics\u003c\/strong\u003e and other DC equipment.\u003c\/p\u003e\n\u003cp\u003eIn real-world setups—especially in caravans, 4WDs, marine systems and remote power applications—DC supply can be unpredictable. Alternator output varies with engine speed, cable runs introduce voltage drop, and mixed-voltage battery banks can create compatibility issues. This unit helps reduce those risks by delivering a regulated output that better matches the needs of your downstream devices and distribution.\u003c\/p\u003e\n\u003ch2\u003eHigh Efficiency Where It Counts\u003c\/h2\u003e\n\u003cp\u003eVictron’s design approach prioritises conversion efficiency to minimise wasted energy and heat—an important advantage in enclosed electrical bays and compact builds. With a 97% efficiency rating, this unit translates to \u003cstrong\u003eless strain on source batteries\u003c\/strong\u003e, improved runtime, and more headroom for additional loads. The design supports stable operation under changing input conditions, helping your system behave more predictably when the alternator, batteries or solar charging state changes.\u003c\/p\u003e\n\u003ch2\u003eInstallation-Ready for Mobile and Harsh Environments\u003c\/h2\u003e\n\u003cp\u003eBuilt for practical field installation, the unit features robust connections and a durable enclosure suited to mobile power systems. For applications where ventilation, dust and splash exposure are considerations, the housing and terminal layout are designed to support a tidy, serviceable install. Use it as part of a broader Victron ecosystem or as a focused solution to solve a specific voltage conversion requirement such as \u003cstrong\u003erunning 12V electronics from a 24V battery system\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eIdeal Use Cases Across Australia\u003c\/h2\u003e\n\u003cp\u003eFrom touring rigs to commercial fit-outs, DC-DC conversion is often the missing link between a source supply and reliable end-use power. This unit is a strong choice for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCaravan and RV electrics\u003c\/strong\u003e needing stable DC rails for accessories\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4WD touring\u003c\/strong\u003e where voltage drop and load spikes are common\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine systems\u003c\/strong\u003e requiring dependable DC power distribution\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-grid and industrial\u003c\/strong\u003e systems with mixed-voltage loads\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEfficient DC-DC conversion to support longer runtime and lower heat build-up\u003c\/li\u003e\n\u003cli\u003eRegulated output designed to improve stability for sensitive DC loads\u003c\/li\u003e\n\u003cli\u003eRugged construction suited to mobile, marine and off-grid environments\u003c\/li\u003e\n\u003cli\u003eInstaller-friendly terminals for secure cabling and straightforward servicing\u003c\/li\u003e\n\u003cli\u003eDesigned to integrate cleanly into professional power systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOptimised for Your System\u003c\/h2\u003e\n\u003cp\u003eThis unit is matched for \u003cstrong\u003e24V (18-35V range) input\u003c\/strong\u003e, providing a regulated \u003cstrong\u003e12.5V output\u003c\/strong\u003e with a \u003cstrong\u003e15A continuous current capacity\u003c\/strong\u003e. If you’re planning a new build or upgrading an existing setup, this converter helps create a more predictable electrical system—reducing nuisance resets, improving device performance, and supporting cleaner power distribution.\u003c\/p\u003e\n\u003cp\u003eEquip your build with the \u003cstrong\u003eVictron Orion-Tr 24\/12-15A Non-Isolated DC-DC converter\u003c\/strong\u003e and power your \u003cstrong\u003e12V distribution from a 24V supply\u003c\/strong\u003e with stable, efficient DC conversion suited to Australian touring and off-grid conditions.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNon Isolated Converters\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eOrion-Tr 24\/12-15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eInput Voltage Range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e18-35V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput Voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e12.5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEfficiency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eContinuous Output Current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMax. Output Current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eGalvanic Isolation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOff Load Current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt;35mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOperating Temperature Range (derate 3% per °C above 40°C)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-20 to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDC Connection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eScrew Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum Cable Cross-Section\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e6 mm² AWG10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight kg (lbs)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e0.25 (0.55)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions hxwxd in mm (hxwxd in inches)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e73x94x45 (2.9x3.7x1.8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards Safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 60950\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards Emission\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-3, EN 55014-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards Immunity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-2, EN 61000-6-1, EN 55014-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards Automotive Directive\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eECE R10-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364390596891,"sku":"Vic-ORI241215200R","price":57.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/Vic-ORI241215200R-01.jpg?v=1781658177"},{"product_id":"victron-orion-tr-24v-to-12v-20a-240w-non-isolated-dc-dc-converter","title":"Victron Energy - 24V to 12V - Orion-Tr - 24\/12-20A - Non-Isolated DC-DC Converter","description":"\u003ch2\u003eReliable DC-DC Power Conversion for 24V to 12V Systems\u003c\/h2\u003e\n\u003cp\u003eIntegrate stable, efficient DC power into your vehicle or off-grid electrical system with the \u003cstrong\u003eVictron Orion-Tr 24\/12-20 DC-DC converter\u003c\/strong\u003e. Designed for professional installations where voltage stability matters, it converts \u003cstrong\u003e24V to 12V\u003c\/strong\u003e to help protect sensitive loads and support consistent operation of devices such as \u003cstrong\u003ecommunications gear, LED lighting, fridges, navigation electronics\u003c\/strong\u003e and other DC equipment.\u003c\/p\u003e\n\u003cp\u003eIn real-world setups—especially in caravans, 4WDs, marine systems and remote power applications—DC supply can be unpredictable. Alternator output varies with engine speed, cable runs introduce voltage drop, and mixed-voltage battery banks can create compatibility issues. This unit helps reduce those risks by delivering a regulated output that better matches the needs of your downstream devices and distribution.\u003c\/p\u003e\n\u003ch2\u003eHigh Efficiency Where It Counts\u003c\/h2\u003e\n\u003cp\u003eVictron’s design approach prioritises conversion efficiency to minimise wasted energy and heat—an important advantage in enclosed electrical bays and compact builds. With a 97% efficiency rating, this design supports stable operation under changing input conditions, helping your system behave more predictably when the alternator, batteries or solar charging state changes.\u003c\/p\u003e\n\u003ch2\u003eInstallation-Ready for Mobile and Harsh Environments\u003c\/h2\u003e\n\u003cp\u003eBuilt for practical field installation, the unit features robust connections and a durable enclosure suited to mobile power systems. For applications where ventilation, dust and splash exposure are considerations, the housing and terminal layout are designed to support a tidy, serviceable install. Use it as part of a broader Victron ecosystem or as a focused solution to solve a specific voltage conversion requirement such as \u003cstrong\u003epowering 12V electronics from a 24V battery bank\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eIdeal Use Cases Across Australia\u003c\/h2\u003e\n\u003cp\u003eFrom touring rigs to commercial fit-outs, DC-DC conversion is often the missing link between a source supply and reliable end-use power. This unit is a strong choice for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCaravan and RV electrics\u003c\/strong\u003e needing stable DC rails for accessories\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4WD touring\u003c\/strong\u003e where voltage drop and load spikes are common\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine systems\u003c\/strong\u003e requiring dependable DC power distribution\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-grid and industrial\u003c\/strong\u003e systems with mixed-voltage loads\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEfficient DC-DC conversion to support longer runtime and lower heat build-up\u003c\/li\u003e\n\u003cli\u003eRegulated output designed to improve stability for sensitive DC loads\u003c\/li\u003e\n\u003cli\u003eRugged construction suited to mobile, marine and off-grid environments\u003c\/li\u003e\n\u003cli\u003eInstaller-friendly terminals for secure cabling and straightforward servicing\u003c\/li\u003e\n\u003cli\u003eDesigned to integrate cleanly into professional power systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eThe Right Fit for Your System\u003c\/h2\u003e\n\u003cp\u003eThis unit is specifically designed for systems requiring a \u003cstrong\u003e24V\u003c\/strong\u003e input and a \u003cstrong\u003e12V\u003c\/strong\u003e output with a \u003cstrong\u003e20A (240W)\u003c\/strong\u003e capacity. If you’re planning a new build or upgrading an existing setup, this converter helps create a more predictable electrical system—reducing nuisance resets, improving device performance, and supporting cleaner power distribution.\u003c\/p\u003e\n\u003cp\u003eEquip your build with the \u003cstrong\u003eVictron Orion-Tr 24\/12-20\u003c\/strong\u003e and power your \u003cstrong\u003e12V accessories\u003c\/strong\u003e with stable, efficient DC conversion suited to Australian touring and off-grid conditions.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNon Isolated Converters\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eOrion-Tr 24\/12-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eInput Voltage Range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e18-35V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput Voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e12.5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEfficiency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eContinuous Output Current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMax. Output Current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e25A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eGalvanic Isolation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOff Load Current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt;35mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOperating Temperature Range (derate 3% per °C above 40°C)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-20 to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDC Connection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eScrew Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum Cable Cross-Section\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e6 mm² AWG10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight kg (lbs)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e0.25 (0.55)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions hxwxd in mm (hxwxd in inches)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e73x94x45 (2.9x3.7x1.8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards Safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 60950\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards Emission\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-3, EN 55014-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards Immunity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-2, EN 61000-6-1, EN 55014-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards Automotive Directive\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eECE R10-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364390891803,"sku":"Vic-ORI241220200","price":63.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/Vic-ORI241220200-01.jpg?v=1781658178"},{"product_id":"victron-orion-tr-24v-to-12v-20a-isolated-dc-dc-converter","title":"Victron Energy - 24V to 12V - Orion-Tr - 24\/12-20A - Isolated DC-DC Converter","description":"\u003ch2\u003eVictron Orion-Tr 24\/12-20 (240W) Isolated DC-DC Converter: Clean, Stable Power for Sensitive Electronics\u003c\/h2\u003e\n\u003ch3\u003eGalvanic Isolation for Superior Noise Rejection and System Protection\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eVictron Orion-Tr 24\/12-20 (240W)\u003c\/strong\u003e delivers a regulated, isolated DC output, making it the ideal solution for powering sensitive loads where electrical noise and ground loops cannot be tolerated. Unlike non-isolated converters, this unit provides \u003cstrong\u003e200V DC galvanic isolation\u003c\/strong\u003e between input, output, and case, effectively breaking ground loops and suppressing interference. This is critical for \u003cstrong\u003emarine electronics\u003c\/strong\u003e, \u003cstrong\u003ecommunications equipment\u003c\/strong\u003e, and \u003cstrong\u003eindustrial sensors\u003c\/strong\u003e where signal integrity is paramount.\u003c\/p\u003e\n\u003cp\u003eWith a wide input voltage range of 16-35V, it maintains a stable output even when the source voltage fluctuates, protecting your equipment from brownouts and surges. The output voltage is fully adjustable from 10-15V, allowing precise matching to your load requirements.\u003c\/p\u003e\n\u003ch3\u003eEngineered for Demanding Environments\u003c\/h3\u003e\n\u003cp\u003eBuilt on Victron's proven Orion platform, this converter features a rugged, compact design with an \u003cstrong\u003eIP43 protection rating\u003c\/strong\u003e when installed with terminals facing downwards. The fully potted electronics and conformal-coated PCB resist moisture, dust, and vibration, ensuring long-term reliability in \u003cstrong\u003eoff-grid solar systems\u003c\/strong\u003e, \u003cstrong\u003evehicle-based installations\u003c\/strong\u003e, and \u003cstrong\u003emarine engine rooms\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003ePassive cooling via an integrated aluminium heatsink eliminates noisy fans and moving parts, reducing maintenance and points of failure. The wide operating temperature range of -20 to +55°C (derating above 40°C) ensures consistent performance across Australia's diverse climates, from the tropical north to the arid interior.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic isolation (200V DC)\u003c\/strong\u003e between input, output, and case eliminates ground loops and protects sensitive electronics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide input voltage range\u003c\/strong\u003e (16-35V) with under-voltage shutdown and restart for battery protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable output voltage\u003c\/strong\u003e (10-15V) for precise load matching\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote on\/off control\u003c\/strong\u003e via low-power switch eliminates need for high-current input wiring switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort circuit proof\u003c\/strong\u003e and capable of unlimited parallel connection for higher current demands\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh efficiency\u003c\/strong\u003e up to 88% reduces heat generation and wasted energy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP43 protection\u003c\/strong\u003e when installed with terminals downwards, suitable for harsh environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact and lightweight\u003c\/strong\u003e design with integrated heatsink for fanless operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScrew terminals\u003c\/strong\u003e accept cables up to 16 mm² (AWG6) for secure, low-resistance connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications Where Clean Power Matters\u003c\/h3\u003e\n\u003cp\u003eThis isolated DC-DC converter excels in scenarios where voltage stability and noise immunity are non-negotiable:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine electronics:\u003c\/strong\u003e Power navigation systems, autopilots, and communication radios without interference from engine alternators or inverters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCaravans and RVs:\u003c\/strong\u003e Provide stable 12V to sensitive appliances like compressor fridges, LED lighting, and entertainment systems, regardless of battery voltage sag.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-grid solar systems:\u003c\/strong\u003e Step voltage down from 24V to 12V battery banks, or supply clean power to monitoring and control equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial and laboratory equipment:\u003c\/strong\u003e Isolate sensitive measurement instruments from noisy DC bus voltages in factories or test benches.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTelecommunications:\u003c\/strong\u003e Ensure reliable operation of remote radio repeaters and networking gear with a regulated, isolated supply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Choose an Isolated Converter?\u003c\/h3\u003e\n\u003cp\u003eStandard non-isolated DC-DC converters share a common ground between input and output, which can introduce electrical noise, ground loops, and potential damage to sensitive electronics. The Victron Orion-Tr isolated series breaks this connection, providing a 'floating' output that is electrically independent. This is especially important in vehicles and boats where multiple charging sources and varying ground potentials can cause erratic behaviour in connected devices.\u003c\/p\u003e\n\u003cp\u003eAdditionally, the adjustable output voltage allows this converter to be used as a \u003cstrong\u003econstant voltage power supply\u003c\/strong\u003e for equipment that requires a specific voltage, such as LED lighting systems or certain telecommunications gear. Note: This unit is a DC-DC converter, not a multi-stage battery charger. For battery charging applications, see the Victron Orion-Tr Smart Charger range.\u003c\/p\u003e\n\u003ch3\u003eInstallation and Integration\u003c\/h3\u003e\n\u003cp\u003eInstallation is straightforward with clearly labelled screw terminals and a removable green remote on\/off connector. The remote port can be wired to a vehicle's ignition switch, a manual toggle, or a BMS control signal, allowing automated power management. The compact footprint and multiple mounting points make it easy to fit into existing electrical enclosures or tight spaces.\u003c\/p\u003e\n\u003cp\u003eFor higher power requirements, multiple units can be connected in parallel with no practical limit, providing a scalable solution that grows with your system.\u003c\/p\u003e\n\u003ch3\u003ePower Your Critical Systems with Confidence\u003c\/h3\u003e\n\u003cp\u003eWhen clean, stable DC power is essential, trust the \u003cstrong\u003eVictron Orion-Tr 24\/12-20 (240W)\u003c\/strong\u003e to deliver. Whether you're outfitting a bluewater yacht, a remote off-grid cabin, or a mobile command vehicle, this isolated converter provides the reliability and performance that professionals demand. Add it to your power system today and eliminate electrical noise for good.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eOrion-Tr 24\/12-20 (240 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eInput voltage range (1)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e16-35 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage shut down\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e14 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage restart\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e15 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNominal output voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e12.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage adjust range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e10-15 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage tolerance\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e+\/- 0.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput noise\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e2 mV rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output current at nominal output voltage and 40 °C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum output current (10 s) at nominal output voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eShort circuit output current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output power at 25 °C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e300 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output power at 40 °C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e240 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEfficiency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e88%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNo load input current (2)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCurrent consumption\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 200uA when disabled via its remote port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eGalvanic isolation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e200 VDC between input, output and case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-20 to +55 °C (derate 3 % per °C above 40 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eHumidity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eMax. 95 % non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDC connection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum cable cross-section\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e16 mm2 AWG6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e1.3 kg (3 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions h x w x d\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e130 x 186 x 70 mm (5.1 x 7.3 x 2.8 inch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards: Safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 60950\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards: Emission\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-3, EN 55014-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards: Immunity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-2, EN 61000-6-1, EN 55014-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards: Automotive Directive\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eECE R10-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364391121179,"sku":"Vic-ORI241224110","price":154.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/Vic-ORI241224110-01.jpg?v=1781658353"},{"product_id":"victron-orion-tr-24v-to-12v-30a-isolated-dc-dc-converter","title":"Victron Energy - 24V to 12V - Orion-Tr - 24\/12-30A - Isolated DC-DC Converter","description":"\u003ch2\u003eVictron Orion-Tr 24\/12-30A Isolated DC-DC Converter: Clean, Stable Power for Sensitive Electronics\u003c\/h2\u003e\n\u003ch3\u003eGalvanic Isolation for Superior Noise Rejection and System Protection\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eVictron Orion-Tr 24\/12-30A\u003c\/strong\u003e delivers a regulated, isolated DC output, making it the ideal solution for powering sensitive loads where electrical noise and ground loops cannot be tolerated. Unlike non-isolated converters, this unit provides \u003cstrong\u003e200V DC galvanic isolation\u003c\/strong\u003e between input, output, and case, effectively breaking ground loops and suppressing interference. This is critical for \u003cstrong\u003emarine electronics\u003c\/strong\u003e, \u003cstrong\u003ecommunications equipment\u003c\/strong\u003e, and \u003cstrong\u003eindustrial sensors\u003c\/strong\u003e where signal integrity is paramount.\u003c\/p\u003e\n\u003cp\u003eWith a wide input voltage range of 20-35V, it maintains a stable output even when the source voltage fluctuates, protecting your equipment from brownouts and surges. The output voltage is fully adjustable from 10-15V, allowing precise matching to your load requirements.\u003c\/p\u003e\n\u003ch3\u003eEngineered for Demanding Environments\u003c\/h3\u003e\n\u003cp\u003eBuilt on Victron's proven Orion platform, this converter features a rugged, compact design with an \u003cstrong\u003eIP43 protection rating\u003c\/strong\u003e when installed with terminals facing downwards. Mounted in a dry, protected location (humidity max. 95% non-condensing), it suits \u003cstrong\u003eoff-grid solar systems\u003c\/strong\u003e, \u003cstrong\u003evehicle-based installations\u003c\/strong\u003e and \u003cstrong\u003eboats\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003ePassive cooling via an integrated aluminium heatsink eliminates noisy fans and moving parts, reducing maintenance and points of failure. The wide operating temperature range of -20 to +55°C (derating above 40°C) ensures consistent performance across Australia's diverse climates, from the tropical north to the arid interior.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic isolation (200V DC)\u003c\/strong\u003e between input, output, and case eliminates ground loops and protects sensitive electronics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide input voltage range\u003c\/strong\u003e (20-35V) with under-voltage shutdown and restart for battery protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable output voltage\u003c\/strong\u003e (10-15V) for precise load matching\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote on\/off control\u003c\/strong\u003e via low-power switch eliminates need for high-current input wiring switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort circuit proof\u003c\/strong\u003e and capable of unlimited parallel connection for higher current demands\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh efficiency\u003c\/strong\u003e up to 88% reduces heat generation and wasted energy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP43 protection\u003c\/strong\u003e when installed with terminals downwards, for a dry, protected mounting location\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact and lightweight\u003c\/strong\u003e design with integrated heatsink for fanless operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScrew terminals\u003c\/strong\u003e accept cables up to 16 mm² (AWG6) for secure, low-resistance connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications Where Clean Power Matters\u003c\/h3\u003e\n\u003cp\u003eThis isolated DC-DC converter excels in scenarios where voltage stability and noise immunity are non-negotiable:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine electronics:\u003c\/strong\u003e Power navigation systems, autopilots, and communication radios without interference from engine alternators or inverters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCaravans and RVs:\u003c\/strong\u003e Provide stable 12V to sensitive appliances like compressor fridges, LED lighting, and entertainment systems, regardless of battery voltage sag.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-grid solar systems:\u003c\/strong\u003e Step voltage down from 24V to 12V between battery banks of different voltages, or supply clean power to monitoring and control equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial and laboratory equipment:\u003c\/strong\u003e Isolate sensitive measurement instruments from noisy DC bus voltages in factories or test benches.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTelecommunications:\u003c\/strong\u003e Ensure reliable operation of remote radio repeaters and networking gear with a regulated, isolated supply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Choose an Isolated Converter?\u003c\/h3\u003e\n\u003cp\u003eStandard non-isolated DC-DC converters share a common ground between input and output, which can introduce electrical noise, ground loops, and potential damage to sensitive electronics. The Victron Orion-Tr isolated series breaks this connection, providing a 'floating' output that is electrically independent. This is especially important in vehicles and boats where multiple charging sources and varying ground potentials can cause erratic behaviour in connected devices.\u003c\/p\u003e\n\u003cp\u003eAdditionally, the adjustable output voltage allows this converter to be used as a \u003cstrong\u003econstant voltage power supply\u003c\/strong\u003e for equipment that requires a specific voltage, such as LED lighting systems or certain telecommunications gear. Note: This unit is a DC-DC converter, not a multi-stage battery charger. For battery charging applications, see the Victron Orion-Tr Smart Charger range.\u003c\/p\u003e\n\u003ch3\u003eInstallation and Integration\u003c\/h3\u003e\n\u003cp\u003eInstallation is straightforward with clearly labelled screw terminals and a removable green remote on\/off connector. The remote port can be wired to a vehicle's ignition switch, a manual toggle, or a BMS control signal, allowing automated power management. The compact footprint and multiple mounting points make it easy to fit into existing electrical enclosures or tight spaces.\u003c\/p\u003e\n\u003cp\u003eFor higher power requirements, multiple units can be connected in parallel with no practical limit, providing a scalable solution that grows with your system.\u003c\/p\u003e\n\u003ch3\u003ePower Your Critical Systems with Confidence\u003c\/h3\u003e\n\u003cp\u003eWhen clean, stable DC power is essential, trust the \u003cstrong\u003eVictron Orion-Tr 24\/12-30A\u003c\/strong\u003e to deliver. Whether you're outfitting a bluewater yacht, a remote off-grid cabin, or a mobile command vehicle, this isolated converter provides the reliability and performance that professionals demand. Add it to your power system today and eliminate electrical noise for good.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eOrion-Tr 24\/12-30 (360 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eInput voltage range (1)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e20-35 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage shut down\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e14 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage restart\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e15 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNominal output voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e12.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage adjust range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e10-15 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage tolerance\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e+\/- 0.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput noise\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e2 mV rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output current at nominal output voltage and 40°C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum output current (10 s) at nominal output voltage minus 20%\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e45 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eShort circuit output current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e60 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output power at 25°C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e430 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output power at 40°C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e360 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEfficiency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e88%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNo load input current (2)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCurrent consumption\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 200uA when disabled via its remote port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eGalvanic isolation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e200 VDC between input, output and case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-20 to +55 °C (derate 3 % per °C above 40 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eHumidity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eMax. 95 % non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDC connection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum cable cross-section\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e16 mm2 AWG6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e1.8 kg (4 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions hxwxd\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e130 x 186 x 80 mm (5.1 x 7.3 x 3.2 inch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards: Safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 60950\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEmission\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-3, EN 55014-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eImmunity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-2, EN 61000-6-1, EN 55014-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eAutomotive Directive\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eECE R10-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364391973147,"sku":"VIC-ORI241240110","price":269.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/VIC-ORI241240110-01.jpg?v=1781658355"},{"product_id":"victron-orion-tr-24v-to-12v-5a-60w-non-isolated-dc-dc-converter","title":"Victron Energy - 24V to 12V - Orion-Tr - 24\/12-5A - Non-Isolated DC-DC Converter","description":"\u003ch2\u003eReliable DC-DC Power Conversion for 24V Systems\u003c\/h2\u003e\n\u003cp\u003eIntegrate stable, efficient DC power into your vehicle or off-grid electrical system with the \u003cstrong\u003eVictron Orion-Tr 24\/12-5A Non-Isolated DC-DC converter\u003c\/strong\u003e. Designed for professional installations where voltage stability matters, it converts \u003cstrong\u003e24V DC (18–35V range) to 12.7V DC\u003c\/strong\u003e to help protect sensitive loads and support consistent operation of devices such as \u003cstrong\u003ecommunications gear, LED lighting, fridges, navigation electronics\u003c\/strong\u003e and other DC equipment.\u003c\/p\u003e\n\u003cp\u003eIn real-world setups—especially in caravans, 4WDs, marine systems and remote power applications—DC supply can be unpredictable. Alternator output varies with engine speed, cable runs introduce voltage drop, and mixed-voltage battery banks can create compatibility issues. This unit helps reduce those risks by delivering a regulated output that better matches the needs of your downstream devices and distribution.\u003c\/p\u003e\n\u003ch2\u003eHigh Efficiency Where It Counts\u003c\/h2\u003e\n\u003cp\u003eVictron’s design approach prioritises conversion efficiency to minimise wasted energy and heat—an important advantage in enclosed electrical bays and compact builds. Higher efficiency can translate to \u003cstrong\u003eless strain on source batteries\u003c\/strong\u003e, improved runtime, and more headroom for additional loads. The design supports stable operation under changing input conditions, helping your system behave more predictably when the alternator, batteries or solar charging state changes.\u003c\/p\u003e\n\u003ch2\u003eInstallation-Ready for Mobile and Harsh Environments\u003c\/h2\u003e\n\u003cp\u003eBuilt for practical field installation, the unit features robust connections and a durable enclosure suited to mobile power systems. For applications where ventilation, dust and splash exposure are considerations, the housing and terminal layout are designed to support a tidy, serviceable install. Use it as part of a broader Victron ecosystem or as a focused solution to solve a specific voltage conversion requirement such as \u003cstrong\u003erunning 12V accessories from a 24V battery system\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eIdeal Use Cases Across Australia\u003c\/h2\u003e\n\u003cp\u003eFrom touring rigs to commercial fit-outs, DC-DC conversion is often the missing link between a source supply and reliable end-use power. This unit is a strong choice for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCaravan and RV electrics\u003c\/strong\u003e needing stable DC rails for accessories\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4WD touring\u003c\/strong\u003e where voltage drop and load spikes are common\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine systems\u003c\/strong\u003e requiring dependable DC power distribution\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-grid and industrial\u003c\/strong\u003e systems with mixed-voltage loads\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEfficient DC-DC conversion to support longer runtime and lower heat build-up\u003c\/li\u003e\n\u003cli\u003eRegulated output designed to improve stability for sensitive DC loads\u003c\/li\u003e\n\u003cli\u003eRugged construction suited to mobile, marine and off-grid environments\u003c\/li\u003e\n\u003cli\u003eInstaller-friendly screw terminals for secure cabling and straightforward servicing\u003c\/li\u003e\n\u003cli\u003eDesigned to integrate cleanly into professional power systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOptimised for Your Power Requirements\u003c\/h2\u003e\n\u003cp\u003eThis model is specifically designed for systems requiring \u003cstrong\u003e24V DC (18–35V range)\u003c\/strong\u003e input, a \u003cstrong\u003e12.7V DC\u003c\/strong\u003e output, and \u003cstrong\u003e5A continuous output (up to 7A max)\u003c\/strong\u003e. If you’re planning a new build or upgrading an existing setup, this converter helps create a more predictable electrical system—reducing nuisance resets, improving device performance, and supporting cleaner power distribution.\u003c\/p\u003e\n\u003cp\u003eEquip your build with the \u003cstrong\u003eVictron Orion-Tr 24\/12-5A Non-Isolated DC-DC converter\u003c\/strong\u003e and power your \u003cstrong\u003e12V accessories from a 24V battery system\u003c\/strong\u003e with stable, efficient DC conversion suited to Australian touring and off-grid conditions.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNon Isolated Converters\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eOrion-Tr 24\/12-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eInput Voltage Range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e18-35V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput Voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e12.7V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEfficiency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eContinuous Output Current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMax. Output Current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e7A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eGalvanic Isolation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOff Load Current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt;20mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOperating Temperature Range (derate 3% per °C above 40°C)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-20 to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDC Connection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eScrew Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum Cable Cross-Section\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e3.3 mm² AWG12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight kg (lbs)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e0.09 (0.20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions hxwxd in mm (hxwxd in inches)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e53x51x27 (2.1x2x1.1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards Safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 60950\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards Emission\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-3, EN 55014-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards Immunity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-2, EN 61000-6-1, EN 55014-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards Automotive Directive\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eECE R10-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364392333595,"sku":"Vic-ORI241205200","price":23.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/Vic-ORI241205200-01.jpg?v=1781658169"},{"product_id":"victron-orion-tr-24v-to-24v-12a-isolated-dc-dc-converter","title":"Victron Energy - 24V to 24V - Orion-Tr - 24\/24-12A - Isolated DC-DC Converter","description":"\u003ch2\u003eVictron Orion-Tr 24\/24-12A Isolated DC-DC Converter: Clean, Stable Power for Sensitive Electronics\u003c\/h2\u003e\n\u003ch3\u003eGalvanic Isolation for Superior Noise Rejection and System Protection\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eVictron Orion-Tr 24\/24-12A\u003c\/strong\u003e delivers a regulated, isolated DC output, making it the ideal solution for powering sensitive loads where electrical noise and ground loops cannot be tolerated. Unlike non-isolated converters, this unit provides \u003cstrong\u003e200V DC galvanic isolation\u003c\/strong\u003e between input, output, and case, effectively breaking ground loops and suppressing interference. This is critical for \u003cstrong\u003emarine electronics\u003c\/strong\u003e, \u003cstrong\u003ecommunications equipment\u003c\/strong\u003e, and \u003cstrong\u003eindustrial sensors\u003c\/strong\u003e where signal integrity is paramount.\u003c\/p\u003e\n\u003cp\u003eWith a wide input voltage range of 16-35V, it maintains a stable output even when the source voltage fluctuates, protecting your equipment from brownouts and surges. The output voltage is fully adjustable from 20-30V, allowing precise matching to your load requirements.\u003c\/p\u003e\n\u003ch3\u003eEngineered for Demanding Environments\u003c\/h3\u003e\n\u003cp\u003eBuilt on Victron's proven Orion platform, this converter features a rugged, compact design with an \u003cstrong\u003eIP43 protection rating\u003c\/strong\u003e when installed with terminals facing downwards. Mounted in a dry, protected location (humidity max. 95% non-condensing), it suits \u003cstrong\u003eoff-grid solar systems\u003c\/strong\u003e, \u003cstrong\u003evehicle-based installations\u003c\/strong\u003e and \u003cstrong\u003eboats\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003ePassive cooling via an integrated aluminium heatsink eliminates noisy fans and moving parts, reducing maintenance and points of failure. The wide operating temperature range of -20 to +55°C (derating above 40°C) ensures consistent performance across Australia's diverse climates, from the tropical north to the arid interior.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic isolation (200V DC)\u003c\/strong\u003e between input, output, and case eliminates ground loops and protects sensitive electronics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide input voltage range\u003c\/strong\u003e (16-35V) with under-voltage shutdown and restart for battery protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable output voltage\u003c\/strong\u003e (20-30V) for precise load matching\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote on\/off control\u003c\/strong\u003e via low-power switch eliminates need for high-current input wiring switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort circuit proof\u003c\/strong\u003e and capable of unlimited parallel connection for higher current demands\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh efficiency\u003c\/strong\u003e up to 89% reduces heat generation and wasted energy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP43 protection\u003c\/strong\u003e when installed with terminals downwards, for a dry, protected mounting location\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact and lightweight\u003c\/strong\u003e design with integrated heatsink for fanless operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScrew terminals\u003c\/strong\u003e accept cables up to 16 mm² (AWG6) for secure, low-resistance connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications Where Clean Power Matters\u003c\/h3\u003e\n\u003cp\u003eThis isolated DC-DC converter excels in scenarios where voltage stability and noise immunity are non-negotiable:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine electronics:\u003c\/strong\u003e Power navigation systems, autopilots, and communication radios without interference from engine alternators or inverters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCaravans and RVs:\u003c\/strong\u003e Provide stable 24V to sensitive appliances like compressor fridges, LED lighting, and entertainment systems, regardless of battery voltage sag.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-grid solar systems:\u003c\/strong\u003e Supply clean, isolated power to monitoring and control equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial and laboratory equipment:\u003c\/strong\u003e Isolate sensitive measurement instruments from noisy DC bus voltages in factories or test benches.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTelecommunications:\u003c\/strong\u003e Ensure reliable operation of remote radio repeaters and networking gear with a regulated, isolated supply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Choose an Isolated Converter?\u003c\/h3\u003e\n\u003cp\u003eStandard non-isolated DC-DC converters share a common ground between input and output, which can introduce electrical noise, ground loops, and potential damage to sensitive electronics. The Victron Orion-Tr isolated series breaks this connection, providing a 'floating' output that is electrically independent. This is especially important in vehicles and boats where multiple charging sources and varying ground potentials can cause erratic behaviour in connected devices.\u003c\/p\u003e\n\u003cp\u003eAdditionally, the adjustable output voltage allows this converter to be used as a \u003cstrong\u003econstant voltage power supply\u003c\/strong\u003e for equipment that requires a specific voltage, such as LED lighting systems or certain telecommunications gear. Note: This unit is a DC-DC converter, not a multi-stage battery charger. For battery charging applications, see the Victron Orion-Tr Smart Charger range.\u003c\/p\u003e\n\u003ch3\u003eInstallation and Integration\u003c\/h3\u003e\n\u003cp\u003eInstallation is straightforward with clearly labelled screw terminals and a removable green remote on\/off connector. The remote port can be wired to a vehicle's ignition switch, a manual toggle, or a BMS control signal, allowing automated power management. The compact footprint and multiple mounting points make it easy to fit into existing electrical enclosures or tight spaces.\u003c\/p\u003e\n\u003cp\u003eFor higher power requirements, multiple units can be connected in parallel with no practical limit, providing a scalable solution that grows with your system.\u003c\/p\u003e\n\u003ch3\u003ePower Your Critical Systems with Confidence\u003c\/h3\u003e\n\u003cp\u003eWhen clean, stable DC power is essential, trust the \u003cstrong\u003eVictron Orion-Tr 24\/24-12A\u003c\/strong\u003e to deliver. Whether you're outfitting a bluewater yacht, a remote off-grid cabin, or a mobile command vehicle, this isolated converter provides the reliability and performance that professionals demand. Add it to your power system today and eliminate electrical noise for good.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eOrion-Tr 24\/24-12 (280 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eInput voltage range (1)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e16-35 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage shut down\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e14 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage restart\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e15 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNominal output voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e24.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage adjust range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e20-30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage tolerance\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e+\/- 0.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput noise\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e2 mV rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output current at nominal output voltage and 40 °C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e12A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum output current (10 s) at nominal output voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eShort circuit output current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output power at 25 °C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e320 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output power at 40 °C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e280 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEfficiency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e89%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNo load input current (2)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 80 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCurrent consumption\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 200uA when disabled via its remote port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eGalvanic isolation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e200 VDC between input, output and case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-20 to +55 °C (derate 3 % per °C above 40 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eHumidity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eMax. 95 % non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDC connection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum cable cross-section\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e16 mm2 AWG6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e1.3 kg (3 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions h x w x d\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e130 x 186 x 70 mm (5.1 x 7.3 x 2.8 inch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards: Safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 60950\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards: Emission\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-3, EN 55014-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards: Immunity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-2, EN 61000-6-1, EN 55014-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards: Automotive Directive\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eECE R10-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364392464667,"sku":"Vic-ORI242428110","price":149.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/Vic-ORI242428110-01.jpg?v=1781658360"},{"product_id":"victron-orion-tr-24v-to-24v-17a-isolated-dc-dc-converter","title":"Victron Energy - 24V to 24V - Orion-Tr - 24\/24-17A - Isolated DC-DC Converter","description":"\u003ch2\u003eVictron Orion-Tr 24\/24-17 Isolated DC-DC Converter: Clean, Stable Power for Sensitive Electronics\u003c\/h2\u003e\n\u003ch3\u003eGalvanic Isolation for Superior Noise Rejection and System Protection\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eVictron Orion-Tr 24\/24-17\u003c\/strong\u003e delivers a regulated, isolated DC output, making it the ideal solution for powering sensitive loads where electrical noise and ground loops cannot be tolerated. Unlike non-isolated converters, this unit provides \u003cstrong\u003e200V DC galvanic isolation\u003c\/strong\u003e between input, output, and case, effectively breaking ground loops and suppressing interference. This is critical for \u003cstrong\u003emarine electronics\u003c\/strong\u003e, \u003cstrong\u003ecommunications equipment\u003c\/strong\u003e, and \u003cstrong\u003eindustrial sensors\u003c\/strong\u003e where signal integrity is paramount.\u003c\/p\u003e\n\u003cp\u003eWith a wide input voltage range of 20-35V, it maintains a stable output even when the source voltage fluctuates, protecting your equipment from brownouts and surges. The output voltage is fully adjustable from 20-30V, allowing precise matching to your load requirements.\u003c\/p\u003e\n\u003ch3\u003eEngineered for Demanding Environments\u003c\/h3\u003e\n\u003cp\u003eBuilt on Victron's proven Orion platform, this converter features a rugged, compact design with an \u003cstrong\u003eIP43 protection rating\u003c\/strong\u003e when installed with terminals facing downwards. Mounted in a dry, protected location (humidity max. 95% non-condensing), it suits \u003cstrong\u003eoff-grid solar systems\u003c\/strong\u003e, \u003cstrong\u003evehicle-based installations\u003c\/strong\u003e and \u003cstrong\u003eboats\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003ePassive cooling via an integrated aluminium heatsink eliminates noisy fans and moving parts, reducing maintenance and points of failure. The wide operating temperature range of -20 to +55°C (derating above 40°C) ensures consistent performance across Australia's diverse climates, from the tropical north to the arid interior.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic isolation (200V DC)\u003c\/strong\u003e between input, output, and case eliminates ground loops and protects sensitive electronics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide input voltage range\u003c\/strong\u003e (20-35V) with under-voltage shutdown and restart for battery protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable output voltage\u003c\/strong\u003e (20-30V) for precise load matching\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote on\/off control\u003c\/strong\u003e via low-power switch eliminates need for high-current input wiring switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort circuit proof\u003c\/strong\u003e and capable of unlimited parallel connection for higher current demands\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh efficiency\u003c\/strong\u003e up to 89% reduces heat generation and wasted energy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP43 protection\u003c\/strong\u003e when installed with terminals downwards, for a dry, protected mounting location\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact and lightweight\u003c\/strong\u003e design with integrated heatsink for fanless operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScrew terminals\u003c\/strong\u003e accept cables up to 16 mm² (AWG6) for secure, low-resistance connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications Where Clean Power Matters\u003c\/h3\u003e\n\u003cp\u003eThis isolated DC-DC converter excels in scenarios where voltage stability and noise immunity are non-negotiable:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine electronics:\u003c\/strong\u003e Power navigation systems, autopilots, and communication radios without interference from engine alternators or inverters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCaravans and RVs:\u003c\/strong\u003e Provide stable 24V to sensitive appliances like compressor fridges, LED lighting, and entertainment systems, regardless of battery voltage sag.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-grid solar systems:\u003c\/strong\u003e Supply clean, isolated power to monitoring and control equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial and laboratory equipment:\u003c\/strong\u003e Isolate sensitive measurement instruments from noisy DC bus voltages in factories or test benches.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTelecommunications:\u003c\/strong\u003e Ensure reliable operation of remote radio repeaters and networking gear with a regulated, isolated supply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Choose an Isolated Converter?\u003c\/h3\u003e\n\u003cp\u003eStandard non-isolated DC-DC converters share a common ground between input and output, which can introduce electrical noise, ground loops, and potential damage to sensitive electronics. The Victron Orion-Tr isolated series breaks this connection, providing a 'floating' output that is electrically independent. This is especially important in vehicles and boats where multiple charging sources and varying ground potentials can cause erratic behaviour in connected devices.\u003c\/p\u003e\n\u003cp\u003eAdditionally, the adjustable output voltage allows this converter to be used as a \u003cstrong\u003econstant voltage power supply\u003c\/strong\u003e for equipment that requires a specific voltage, such as LED lighting systems or certain telecommunications gear. Note: This unit is a DC-DC converter, not a multi-stage battery charger. For battery charging applications, see the Victron Orion-Tr Smart Charger range.\u003c\/p\u003e\n\u003ch3\u003eInstallation and Integration\u003c\/h3\u003e\n\u003cp\u003eInstallation is straightforward with clearly labelled screw terminals and a removable green remote on\/off connector. The remote port can be wired to a vehicle's ignition switch, a manual toggle, or a BMS control signal, allowing automated power management. The compact footprint and multiple mounting points make it easy to fit into existing electrical enclosures or tight spaces.\u003c\/p\u003e\n\u003cp\u003eFor higher power requirements, multiple units can be connected in parallel with no practical limit, providing a scalable solution that grows with your system.\u003c\/p\u003e\n\u003ch3\u003ePower Your Critical Systems with Confidence\u003c\/h3\u003e\n\u003cp\u003eWhen clean, stable DC power is essential, trust the \u003cstrong\u003eVictron Orion-Tr 24\/24-17\u003c\/strong\u003e to deliver. Whether you're outfitting a bluewater yacht, a remote off-grid cabin, or a mobile command vehicle, this isolated converter provides the reliability and performance that professionals demand. Add it to your power system today and eliminate electrical noise for good.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eOrion-Tr 24\/24-17 (400 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eInput voltage range (1)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e20-35 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage shut down\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e14 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage restart\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e15 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNominal output voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e24.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage adjust range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e20-30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage tolerance\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e+\/- 0.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput noise\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e2 mV rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output current at nominal output voltage and 40°C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e17 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum output current (10 s) at nominal output voltage minus 20%\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eShort circuit output current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output power at 25°C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e480 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output power at 40°C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e400 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEfficiency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e89%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNo load input current (2)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 80 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCurrent consumption\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 200uA when disabled via its remote port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eGalvanic isolation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e200 VDC between input, output and case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-20 to +55 °C (derate 3 % per °C above 40 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eHumidity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eMax. 95 % non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDC connection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum cable cross-section\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e16 mm2 AWG6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e1.6 kg (3.5 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions hxwxd\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e130 x 186 x 70 mm (5.1 x 7.3 x 2.8 inch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards: Safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 60950\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEmission\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-3, EN 55014-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eImmunity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-2, EN 61000-6-1, EN 55014-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eAutomotive Directive\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eECE R10-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364392988955,"sku":"VIC-ORI242441110","price":269.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/VIC-ORI242441110-01.jpg?v=1781658367"},{"product_id":"victron-orion-tr-24v-to-24v-5a-isolated-dc-dc-converter","title":"Victron Energy - 24V to 24V - Orion-Tr - 24\/24-5A - Isolated DC-DC Converter","description":"\u003ch2\u003eVictron Orion-Tr 24\/24-5A Isolated DC-DC Converter: Clean, Stable Power for Sensitive Electronics\u003c\/h2\u003e\n\u003ch3\u003eGalvanic Isolation for Superior Noise Rejection and System Protection\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eVictron Orion-Tr 24\/24-5A\u003c\/strong\u003e delivers a regulated, isolated DC output, making it the ideal solution for powering sensitive loads where electrical noise and ground loops cannot be tolerated. Unlike non-isolated converters, this unit provides \u003cstrong\u003e200V DC galvanic isolation\u003c\/strong\u003e between input, output, and case, effectively breaking ground loops and suppressing interference. This is critical for \u003cstrong\u003emarine electronics\u003c\/strong\u003e, \u003cstrong\u003ecommunications equipment\u003c\/strong\u003e, and \u003cstrong\u003eindustrial sensors\u003c\/strong\u003e where signal integrity is paramount.\u003c\/p\u003e\n\u003cp\u003eWith a wide input voltage range of 16-35V, it maintains a stable output even when the source voltage fluctuates, protecting your equipment from brownouts and surges. The output voltage is fully adjustable from 20-30V, allowing precise matching to your load requirements.\u003c\/p\u003e\n\u003ch3\u003eEngineered for Demanding Environments\u003c\/h3\u003e\n\u003cp\u003eBuilt on Victron's proven Orion platform, this converter features a rugged, compact design with an \u003cstrong\u003eIP43 protection rating\u003c\/strong\u003e when installed with terminals facing downwards. Mounted in a dry, protected location (humidity max. 95% non-condensing), it suits \u003cstrong\u003eoff-grid solar systems\u003c\/strong\u003e, \u003cstrong\u003evehicle-based installations\u003c\/strong\u003e and \u003cstrong\u003eboats\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003ePassive cooling via an integrated aluminium heatsink eliminates noisy fans and moving parts, reducing maintenance and points of failure. The wide operating temperature range of -20 to +55°C (derating above 40°C) ensures consistent performance across Australia's diverse climates, from the tropical north to the arid interior.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic isolation (200V DC)\u003c\/strong\u003e between input, output, and case eliminates ground loops and protects sensitive electronics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide input voltage range\u003c\/strong\u003e (16-35V) with under-voltage shutdown and restart for battery protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable output voltage\u003c\/strong\u003e (20-30V) for precise load matching\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote on\/off control\u003c\/strong\u003e via low-power switch eliminates need for high-current input wiring switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort circuit proof\u003c\/strong\u003e and capable of unlimited parallel connection for higher current demands\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh efficiency\u003c\/strong\u003e up to 87% reduces heat generation and wasted energy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP43 protection\u003c\/strong\u003e when installed with terminals downwards, for a dry, protected mounting location\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact and lightweight\u003c\/strong\u003e design with integrated heatsink for fanless operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScrew terminals\u003c\/strong\u003e accept cables up to 6 mm² for secure, low-resistance connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications Where Clean Power Matters\u003c\/h3\u003e\n\u003cp\u003eThis isolated DC-DC converter excels in scenarios where voltage stability and noise immunity are non-negotiable:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine electronics:\u003c\/strong\u003e Power navigation systems, autopilots, and communication radios without interference from engine alternators or inverters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCaravans and RVs:\u003c\/strong\u003e Provide stable 24V to sensitive appliances like compressor fridges, LED lighting, and entertainment systems, regardless of battery voltage sag.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-grid solar systems:\u003c\/strong\u003e Supply clean, isolated power to monitoring and control equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial and laboratory equipment:\u003c\/strong\u003e Isolate sensitive measurement instruments from noisy DC bus voltages in factories or test benches.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTelecommunications:\u003c\/strong\u003e Ensure reliable operation of remote radio repeaters and networking gear with a regulated, isolated supply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Choose an Isolated Converter?\u003c\/h3\u003e\n\u003cp\u003eStandard non-isolated DC-DC converters share a common ground between input and output, which can introduce electrical noise, ground loops, and potential damage to sensitive electronics. The Victron Orion-Tr isolated series breaks this connection, providing a 'floating' output that is electrically independent. This is especially important in vehicles and boats where multiple charging sources and varying ground potentials can cause erratic behaviour in connected devices.\u003c\/p\u003e\n\u003cp\u003eAdditionally, the adjustable output voltage allows this converter to be used as a \u003cstrong\u003econstant voltage power supply\u003c\/strong\u003e for equipment that requires a specific voltage, such as LED lighting systems or certain telecommunications gear. Note: This unit is a DC-DC converter, not a multi-stage battery charger. For battery charging applications, see the Victron Orion-Tr Smart Charger range.\u003c\/p\u003e\n\u003ch3\u003eInstallation and Integration\u003c\/h3\u003e\n\u003cp\u003eInstallation is straightforward with clearly labelled screw terminals and a removable green remote on\/off connector. The remote port can be wired to a vehicle's ignition switch, a manual toggle, or a BMS control signal, allowing automated power management. The compact footprint and multiple mounting points make it easy to fit into existing electrical enclosures or tight spaces.\u003c\/p\u003e\n\u003cp\u003eFor higher power requirements, multiple units can be connected in parallel with no practical limit, providing a scalable solution that grows with your system.\u003c\/p\u003e\n\u003ch3\u003ePower Your Critical Systems with Confidence\u003c\/h3\u003e\n\u003cp\u003eWhen clean, stable DC power is essential, trust the \u003cstrong\u003eVictron Orion-Tr 24\/24-5A\u003c\/strong\u003e to deliver. Whether you're outfitting a bluewater yacht, a remote off-grid cabin, or a mobile command vehicle, this isolated converter provides the reliability and performance that professionals demand. Add it to your power system today and eliminate electrical noise for good.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eInput voltage range (1)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e16-35 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage shut down\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e14 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage restart\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e15 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNominal output voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e24.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage adjust range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e20-30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage tolerance\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e+\/- 0.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput noise\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e2 mV rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output current at nominal output voltage and 25 °C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum output current (10 s) at nominal output voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e6.3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eShort circuit output current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output power at 25 °C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e120 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output power at 40 °C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e115 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEfficiency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e87 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNo load input current (2)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 60 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCurrent consumption\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 200 uA when disabled via remote port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eGalvanic isolation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e200 V dc between input, output and case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-20 to +55 °C (derate 3 % per °C above 40 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eHumidity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eMax. 95 % non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDC connection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum cable cross-section\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e6 mm² AWG10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e0.42 kg (1 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions h x w x d\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e100 x 113 x 47 mm (4.0 x 4.5 x 1.9 inch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards: Safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 60950\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEmission\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-3, EN 55014-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eImmunity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-2, EN 61000-6-1, EN 55014-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eAutomotive Directive\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eECE R10-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364393185563,"sku":"Vic-ORI242410110R","price":88.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/Vic-ORI242410110R-01.jpg?v=1781658361"},{"product_id":"victron-orion-tr-24v-to-48v-2-5a-isolated-dc-dc-converter","title":"Victron Energy - 24V to 48V - Orion-Tr - 24\/48-2.5A - Isolated DC-DC Converter","description":"\u003ch2\u003eVictron Orion-Tr 24\/48-2.5A Isolated DC-DC Converter: Clean, Stable Power for Sensitive Electronics\u003c\/h2\u003e\n\u003ch3\u003eGalvanic Isolation for Superior Noise Rejection and System Protection\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eVictron Orion-Tr 24\/48-2.5A\u003c\/strong\u003e delivers a regulated, isolated DC output, making it the ideal solution for powering sensitive loads where electrical noise and ground loops cannot be tolerated. Unlike non-isolated converters, this unit provides \u003cstrong\u003e200V DC galvanic isolation\u003c\/strong\u003e between input, output, and case, effectively breaking ground loops and suppressing interference. This is critical for \u003cstrong\u003emarine electronics\u003c\/strong\u003e, \u003cstrong\u003ecommunications equipment\u003c\/strong\u003e, and \u003cstrong\u003eindustrial sensors\u003c\/strong\u003e where signal integrity is paramount.\u003c\/p\u003e\n\u003cp\u003eWith a wide input voltage range of 16-35V, it maintains a stable output even when the source voltage fluctuates, protecting your equipment from brownouts and surges. The output voltage is fully adjustable from 40-60V, allowing precise matching to your load requirements.\u003c\/p\u003e\n\u003ch3\u003eEngineered for Demanding Environments\u003c\/h3\u003e\n\u003cp\u003eBuilt on Victron's proven Orion platform, this converter features a rugged, compact design with an \u003cstrong\u003eIP43 protection rating\u003c\/strong\u003e when installed with terminals facing downwards. Mounted in a dry, protected location (humidity max. 95% non-condensing), it suits \u003cstrong\u003eoff-grid solar systems\u003c\/strong\u003e, \u003cstrong\u003evehicle-based installations\u003c\/strong\u003e and \u003cstrong\u003eboats\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003ePassive cooling via an integrated aluminium heatsink eliminates noisy fans and moving parts, reducing maintenance and points of failure. The wide operating temperature range of -20 to +55°C (derating above 40°C) ensures consistent performance across Australia's diverse climates, from the tropical north to the arid interior.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic isolation (200V DC)\u003c\/strong\u003e between input, output, and case eliminates ground loops and protects sensitive electronics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide input voltage range\u003c\/strong\u003e (16-35V) with under-voltage shutdown and restart for battery protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable output voltage\u003c\/strong\u003e (40-60V) for precise load matching\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote on\/off control\u003c\/strong\u003e via low-power switch eliminates need for high-current input wiring switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort circuit proof\u003c\/strong\u003e and capable of unlimited parallel connection for higher current demands\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh efficiency\u003c\/strong\u003e up to 88% reduces heat generation and wasted energy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP43 protection\u003c\/strong\u003e when installed with terminals downwards, for a dry, protected mounting location\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact and lightweight\u003c\/strong\u003e design with integrated heatsink for fanless operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScrew terminals\u003c\/strong\u003e accept cables up to 6 mm² AWG10 for secure, low-resistance connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications Where Clean Power Matters\u003c\/h3\u003e\n\u003cp\u003eThis isolated DC-DC converter excels in scenarios where voltage stability and noise immunity are non-negotiable:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine electronics:\u003c\/strong\u003e Power navigation systems, autopilots, and communication radios without interference from engine alternators or inverters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCaravans and RVs:\u003c\/strong\u003e Provide a stable 48V supply to 48V equipment from a 24V bank, regardless of battery voltage sag.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-grid solar systems:\u003c\/strong\u003e Step voltage up or down between battery banks of different voltages, or supply clean power to monitoring and control equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial and laboratory equipment:\u003c\/strong\u003e Isolate sensitive measurement instruments from noisy DC bus voltages in factories or test benches.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTelecommunications:\u003c\/strong\u003e Ensure reliable operation of remote radio repeaters and networking gear with a regulated, isolated supply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Choose an Isolated Converter?\u003c\/h3\u003e\n\u003cp\u003eStandard non-isolated DC-DC converters share a common ground between input and output, which can introduce electrical noise, ground loops, and potential damage to sensitive electronics. The Victron Orion-Tr isolated series breaks this connection, providing a 'floating' output that is electrically independent. This is especially important in vehicles and boats where multiple charging sources and varying ground potentials can cause erratic behaviour in connected devices.\u003c\/p\u003e\n\u003cp\u003eAdditionally, the adjustable output voltage allows this converter to be used as a \u003cstrong\u003econstant voltage power supply\u003c\/strong\u003e for equipment that requires a specific voltage, such as LED lighting systems or certain telecommunications gear. Note: This unit is a DC-DC converter, not a multi-stage battery charger. For battery charging applications, see the Victron Orion-Tr Smart Charger range.\u003c\/p\u003e\n\u003ch3\u003eInstallation and Integration\u003c\/h3\u003e\n\u003cp\u003eInstallation is straightforward with clearly labelled screw terminals and a removable green remote on\/off connector. The remote port can be wired to a vehicle's ignition switch, a manual toggle, or a BMS control signal, allowing automated power management. The compact footprint and multiple mounting points make it easy to fit into existing electrical enclosures or tight spaces.\u003c\/p\u003e\n\u003cp\u003eFor higher power requirements, multiple units can be connected in parallel with no practical limit, providing a scalable solution that grows with your system.\u003c\/p\u003e\n\u003ch3\u003ePower Your Critical Systems with Confidence\u003c\/h3\u003e\n\u003cp\u003eWhen clean, stable DC power is essential, trust the \u003cstrong\u003eVictron Orion-Tr 24\/48-2.5A\u003c\/strong\u003e to deliver. Whether you're outfitting a bluewater yacht, a remote off-grid cabin, or a mobile command vehicle, this isolated converter provides the reliability and performance that professionals demand. Add it to your power system today and eliminate electrical noise for good.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eInput voltage range (1)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e16-35 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage shut down\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e14 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage restart\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e15 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNominal output voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e48.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage adjust range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e40-60 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage tolerance\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e+\/- 0.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput noise\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e2 mV rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output current at nominal output voltage and 25 °C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e2.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum output current (10 s) at nominal output voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e3.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eShort circuit output current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e19 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output power at 25 °C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e120 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output power at 40 °C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e115 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEfficiency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e88 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNo load input current (2)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 120 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCurrent consumption\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 200 uA when disabled via remote port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eGalvanic isolation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e200 V dc between input, output and case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-20 to +55 °C (derate 3 % per °C above 40 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eHumidity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eMax. 95 % non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDC connection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum cable cross-section\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e6 mm² AWG10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e0.42 kg (1 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions h x w x d\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e100 x 113 x 47 mm (4.0 x 4.5 x 1.9 inch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards: Safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 60950\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEmission\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-3, EN 55014-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eImmunity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-2, EN 61000-6-1, EN 55014-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eAutomotive Directive\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eECE R10-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364393382171,"sku":"Vic-ORI244810110","price":88.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/Vic-ORI244810110-01.jpg?v=1781658368"},{"product_id":"victron-orion-tr-24v-to-48v-6a-isolated-dc-dc-converter","title":"Victron Energy - 24V to 48V - Orion-Tr - 24\/48-6A - Isolated DC-DC Converter","description":"\u003ch2\u003eVictron Orion-Tr 24\/48-6A Isolated DC-DC Converter: Clean, Stable Power for Sensitive Electronics\u003c\/h2\u003e\n\u003ch3\u003eGalvanic Isolation for Superior Noise Rejection and System Protection\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eVictron Orion-Tr 24\/48-6A\u003c\/strong\u003e delivers a regulated, isolated DC output, making it the ideal solution for powering sensitive loads where electrical noise and ground loops cannot be tolerated. Unlike non-isolated converters, this unit provides \u003cstrong\u003e200V DC galvanic isolation\u003c\/strong\u003e between input, output, and case, effectively breaking ground loops and suppressing interference. This is critical for \u003cstrong\u003emarine electronics\u003c\/strong\u003e, \u003cstrong\u003ecommunications equipment\u003c\/strong\u003e, and \u003cstrong\u003eindustrial sensors\u003c\/strong\u003e where signal integrity is paramount.\u003c\/p\u003e\n\u003cp\u003eWith a wide input voltage range of 16-35V, it maintains a stable output even when the source voltage fluctuates, protecting your equipment from brownouts and surges. The output voltage is fully adjustable from 40-60V, allowing precise matching to your load requirements.\u003c\/p\u003e\n\u003ch3\u003eEngineered for Demanding Environments\u003c\/h3\u003e\n\u003cp\u003eBuilt on Victron's proven Orion platform, this converter features a rugged, compact design with an \u003cstrong\u003eIP43 protection rating\u003c\/strong\u003e when installed with terminals facing downwards. Mounted in a dry, protected location (humidity max. 95% non-condensing), it suits \u003cstrong\u003eoff-grid solar systems\u003c\/strong\u003e, \u003cstrong\u003evehicle-based installations\u003c\/strong\u003e and \u003cstrong\u003eboats\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003ePassive cooling via an integrated aluminium heatsink eliminates noisy fans and moving parts, reducing maintenance and points of failure. The wide operating temperature range of -20 to +55°C (derating above 40°C) ensures consistent performance across Australia's diverse climates, from the tropical north to the arid interior.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic isolation (200V DC)\u003c\/strong\u003e between input, output, and case eliminates ground loops and protects sensitive electronics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide input voltage range\u003c\/strong\u003e (16-35V) with under-voltage shutdown and restart for battery protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable output voltage\u003c\/strong\u003e (40-60V) for precise load matching\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote on\/off control\u003c\/strong\u003e via low-power switch eliminates need for high-current input wiring switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort circuit proof\u003c\/strong\u003e and capable of unlimited parallel connection for higher current demands\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh efficiency\u003c\/strong\u003e up to 89% reduces heat generation and wasted energy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP43 protection\u003c\/strong\u003e when installed with terminals downwards, for a dry, protected mounting location\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact and lightweight\u003c\/strong\u003e design with integrated heatsink for fanless operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScrew terminals\u003c\/strong\u003e accept cables up to 16 mm² (AWG6) for secure, low-resistance connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications Where Clean Power Matters\u003c\/h3\u003e\n\u003cp\u003eThis isolated DC-DC converter excels in scenarios where voltage stability and noise immunity are non-negotiable:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine electronics:\u003c\/strong\u003e Power navigation systems, autopilots, and communication radios without interference from engine alternators or inverters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCaravans and RVs:\u003c\/strong\u003e Provide a stable 48V supply to 48V equipment from a 24V bank, regardless of battery voltage sag.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-grid solar systems:\u003c\/strong\u003e Step voltage up or down between battery banks of different voltages, or supply clean power to monitoring and control equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial and laboratory equipment:\u003c\/strong\u003e Isolate sensitive measurement instruments from noisy DC bus voltages in factories or test benches.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTelecommunications:\u003c\/strong\u003e Ensure reliable operation of remote radio repeaters and networking gear with a regulated, isolated supply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Choose an Isolated Converter?\u003c\/h3\u003e\n\u003cp\u003eStandard non-isolated DC-DC converters share a common ground between input and output, which can introduce electrical noise, ground loops, and potential damage to sensitive electronics. The Victron Orion-Tr isolated series breaks this connection, providing a 'floating' output that is electrically independent. This is especially important in vehicles and boats where multiple charging sources and varying ground potentials can cause erratic behaviour in connected devices.\u003c\/p\u003e\n\u003cp\u003eAdditionally, the adjustable output voltage allows this converter to be used as a \u003cstrong\u003econstant voltage power supply\u003c\/strong\u003e for equipment that requires a specific voltage, such as LED lighting systems or certain telecommunications gear. Note: This unit is a DC-DC converter, not a multi-stage battery charger. For battery charging applications, see the Victron Orion-Tr Smart Charger range.\u003c\/p\u003e\n\u003ch3\u003eInstallation and Integration\u003c\/h3\u003e\n\u003cp\u003eInstallation is straightforward with clearly labelled screw terminals and a removable green remote on\/off connector. The remote port can be wired to a vehicle's ignition switch, a manual toggle, or a BMS control signal, allowing automated power management. The compact footprint and multiple mounting points make it easy to fit into existing electrical enclosures or tight spaces.\u003c\/p\u003e\n\u003cp\u003eFor higher power requirements, multiple units can be connected in parallel with no practical limit, providing a scalable solution that grows with your system.\u003c\/p\u003e\n\u003ch3\u003ePower Your Critical Systems with Confidence\u003c\/h3\u003e\n\u003cp\u003eWhen clean, stable DC power is essential, trust the \u003cstrong\u003eVictron Orion-Tr 24\/48-6A\u003c\/strong\u003e to deliver. Whether you're outfitting a bluewater yacht, a remote off-grid cabin, or a mobile command vehicle, this isolated converter provides the reliability and performance that professionals demand. Add it to your power system today and eliminate electrical noise for good.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eOrion-Tr 24\/48-6 (280 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eInput voltage range (1)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e16-35 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage shut down\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e14 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage restart\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e15 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNominal output voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e48.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage adjust range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e40-60 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage tolerance\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e+\/- 0.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput noise\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e2 mV rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output current at nominal output voltage and 40 °C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e6A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum output current (10 s) at nominal output voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eShort circuit output current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output power at 25 °C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e320 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output power at 40 °C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e280 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEfficiency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e89%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNo load input current (2)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 120 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCurrent consumption\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 200uA when disabled via its remote port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eGalvanic isolation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e200 VDC between input, output and case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-20 to +55 °C (derate 3 % per °C above 40 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eHumidity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eMax. 95 % non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDC connection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum cable cross-section\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e16 mm2 AWG6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e1.3 kg (3 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions h x w x d\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e130 x 186 x 70 mm (5.1 x 7.3 x 2.8 inch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards: Safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 60950\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards: Emission\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-3, EN 55014-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards: Immunity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-2, EN 61000-6-1, EN 55014-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards: Automotive Directive\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eECE R10-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364394594587,"sku":"Vic-ORI244828110","price":174.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/Vic-ORI244828110-01.jpg?v=1781658368"},{"product_id":"victron-orion-tr-24v-to-48v-8a-400w-isolated-dc-dc-converter","title":"Victron Energy - 24V to 48V - Orion-Tr - 24\/48-8.5A - Isolated DC-DC Converter","description":"\u003ch2\u003eVictron Orion-Tr 24\/48-8.5A Isolated DC-DC Converter: Clean, Stable Power for Sensitive Electronics\u003c\/h2\u003e\n\u003ch3\u003eGalvanic Isolation for Superior Noise Rejection and System Protection\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eVictron Orion-Tr 24\/48-8.5A\u003c\/strong\u003e delivers a regulated, isolated DC output, making it the ideal solution for powering sensitive loads where electrical noise and ground loops cannot be tolerated. Unlike non-isolated converters, this unit provides \u003cstrong\u003e200V DC galvanic isolation\u003c\/strong\u003e between input, output, and case, effectively breaking ground loops and suppressing interference. This is critical for \u003cstrong\u003emarine electronics\u003c\/strong\u003e, \u003cstrong\u003ecommunications equipment\u003c\/strong\u003e, and \u003cstrong\u003eindustrial sensors\u003c\/strong\u003e where signal integrity is paramount.\u003c\/p\u003e\n\u003cp\u003eWith a wide input voltage range of 20-35V, it maintains a stable output even when the source voltage fluctuates, protecting your equipment from brownouts and surges. The output voltage is fully adjustable from 40-60V, allowing precise matching to your load requirements.\u003c\/p\u003e\n\u003ch3\u003eEngineered for Demanding Environments\u003c\/h3\u003e\n\u003cp\u003eBuilt on Victron's proven Orion platform, this converter features a rugged, compact design with an \u003cstrong\u003eIP43 protection rating\u003c\/strong\u003e when installed with terminals facing downwards. Mounted in a dry, protected location (humidity max. 95% non-condensing), it suits \u003cstrong\u003eoff-grid solar systems\u003c\/strong\u003e, \u003cstrong\u003evehicle-based installations\u003c\/strong\u003e and \u003cstrong\u003eboats\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003ePassive cooling via an integrated aluminium heatsink eliminates noisy fans and moving parts, reducing maintenance and points of failure. The wide operating temperature range of -20 to +55°C (derating above 40°C) ensures consistent performance across Australia's diverse climates, from the tropical north to the arid interior.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic isolation (200V DC)\u003c\/strong\u003e between input, output, and case eliminates ground loops and protects sensitive electronics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide input voltage range\u003c\/strong\u003e (20-35V) with under-voltage shutdown and restart for battery protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable output voltage\u003c\/strong\u003e (40-60V) for precise load matching\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote on\/off control\u003c\/strong\u003e via low-power switch eliminates need for high-current input wiring switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort circuit proof\u003c\/strong\u003e and capable of unlimited parallel connection for higher current demands\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh efficiency\u003c\/strong\u003e up to 89% reduces heat generation and wasted energy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP43 protection\u003c\/strong\u003e when installed with terminals downwards, for a dry, protected mounting location\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact and lightweight\u003c\/strong\u003e design with integrated heatsink for fanless operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScrew terminals\u003c\/strong\u003e accept cables up to 16 mm² for secure, low-resistance connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications Where Clean Power Matters\u003c\/h3\u003e\n\u003cp\u003eThis isolated DC-DC converter excels in scenarios where voltage stability and noise immunity are non-negotiable:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine electronics:\u003c\/strong\u003e Power navigation systems, autopilots, and communication radios without interference from engine alternators or inverters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCaravans and RVs:\u003c\/strong\u003e Provide a stable 48V supply to 48V equipment from a 24V bank, regardless of battery voltage sag.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-grid solar systems:\u003c\/strong\u003e Step voltage up or down between battery banks of different voltages, or supply clean power to monitoring and control equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial and laboratory equipment:\u003c\/strong\u003e Isolate sensitive measurement instruments from noisy DC bus voltages in factories or test benches.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTelecommunications:\u003c\/strong\u003e Ensure reliable operation of remote radio repeaters and networking gear with a regulated, isolated supply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Choose an Isolated Converter?\u003c\/h3\u003e\n\u003cp\u003eStandard non-isolated DC-DC converters share a common ground between input and output, which can introduce electrical noise, ground loops, and potential damage to sensitive electronics. The Victron Orion-Tr isolated series breaks this connection, providing a 'floating' output that is electrically independent. This is especially important in vehicles and boats where multiple charging sources and varying ground potentials can cause erratic behaviour in connected devices.\u003c\/p\u003e\n\u003cp\u003eAdditionally, the adjustable output voltage allows this converter to be used as a \u003cstrong\u003econstant voltage power supply\u003c\/strong\u003e for equipment that requires a specific voltage, such as LED lighting systems or certain telecommunications gear. Note: This unit is a DC-DC converter, not a multi-stage battery charger. For battery charging applications, see the Victron Orion-Tr Smart Charger range.\u003c\/p\u003e\n\u003ch3\u003eInstallation and Integration\u003c\/h3\u003e\n\u003cp\u003eInstallation is straightforward with clearly labelled screw terminals and a removable green remote on\/off connector. The remote port can be wired to a vehicle's ignition switch, a manual toggle, or a BMS control signal, allowing automated power management. The compact footprint and multiple mounting points make it easy to fit into existing electrical enclosures or tight spaces.\u003c\/p\u003e\n\u003cp\u003eFor higher power requirements, multiple units can be connected in parallel with no practical limit, providing a scalable solution that grows with your system.\u003c\/p\u003e\n\u003ch3\u003ePower Your Critical Systems with Confidence\u003c\/h3\u003e\n\u003cp\u003eWhen clean, stable DC power is essential, trust the \u003cstrong\u003eVictron Orion-Tr 24\/48-8.5A\u003c\/strong\u003e to deliver. Whether you're outfitting a bluewater yacht, a remote off-grid cabin, or a mobile command vehicle, this isolated converter provides the reliability and performance that professionals demand. Add it to your power system today and eliminate electrical noise for good.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eOrion-Tr 24\/48-8.5 (400 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eInput voltage range (1)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e20-35 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage shut down\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e14 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage restart\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e15 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNominal output voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e48.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage adjust range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e40-60 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage tolerance\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e+\/- 0.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput noise\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e2 mV rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output current at nominal output voltage and 40°C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e8.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum output current (10 s) at nominal output voltage minus 20%\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eShort circuit output current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output power at 25°C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e480 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output power at 40°C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e400 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEfficiency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e89%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNo load input current (2)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 120 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCurrent consumption\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 200uA when disabled via its remote port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eGalvanic isolation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e200 VDC between input, output and case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-20 to +55 °C (derate 3 % per °C above 40 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eHumidity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eMax. 95 % non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDC connection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum cable cross-section\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e16 mm2 AWG6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e1.6 kg (3.5 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions hxwxd\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e130 x 186 x 70 mm (5.1 x 7.3 x 2.8 inch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards: Safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 60950\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEmission\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-3, EN 55014-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eImmunity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-2, EN 61000-6-1, EN 55014-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eAutomotive Directive\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eECE R10-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364394692891,"sku":"VIC-ORI244841110","price":309.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/VIC-ORI244841110-01.jpg?v=1781658368"},{"product_id":"victron-orion-tr-48v-12v-9a-isolated-dc-dc-converter","title":"Victron Energy - 48V to 12V - Orion-Tr - 48\/12-9A - Isolated DC-DC Converter","description":"\u003ch2\u003eVictron Orion-Tr 48\/12-9A Isolated DC-DC Converter: Clean, Stable Power for Sensitive Electronics\u003c\/h2\u003e\n\u003ch3\u003eGalvanic Isolation for Superior Noise Rejection and System Protection\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eVictron Orion-Tr 48\/12-9A\u003c\/strong\u003e delivers a regulated, isolated DC output, making it the ideal solution for powering sensitive loads where electrical noise and ground loops cannot be tolerated. Unlike non-isolated converters, this unit provides \u003cstrong\u003e200V DC galvanic isolation\u003c\/strong\u003e between input, output, and case, effectively breaking ground loops and suppressing interference. This is critical for \u003cstrong\u003emarine electronics\u003c\/strong\u003e, \u003cstrong\u003ecommunications equipment\u003c\/strong\u003e, and \u003cstrong\u003eindustrial sensors\u003c\/strong\u003e where signal integrity is paramount.\u003c\/p\u003e\n\u003cp\u003eWith a wide input voltage range of 32-70V, it maintains a stable output even when the source voltage fluctuates, protecting your equipment from brownouts and surges. The output voltage is fully adjustable from 10-15V, allowing precise matching to your load requirements.\u003c\/p\u003e\n\u003ch3\u003eEngineered for Demanding Environments\u003c\/h3\u003e\n\u003cp\u003eBuilt on Victron's proven Orion platform, this converter features a rugged, compact design with an \u003cstrong\u003eIP43 protection rating\u003c\/strong\u003e when installed with terminals facing downwards. Mounted in a dry, protected location (humidity max. 95% non-condensing), it suits \u003cstrong\u003eoff-grid solar systems\u003c\/strong\u003e, \u003cstrong\u003evehicle-based installations\u003c\/strong\u003e and \u003cstrong\u003eboats\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003ePassive cooling via an integrated aluminium heatsink eliminates noisy fans and moving parts, reducing maintenance and points of failure. The wide operating temperature range of -20 to +55°C (derating above 40°C) ensures consistent performance across Australia's diverse climates, from the tropical north to the arid interior.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic isolation (200V DC)\u003c\/strong\u003e between input, output, and case eliminates ground loops and protects sensitive electronics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide input voltage range\u003c\/strong\u003e (32-70V) with under-voltage shutdown and restart for battery protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable output voltage\u003c\/strong\u003e (10-15V) for precise load matching\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote on\/off control\u003c\/strong\u003e via low-power switch eliminates need for high-current input wiring switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort circuit proof\u003c\/strong\u003e and capable of unlimited parallel connection for higher current demands\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh efficiency\u003c\/strong\u003e up to 87% reduces heat generation and wasted energy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP43 protection\u003c\/strong\u003e when installed with terminals downwards, for a dry, protected mounting location\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact and lightweight\u003c\/strong\u003e design with integrated heatsink for fanless operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScrew terminals\u003c\/strong\u003e accept cables up to 6 mm² for secure, low-resistance connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications Where Clean Power Matters\u003c\/h3\u003e\n\u003cp\u003eThis isolated DC-DC converter excels in scenarios where voltage stability and noise immunity are non-negotiable:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine electronics:\u003c\/strong\u003e Power navigation systems, autopilots, and communication radios without interference from engine alternators or inverters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCaravans and RVs:\u003c\/strong\u003e Provide stable 12V to sensitive appliances like compressor fridges, LED lighting, and entertainment systems, regardless of battery voltage sag.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-grid solar systems:\u003c\/strong\u003e Step voltage down from 48V battery banks to supply clean power to monitoring and control equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial and laboratory equipment:\u003c\/strong\u003e Isolate sensitive measurement instruments from noisy DC bus voltages in factories or test benches.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTelecommunications:\u003c\/strong\u003e Ensure reliable operation of remote radio repeaters and networking gear with a regulated, isolated supply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Choose an Isolated Converter?\u003c\/h3\u003e\n\u003cp\u003eStandard non-isolated DC-DC converters share a common ground between input and output, which can introduce electrical noise, ground loops, and potential damage to sensitive electronics. The Victron Orion-Tr isolated series breaks this connection, providing a 'floating' output that is electrically independent. This is especially important in vehicles and boats where multiple charging sources and varying ground potentials can cause erratic behaviour in connected devices.\u003c\/p\u003e\n\u003cp\u003eAdditionally, the adjustable output voltage allows this converter to be used as a \u003cstrong\u003econstant voltage power supply\u003c\/strong\u003e for equipment that requires a specific voltage, such as LED lighting systems or certain telecommunications gear. Note: This unit is a DC-DC converter, not a multi-stage battery charger. For battery charging applications, see the Victron Orion-Tr Smart Charger range.\u003c\/p\u003e\n\u003ch3\u003eInstallation and Integration\u003c\/h3\u003e\n\u003cp\u003eInstallation is straightforward with clearly labelled screw terminals and a removable green remote on\/off connector. The remote port can be wired to a vehicle's ignition switch, a manual toggle, or a BMS control signal, allowing automated power management. The compact footprint and multiple mounting points make it easy to fit into existing electrical enclosures or tight spaces.\u003c\/p\u003e\n\u003cp\u003eFor higher power requirements, multiple units can be connected in parallel with no practical limit, providing a scalable solution that grows with your system.\u003c\/p\u003e\n\u003ch3\u003ePower Your Critical Systems with Confidence\u003c\/h3\u003e\n\u003cp\u003eWhen clean, stable DC power is essential, trust the \u003cstrong\u003eVictron Orion-Tr 48\/12-9A\u003c\/strong\u003e to deliver. Whether you're outfitting a bluewater yacht, a remote off-grid cabin, or a mobile command vehicle, this isolated converter provides the reliability and performance that professionals demand. Add it to your power system today and eliminate electrical noise for good.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eInput voltage range (1)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e32-70 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage shut down\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e28 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage restart\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNominal output voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e12.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage adjust range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e10-15 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage tolerance\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e+\/- 0.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput noise\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e2 mV rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output current at nominal output voltage and 25 °C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum output current (10 s) at nominal output voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e12.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eShort circuit output current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e27 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output power at 25 °C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e110 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output power at 40 °C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e85 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEfficiency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e87 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNo load input current (2)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCurrent consumption\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 200 uA when disabled via remote port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eGalvanic isolation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e200 V dc between input, output and case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-20 to +55 °C (derate 3 % per °C above 40 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eHumidity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eMax. 95 % non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDC connection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum cable cross-section\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e6 mm² AWG10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e0.42 kg (1 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions h x w x d\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e100 x 113 x 47 mm (4.0 x 4.5 x 1.9 inch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards: Safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 60950\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEmission\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-3, EN 55014-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eImmunity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-2, EN 61000-6-1, EN 55014-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eAutomotive Directive\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eECE R10-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364394791195,"sku":"Vic-ORI481210110","price":88.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/Vic-ORI481210110-01.jpg?v=1781658370"},{"product_id":"victron-orion-tr-48v-to-12v-20a-isolated-dc-dc-converter","title":"Victron Energy - 48V to 12V - Orion-Tr - 48\/12-20A - Isolated DC-DC Converter","description":"\u003ch2\u003eVictron Orion-Tr 48\/12-20 Isolated DC-DC Converter: Clean, Stable Power for Sensitive Electronics\u003c\/h2\u003e\n\u003ch3\u003eGalvanic Isolation for Superior Noise Rejection and System Protection\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eVictron Orion-Tr 48\/12-20\u003c\/strong\u003e delivers a regulated, isolated DC output, making it the ideal solution for powering sensitive loads where electrical noise and ground loops cannot be tolerated. Unlike non-isolated converters, this unit provides \u003cstrong\u003e200V DC galvanic isolation\u003c\/strong\u003e between input, output, and case, effectively breaking ground loops and suppressing interference. This is critical for \u003cstrong\u003emarine electronics\u003c\/strong\u003e, \u003cstrong\u003ecommunications equipment\u003c\/strong\u003e, and \u003cstrong\u003eindustrial sensors\u003c\/strong\u003e where signal integrity is paramount.\u003c\/p\u003e\n\u003cp\u003eWith a wide input voltage range of 32-70V, it maintains a stable output even when the source voltage fluctuates, protecting your equipment from brownouts and surges. The output voltage is fully adjustable from 10-15V, allowing precise matching to your load requirements.\u003c\/p\u003e\n\u003ch3\u003eEngineered for Demanding Environments\u003c\/h3\u003e\n\u003cp\u003eBuilt on Victron's proven Orion platform, this converter features a rugged, compact design with an \u003cstrong\u003eIP43 protection rating\u003c\/strong\u003e when installed with terminals facing downwards. Mounted in a dry, protected location (humidity max. 95% non-condensing), it suits \u003cstrong\u003eoff-grid solar systems\u003c\/strong\u003e, \u003cstrong\u003evehicle-based installations\u003c\/strong\u003e and \u003cstrong\u003eboats\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003ePassive cooling via an integrated aluminium heatsink eliminates noisy fans and moving parts, reducing maintenance and points of failure. The wide operating temperature range of -20 to +55°C (derating above 40°C) ensures consistent performance across Australia's diverse climates, from the tropical north to the arid interior.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic isolation (200V DC)\u003c\/strong\u003e between input, output, and case eliminates ground loops and protects sensitive electronics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide input voltage range\u003c\/strong\u003e (32-70V) with under-voltage shutdown and restart for battery protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable output voltage\u003c\/strong\u003e (10-15V) for precise load matching\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote on\/off control\u003c\/strong\u003e via low-power switch eliminates need for high-current input wiring switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort circuit proof\u003c\/strong\u003e and capable of unlimited parallel connection for higher current demands\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh efficiency\u003c\/strong\u003e up to 87% reduces heat generation and wasted energy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP43 protection\u003c\/strong\u003e when installed with terminals downwards, for a dry, protected mounting location\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact and lightweight\u003c\/strong\u003e design with integrated heatsink for fanless operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScrew terminals\u003c\/strong\u003e accept cables up to 16 mm² AWG6 for secure, low-resistance connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications Where Clean Power Matters\u003c\/h3\u003e\n\u003cp\u003eThis isolated DC-DC converter excels in scenarios where voltage stability and noise immunity are non-negotiable:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine electronics:\u003c\/strong\u003e Power navigation systems, autopilots, and communication radios without interference from engine alternators or inverters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCaravans and RVs:\u003c\/strong\u003e Provide stable 12V to sensitive appliances like compressor fridges, LED lighting, and entertainment systems, regardless of battery voltage sag.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-grid solar systems:\u003c\/strong\u003e Step voltage down from 48V to 12V for monitoring and control equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial and laboratory equipment:\u003c\/strong\u003e Isolate sensitive measurement instruments from noisy DC bus voltages in factories or test benches.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTelecommunications:\u003c\/strong\u003e Ensure reliable operation of remote radio repeaters and networking gear with a regulated, isolated supply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Choose an Isolated Converter?\u003c\/h3\u003e\n\u003cp\u003eStandard non-isolated DC-DC converters share a common ground between input and output, which can introduce electrical noise, ground loops, and potential damage to sensitive electronics. The Victron Orion-Tr isolated series breaks this connection, providing a 'floating' output that is electrically independent. This is especially important in vehicles and boats where multiple charging sources and varying ground potentials can cause erratic behaviour in connected devices.\u003c\/p\u003e\n\u003cp\u003eAdditionally, the adjustable output voltage allows this converter to be used as a \u003cstrong\u003econstant voltage power supply\u003c\/strong\u003e for equipment that requires a specific voltage, such as LED lighting systems or certain telecommunications gear. Note: This unit is a DC-DC converter, not a multi-stage battery charger. For battery charging applications, see the Victron Orion-Tr Smart Charger range.\u003c\/p\u003e\n\u003ch3\u003eInstallation and Integration\u003c\/h3\u003e\n\u003cp\u003eInstallation is straightforward with clearly labelled screw terminals and a removable green remote on\/off connector. The remote port can be wired to a vehicle's ignition switch, a manual toggle, or a BMS control signal, allowing automated power management. The compact footprint and multiple mounting points make it easy to fit into existing electrical enclosures or tight spaces.\u003c\/p\u003e\n\u003cp\u003eFor higher power requirements, multiple units can be connected in parallel with no practical limit, providing a scalable solution that grows with your system.\u003c\/p\u003e\n\u003ch3\u003ePower Your Critical Systems with Confidence\u003c\/h3\u003e\n\u003cp\u003eWhen clean, stable DC power is essential, trust the \u003cstrong\u003eVictron Orion-Tr 48\/12-20\u003c\/strong\u003e to deliver. Whether you're outfitting a bluewater yacht, a remote off-grid cabin, or a mobile command vehicle, this isolated converter provides the reliability and performance that professionals demand. Add it to your power system today and eliminate electrical noise for good.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eOrion-Tr 48\/12-20 (240 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eInput voltage range (1)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e32-70 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage shut down\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e28 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage restart\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNominal output voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e12.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage adjust range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e10-15 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage tolerance\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e+\/- 0.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput noise\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e2 mV rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output current at nominal output voltage and 40 °C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum output current (10 s) at nominal output voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eShort circuit output current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output power at 25 °C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e280 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output power at 40 °C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e240 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEfficiency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e87%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNo load input current (2)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 80 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCurrent consumption\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 200uA when disabled via its remote port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eGalvanic isolation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e200 VDC between input, output and case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-20 to +55 °C (derate 3 % per °C above 40 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eHumidity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eMax. 95 % non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDC connection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum cable cross-section\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e16 mm2 AWG6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e1.3 kg (3 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions h x w x d\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e130 x 186 x 70 mm (5.1 x 7.3 x 2.8 inch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards: Safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 60950\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards: Emission\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-3, EN 55014-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards: Immunity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-2, EN 61000-6-1, EN 55014-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards: Automotive Directive\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eECE R10-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364395217179,"sku":"Vic-ORI481224110","price":174.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/Vic-ORI481224110-01.jpg?v=1781658369"},{"product_id":"victron-orion-tr-48v-to-12v-30a-isolated-dc-dc-converter","title":"Victron Energy - 48V to 12V - Orion-Tr - 48\/12-30A - Isolated DC-DC Converter","description":"\u003ch2\u003eVictron 48V to 12V Orion-Tr 48\/12-30A Isolated DC-DC Converter: Clean, Stable Power for Sensitive Electronics\u003c\/h2\u003e\n\u003ch3\u003eGalvanic Isolation for Superior Noise Rejection and System Protection\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eVictron 48V to 12V Orion-Tr 48\/12-30A\u003c\/strong\u003e delivers a regulated, isolated DC output, making it the ideal solution for powering sensitive loads where electrical noise and ground loops cannot be tolerated. Unlike non-isolated converters, this unit provides \u003cstrong\u003e200V DC galvanic isolation\u003c\/strong\u003e between input, output, and case, effectively breaking ground loops and suppressing interference. This is critical for \u003cstrong\u003emarine electronics\u003c\/strong\u003e, \u003cstrong\u003ecommunications equipment\u003c\/strong\u003e, and \u003cstrong\u003eindustrial sensors\u003c\/strong\u003e where signal integrity is paramount.\u003c\/p\u003e\n\u003cp\u003eWith a wide input voltage range of 32-70V, it maintains a stable output even when the source voltage fluctuates, protecting your equipment from brownouts and surges. The output voltage is fully adjustable from 10-15V, allowing precise matching to your load requirements.\u003c\/p\u003e\n\u003ch3\u003eEngineered for Demanding Environments\u003c\/h3\u003e\n\u003cp\u003eBuilt on Victron's proven Orion platform, this converter features a rugged, compact design with an \u003cstrong\u003eIP43 protection rating\u003c\/strong\u003e when installed with terminals facing downwards. The fully potted electronics and conformal-coated PCB resist moisture, dust, and vibration, ensuring long-term reliability in \u003cstrong\u003eoff-grid solar systems\u003c\/strong\u003e, \u003cstrong\u003evehicle-based installations\u003c\/strong\u003e, and \u003cstrong\u003emarine engine rooms\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003ePassive cooling via an integrated aluminium heatsink eliminates noisy fans and moving parts, reducing maintenance and points of failure. The wide operating temperature range of -20 to +55°C (derating above 40°C) ensures consistent performance across Australia's diverse climates, from the tropical north to the arid interior.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic isolation (200V DC)\u003c\/strong\u003e between input, output, and case eliminates ground loops and protects sensitive electronics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide input voltage range\u003c\/strong\u003e (32-70V) with under-voltage shutdown and restart for battery protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable output voltage\u003c\/strong\u003e (10-15V) for precise load matching\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote on\/off control\u003c\/strong\u003e via low-power switch eliminates need for high-current input wiring switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort circuit proof\u003c\/strong\u003e and capable of unlimited parallel connection for higher current demands\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh efficiency\u003c\/strong\u003e up to 87% reduces heat generation and wasted energy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP43 protection\u003c\/strong\u003e when installed with terminals downwards, suitable for harsh environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact and lightweight\u003c\/strong\u003e design with integrated heatsink for fanless operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScrew terminals\u003c\/strong\u003e accept cables up to 16 mm² AWG6 for secure, low-resistance connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications Where Clean Power Matters\u003c\/h3\u003e\n\u003cp\u003eThis isolated DC-DC converter excels in scenarios where voltage stability and noise immunity are non-negotiable:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine electronics:\u003c\/strong\u003e Power navigation systems, autopilots, and communication radios without interference from engine alternators or inverters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCaravans and RVs:\u003c\/strong\u003e Provide stable 12V to sensitive appliances like compressor fridges, LED lighting, and entertainment systems, regardless of battery voltage sag.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-grid solar systems:\u003c\/strong\u003e Step voltage down between battery banks of different voltages, or supply clean power to monitoring and control equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial and laboratory equipment:\u003c\/strong\u003e Isolate sensitive measurement instruments from noisy DC bus voltages in factories or test benches.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTelecommunications:\u003c\/strong\u003e Ensure reliable operation of remote radio repeaters and networking gear with a regulated, isolated supply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Choose an Isolated Converter?\u003c\/h3\u003e\n\u003cp\u003eStandard non-isolated DC-DC converters share a common ground between input and output, which can introduce electrical noise, ground loops, and potential damage to sensitive electronics. The Victron Orion-Tr isolated series breaks this connection, providing a 'floating' output that is electrically independent. This is especially important in vehicles and boats where multiple charging sources and varying ground potentials can cause erratic behaviour in connected devices.\u003c\/p\u003e\n\u003cp\u003eAdditionally, the adjustable output voltage allows this converter to be used as a \u003cstrong\u003econstant voltage power supply\u003c\/strong\u003e for equipment that requires a specific voltage, such as LED lighting systems or certain telecommunications gear. Note: This unit is a DC-DC converter, not a multi-stage battery charger. For battery charging applications, see the Victron Orion-Tr Smart Charger range.\u003c\/p\u003e\n\u003ch3\u003eInstallation and Integration\u003c\/h3\u003e\n\u003cp\u003eInstallation is straightforward with clearly labelled screw terminals and a removable green remote on\/off connector. The remote port can be wired to a vehicle's ignition switch, a manual toggle, or a BMS control signal, allowing automated power management. The compact footprint and multiple mounting points make it easy to fit into existing electrical enclosures or tight spaces.\u003c\/p\u003e\n\u003cp\u003eFor higher power requirements, multiple units can be connected in parallel with no practical limit, providing a scalable solution that grows with your system.\u003c\/p\u003e\n\u003ch3\u003ePower Your Critical Systems with Confidence\u003c\/h3\u003e\n\u003cp\u003eWhen clean, stable DC power is essential, trust the \u003cstrong\u003eVictron 48V to 12V Orion-Tr 48\/12-30A\u003c\/strong\u003e to deliver. Whether you're outfitting a bluewater yacht, a remote off-grid cabin, or a mobile command vehicle, this isolated converter provides the reliability and performance that professionals demand. Add it to your power system today and eliminate electrical noise for good.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eOrion-Tr 48\/12-30 (360 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eInput voltage range (1)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e32-70 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage shut down\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e28 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage restart\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNominal output voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e12.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage adjust range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e10-15 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage tolerance\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e+\/- 0.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput noise\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e2 mV rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output current at nominal output voltage and 40°C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum output current (10 s) at nominal output voltage minus 20%\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eShort circuit output current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e60 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output power at 25°C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e430 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output power at 40°C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e360 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEfficiency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e87%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNo load input current (2)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 80 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCurrent consumption\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 200uA when disabled via its remote port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eGalvanic isolation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e200 VDC between input, output and case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-20 to +55 °C (derate 3 % per °C above 40 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eHumidity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eMax. 95 % non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDC connection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum cable cross-section\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e16 mm2 AWG6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e1.8 kg (4 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions hxwxd\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e130 x 186 x 80 mm (5.1 x 7.3 x 3.2 inch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards: Safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 60950\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEmission\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-3, EN 55014-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eImmunity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-2, EN 61000-6-1, EN 55014-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eAutomotive Directive\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eECE R10-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364395577627,"sku":"VIC-ORI481240110","price":259.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/VIC-ORI481240110-01.jpg?v=1781658467"},{"product_id":"victron-orion-tr-48v-to-24v-12a-isolated-dc-dc-converter","title":"Victron Energy - 48V to 24V - Orion-Tr - 48\/24-12A - Isolated DC-DC Converter","description":"\u003ch2\u003eVictron Orion-Tr 48\/24-12 Isolated DC-DC Converter: Clean, Stable Power for Sensitive Electronics\u003c\/h2\u003e\n\u003ch3\u003eGalvanic Isolation for Superior Noise Rejection and System Protection\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eVictron Orion-Tr 48\/24-12\u003c\/strong\u003e delivers a regulated, isolated DC output, making it the ideal solution for powering sensitive loads where electrical noise and ground loops cannot be tolerated. Unlike non-isolated converters, this unit provides \u003cstrong\u003e200V DC galvanic isolation\u003c\/strong\u003e between input, output, and case, effectively breaking ground loops and suppressing interference. This is critical for \u003cstrong\u003emarine electronics\u003c\/strong\u003e, \u003cstrong\u003ecommunications equipment\u003c\/strong\u003e, and \u003cstrong\u003eindustrial sensors\u003c\/strong\u003e where signal integrity is paramount.\u003c\/p\u003e\n\u003cp\u003eWith a wide input voltage range of 32-70V, it maintains a stable output even when the source voltage fluctuates, protecting your equipment from brownouts and surges. The output voltage is fully adjustable from 20-30V, allowing precise matching to your load requirements.\u003c\/p\u003e\n\u003ch3\u003eEngineered for Demanding Environments\u003c\/h3\u003e\n\u003cp\u003eBuilt on Victron's proven Orion platform, this converter features a rugged, compact design with an \u003cstrong\u003eIP43 protection rating\u003c\/strong\u003e when installed with terminals facing downwards. Mounted in a dry, protected location (humidity max. 95% non-condensing), it suits \u003cstrong\u003eoff-grid solar systems\u003c\/strong\u003e, \u003cstrong\u003evehicle-based installations\u003c\/strong\u003e and \u003cstrong\u003eboats\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003ePassive cooling via an integrated aluminium heatsink eliminates noisy fans and moving parts, reducing maintenance and points of failure. The wide operating temperature range of -20 to +55°C (derating above 40°C) ensures consistent performance across Australia's diverse climates, from the tropical north to the arid interior.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic isolation (200V DC)\u003c\/strong\u003e between input, output, and case eliminates ground loops and protects sensitive electronics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide input voltage range\u003c\/strong\u003e (32-70V) with under-voltage shutdown and restart for battery protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable output voltage\u003c\/strong\u003e (20-30V) for precise load matching\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote on\/off control\u003c\/strong\u003e via low-power switch eliminates need for high-current input wiring switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort circuit proof\u003c\/strong\u003e and capable of unlimited parallel connection for higher current demands\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh efficiency\u003c\/strong\u003e up to 89% reduces heat generation and wasted energy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP43 protection\u003c\/strong\u003e when installed with terminals downwards, for a dry, protected mounting location\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact and lightweight\u003c\/strong\u003e design with integrated heatsink for fanless operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScrew terminals\u003c\/strong\u003e accept cables up to 16 mm² AWG6 for secure, low-resistance connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications Where Clean Power Matters\u003c\/h3\u003e\n\u003cp\u003eThis isolated DC-DC converter excels in scenarios where voltage stability and noise immunity are non-negotiable:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine electronics:\u003c\/strong\u003e Power navigation systems, autopilots, and communication radios without interference from engine alternators or inverters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCaravans and RVs:\u003c\/strong\u003e Provide stable 24V to sensitive appliances like compressor fridges, LED lighting, and entertainment systems, regardless of battery voltage sag.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-grid solar systems:\u003c\/strong\u003e Step voltage down from 48V to 24V between battery banks of different voltages, or supply clean power to monitoring and control equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial and laboratory equipment:\u003c\/strong\u003e Isolate sensitive measurement instruments from noisy DC bus voltages in factories or test benches.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTelecommunications:\u003c\/strong\u003e Ensure reliable operation of remote radio repeaters and networking gear with a regulated, isolated supply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Choose an Isolated Converter?\u003c\/h3\u003e\n\u003cp\u003eStandard non-isolated DC-DC converters share a common ground between input and output, which can introduce electrical noise, ground loops, and potential damage to sensitive electronics. The Victron Orion-Tr isolated series breaks this connection, providing a 'floating' output that is electrically independent. This is especially important in vehicles and boats where multiple charging sources and varying ground potentials can cause erratic behaviour in connected devices.\u003c\/p\u003e\n\u003cp\u003eAdditionally, the adjustable output voltage allows this converter to be used as a \u003cstrong\u003econstant voltage power supply\u003c\/strong\u003e for equipment that requires a specific voltage, such as LED lighting systems or certain telecommunications gear. Note: This unit is a DC-DC converter, not a multi-stage battery charger. For battery charging applications, see the Victron Orion-Tr Smart Charger range.\u003c\/p\u003e\n\u003ch3\u003eInstallation and Integration\u003c\/h3\u003e\n\u003cp\u003eInstallation is straightforward with clearly labelled screw terminals and a removable green remote on\/off connector. The remote port can be wired to a vehicle's ignition switch, a manual toggle, or a BMS control signal, allowing automated power management. The compact footprint and multiple mounting points make it easy to fit into existing electrical enclosures or tight spaces.\u003c\/p\u003e\n\u003cp\u003eFor higher power requirements, multiple units can be connected in parallel with no practical limit, providing a scalable solution that grows with your system.\u003c\/p\u003e\n\u003ch3\u003ePower Your Critical Systems with Confidence\u003c\/h3\u003e\n\u003cp\u003eWhen clean, stable DC power is essential, trust the \u003cstrong\u003eVictron Orion-Tr 48\/24-12\u003c\/strong\u003e to deliver. Whether you're outfitting a bluewater yacht, a remote off-grid cabin, or a mobile command vehicle, this isolated converter provides the reliability and performance that professionals demand. Add it to your power system today and eliminate electrical noise for good.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eOrion-Tr 48\/24-12 (280 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eInput voltage range (1)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e32-70 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage shut down\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e28 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage restart\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNominal output voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e24.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage adjust range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e20-30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage tolerance\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e+\/- 0.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput noise\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e2 mV rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output current at nominal output voltage and 40 °C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e12 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum output current (10 s) at nominal output voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eShort circuit output current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output power at 25 °C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e320 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output power at 40 °C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e280 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEfficiency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e89%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNo load input current (2)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 80 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCurrent consumption\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 200uA when disabled via its remote port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eGalvanic isolation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e200 VDC between input, output and case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-20 to +55 °C (derate 3 % per °C above 40 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eHumidity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eMax. 95 % non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDC connection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum cable cross-section\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e16 mm2 AWG6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e1.3 kg (3 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions h x w x d\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e130 x 186 x 70 mm (5.1 x 7.3 x 2.8 inch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards: Safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 60950\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards: Emission\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-3, EN 55014-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards: Immunity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-2, EN 61000-6-1, EN 55014-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards: Automotive Directive\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eECE R10-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364395741467,"sku":"Vic-ORI482428110","price":164.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/Vic-ORI482428110-01.jpg?v=1781658483"},{"product_id":"victron-orion-tr-48v-to-24v-16a-isolated-dc-dc-converter","title":"Victron Energy - 48V to 24V - Orion-Tr - 48\/24-16A - Isolated DC-DC Converter","description":"\u003ch2\u003eVictron Orion-Tr 48\/24-16A Isolated DC-DC Converter: Clean, Stable Power for Sensitive Electronics\u003c\/h2\u003e\n\u003ch3\u003eGalvanic Isolation for Superior Noise Rejection and System Protection\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eVictron Orion-Tr 48\/24-16A\u003c\/strong\u003e delivers a regulated, isolated DC output, making it the ideal solution for powering sensitive loads where electrical noise and ground loops cannot be tolerated. Unlike non-isolated converters, this unit provides \u003cstrong\u003e200V DC galvanic isolation\u003c\/strong\u003e between input, output, and case, effectively breaking ground loops and suppressing interference. This is critical for \u003cstrong\u003emarine electronics\u003c\/strong\u003e, \u003cstrong\u003ecommunications equipment\u003c\/strong\u003e, and \u003cstrong\u003eindustrial sensors\u003c\/strong\u003e where signal integrity is paramount.\u003c\/p\u003e\n\u003cp\u003eWith a wide input voltage range of 40-70V, it maintains a stable output even when the source voltage fluctuates, protecting your equipment from brownouts and surges. The output voltage is fully adjustable from 20-30V, allowing precise matching to your load requirements.\u003c\/p\u003e\n\u003ch3\u003eEngineered for Demanding Environments\u003c\/h3\u003e\n\u003cp\u003eBuilt on Victron's proven Orion platform, this converter features a rugged, compact design with an \u003cstrong\u003eIP43 protection rating\u003c\/strong\u003e when installed with terminals facing downwards. Mounted in a dry, protected location (humidity max. 95% non-condensing), it suits \u003cstrong\u003eoff-grid solar systems\u003c\/strong\u003e, \u003cstrong\u003evehicle-based installations\u003c\/strong\u003e and \u003cstrong\u003eboats\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003ePassive cooling via an integrated aluminium heatsink eliminates noisy fans and moving parts, reducing maintenance and points of failure. The wide operating temperature range of -20 to +55°C (derating above 40°C) ensures consistent performance across Australia's diverse climates, from the tropical north to the arid interior.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic isolation (200V DC)\u003c\/strong\u003e between input, output, and case eliminates ground loops and protects sensitive electronics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide input voltage range\u003c\/strong\u003e (40-70V) with under-voltage shutdown and restart for battery protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable output voltage\u003c\/strong\u003e (20-30V) for precise load matching\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote on\/off control\u003c\/strong\u003e via low-power switch eliminates need for high-current input wiring switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort circuit proof\u003c\/strong\u003e and capable of unlimited parallel connection for higher current demands\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh efficiency\u003c\/strong\u003e up to 89% reduces heat generation and wasted energy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP43 protection\u003c\/strong\u003e when installed with terminals downwards, for a dry, protected mounting location\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact and lightweight\u003c\/strong\u003e design with integrated heatsink for fanless operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScrew terminals\u003c\/strong\u003e accept cables up to 16 mm² for secure, low-resistance connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications Where Clean Power Matters\u003c\/h3\u003e\n\u003cp\u003eThis isolated DC-DC converter excels in scenarios where voltage stability and noise immunity are non-negotiable:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine electronics:\u003c\/strong\u003e Power navigation systems, autopilots, and communication radios without interference from engine alternators or inverters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCaravans and RVs:\u003c\/strong\u003e Provide stable 24V to sensitive appliances like compressor fridges, LED lighting, and entertainment systems, regardless of battery voltage sag.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-grid solar systems:\u003c\/strong\u003e Step voltage down from 48V to 24V between battery banks of different voltages, or supply clean power to monitoring and control equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial and laboratory equipment:\u003c\/strong\u003e Isolate sensitive measurement instruments from noisy DC bus voltages in factories or test benches.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTelecommunications:\u003c\/strong\u003e Ensure reliable operation of remote radio repeaters and networking gear with a regulated, isolated supply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Choose an Isolated Converter?\u003c\/h3\u003e\n\u003cp\u003eStandard non-isolated DC-DC converters share a common ground between input and output, which can introduce electrical noise, ground loops, and potential damage to sensitive electronics. The Victron Orion-Tr isolated series breaks this connection, providing a 'floating' output that is electrically independent. This is especially important in vehicles and boats where multiple charging sources and varying ground potentials can cause erratic behaviour in connected devices.\u003c\/p\u003e\n\u003cp\u003eAdditionally, the adjustable output voltage allows this converter to be used as a \u003cstrong\u003econstant voltage power supply\u003c\/strong\u003e for equipment that requires a specific voltage, such as LED lighting systems or certain telecommunications gear. Note: This unit is a DC-DC converter, not a multi-stage battery charger. For battery charging applications, see the Victron Orion-Tr Smart Charger range.\u003c\/p\u003e\n\u003ch3\u003eInstallation and Integration\u003c\/h3\u003e\n\u003cp\u003eInstallation is straightforward with clearly labelled screw terminals and a removable green remote on\/off connector. The remote port can be wired to a vehicle's ignition switch, a manual toggle, or a BMS control signal, allowing automated power management. The compact footprint and multiple mounting points make it easy to fit into existing electrical enclosures or tight spaces.\u003c\/p\u003e\n\u003cp\u003eFor higher power requirements, multiple units can be connected in parallel with no practical limit, providing a scalable solution that grows with your system.\u003c\/p\u003e\n\u003ch3\u003ePower Your Critical Systems with Confidence\u003c\/h3\u003e\n\u003cp\u003eWhen clean, stable DC power is essential, trust the \u003cstrong\u003eVictron Orion-Tr 48\/24-16A\u003c\/strong\u003e to deliver. Whether you're outfitting a bluewater yacht, a remote off-grid cabin, or a mobile command vehicle, this isolated converter provides the reliability and performance that professionals demand. Add it to your power system today and eliminate electrical noise for good.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eOrion-Tr 48\/24-16 (380 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eInput voltage range (1)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e40-70 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage shut down\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e28 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage restart\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNominal output voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e24.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage adjust range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e20-30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage tolerance\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e+\/- 0.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput noise\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e2 mV rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output current at nominal output voltage and 40°C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum output current (10 s) at nominal output voltage minus 20%\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eShort circuit output current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output power at 25°C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e430 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output power at 40°C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e380 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEfficiency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e89%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNo load input current (2)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 80 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCurrent consumption\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 200uA when disabled via its remote port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eGalvanic isolation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e200 VDC between input, output and case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-20 to +55 °C (derate 3 % per °C above 40 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eHumidity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eMax. 95 % non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDC connection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum cable cross-section\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e16 mm2 AWG6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e1.6 kg (3.5 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions hxwxd\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e130 x 186 x 70 mm (5.1 x 7.3 x 2.8 inch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards: Safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 60950\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEmission\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-3, EN 55014-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eImmunity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-2, EN 61000-6-1, EN 55014-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eAutomotive Directive\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eECE R10-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364395938075,"sku":"VIC-ORI482441110","price":269.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/VIC-ORI482441110-01.jpg?v=1781658483"},{"product_id":"victron-orion-tr-48v-to-24v-5a-isolated-dc-dc-converter","title":"Victron Energy - 48V to 24V - Orion-Tr - 48\/24-5A - Isolated DC-DC Converter","description":"\u003ch2\u003eVictron 48V to 24V Orion-Tr 48\/24-5A Isolated DC-DC Converter: Clean, Stable Power for Sensitive Electronics\u003c\/h2\u003e\n\u003ch3\u003eGalvanic Isolation for Superior Noise Rejection and System Protection\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eVictron 48V to 24V Orion-Tr 48\/24-5A\u003c\/strong\u003e delivers a regulated, isolated DC output, making it the ideal solution for powering sensitive loads where electrical noise and ground loops cannot be tolerated. Unlike non-isolated converters, this unit provides \u003cstrong\u003e200V DC galvanic isolation\u003c\/strong\u003e between input, output, and case, effectively breaking ground loops and suppressing interference. This is critical for \u003cstrong\u003emarine electronics\u003c\/strong\u003e, \u003cstrong\u003ecommunications equipment\u003c\/strong\u003e, and \u003cstrong\u003eindustrial sensors\u003c\/strong\u003e where signal integrity is paramount.\u003c\/p\u003e\n\u003cp\u003eWith a wide input voltage range of 32-70V, it maintains a stable output even when the source voltage fluctuates, protecting your equipment from brownouts and surges. The output voltage is fully adjustable from 20-30V, allowing precise matching to your load requirements.\u003c\/p\u003e\n\u003ch3\u003eEngineered for Demanding Environments\u003c\/h3\u003e\n\u003cp\u003eBuilt on Victron's proven Orion platform, this converter features a rugged, compact design with an \u003cstrong\u003eIP43 protection rating\u003c\/strong\u003e when installed with terminals facing downwards. Mounted in a dry, protected location (humidity max. 95% non-condensing), it suits \u003cstrong\u003eoff-grid solar systems\u003c\/strong\u003e, \u003cstrong\u003evehicle-based installations\u003c\/strong\u003e and \u003cstrong\u003eboats\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003ePassive cooling via an integrated aluminium heatsink eliminates noisy fans and moving parts, reducing maintenance and points of failure. The wide operating temperature range of -20 to +55°C (derating above 40°C) ensures consistent performance across Australia's diverse climates, from the tropical north to the arid interior.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic isolation (200V DC)\u003c\/strong\u003e between input, output, and case eliminates ground loops and protects sensitive electronics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide input voltage range\u003c\/strong\u003e (32-70V) with under-voltage shutdown and restart for battery protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable output voltage\u003c\/strong\u003e (20-30V) for precise load matching\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote on\/off control\u003c\/strong\u003e via low-power switch eliminates need for high-current input wiring switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort circuit proof\u003c\/strong\u003e and capable of unlimited parallel connection for higher current demands\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh efficiency\u003c\/strong\u003e up to 86% reduces heat generation and wasted energy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP43 protection\u003c\/strong\u003e when installed with terminals downwards, for a dry, protected mounting location\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact and lightweight\u003c\/strong\u003e design with integrated heatsink for fanless operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScrew terminals\u003c\/strong\u003e accept cables up to 6 mm² AWG10 for secure, low-resistance connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications Where Clean Power Matters\u003c\/h3\u003e\n\u003cp\u003eThis isolated DC-DC converter excels in scenarios where voltage stability and noise immunity are non-negotiable:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine electronics:\u003c\/strong\u003e Power navigation systems, autopilots, and communication radios without interference from engine alternators or inverters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCaravans and RVs:\u003c\/strong\u003e Provide stable 24V to sensitive appliances like compressor fridges, LED lighting, and entertainment systems, regardless of battery voltage sag.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-grid solar systems:\u003c\/strong\u003e Step voltage down from 48V to 24V between battery banks, or supply clean power to monitoring and control equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial and laboratory equipment:\u003c\/strong\u003e Isolate sensitive measurement instruments from noisy DC bus voltages in factories or test benches.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTelecommunications:\u003c\/strong\u003e Ensure reliable operation of remote radio repeaters and networking gear with a regulated, isolated supply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Choose an Isolated Converter?\u003c\/h3\u003e\n\u003cp\u003eStandard non-isolated DC-DC converters share a common ground between input and output, which can introduce electrical noise, ground loops, and potential damage to sensitive electronics. The Victron Orion-Tr isolated series breaks this connection, providing a 'floating' output that is electrically independent. This is especially important in vehicles and boats where multiple charging sources and varying ground potentials can cause erratic behaviour in connected devices.\u003c\/p\u003e\n\u003cp\u003eAdditionally, the adjustable output voltage allows this converter to be used as a \u003cstrong\u003econstant voltage power supply\u003c\/strong\u003e for equipment that requires a specific voltage, such as LED lighting systems or certain telecommunications gear. Note: This unit is a DC-DC converter, not a multi-stage battery charger. For battery charging applications, see the Victron Orion-Tr Smart Charger range.\u003c\/p\u003e\n\u003ch3\u003eInstallation and Integration\u003c\/h3\u003e\n\u003cp\u003eInstallation is straightforward with clearly labelled screw terminals and a removable green remote on\/off connector. The remote port can be wired to a vehicle's ignition switch, a manual toggle, or a BMS control signal, allowing automated power management. The compact footprint and multiple mounting points make it easy to fit into existing electrical enclosures or tight spaces.\u003c\/p\u003e\n\u003cp\u003eFor higher power requirements, multiple units can be connected in parallel with no practical limit, providing a scalable solution that grows with your system.\u003c\/p\u003e\n\u003ch3\u003ePower Your Critical Systems with Confidence\u003c\/h3\u003e\n\u003cp\u003eWhen clean, stable DC power is essential, trust the \u003cstrong\u003eVictron 48V to 24V Orion-Tr 48\/24-5A\u003c\/strong\u003e to deliver. Whether you're outfitting a bluewater yacht, a remote off-grid cabin, or a mobile command vehicle, this isolated converter provides the reliability and performance that professionals demand. Add it to your power system today and eliminate electrical noise for good.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eInput voltage range (1)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e32-70 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage shut down\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e28 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage restart\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNominal output voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e24.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage adjust range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e20-30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage tolerance\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e+\/- 0.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput noise\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e2 mV rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output current at nominal output voltage and 25 °C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum output current (10 s) at nominal output voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e6.3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eShort circuit output current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output power at 25 °C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e120 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output power at 40 °C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e100 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEfficiency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e86 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNo load input current (2)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 60 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCurrent consumption\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 200 uA when disabled via remote port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eGalvanic isolation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e200 V dc between input, output and case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-20 to +55 °C (derate 3 % per °C above 40 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eHumidity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eMax. 95 % non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDC connection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum cable cross-section\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e6 mm² AWG10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e0.42 kg (1 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions h x w x d\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e100 x 113 x 47 mm (4.0 x 4.5 x 1.9 inch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards: Safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 60950\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEmission\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-3, EN 55014-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eImmunity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-2, EN 61000-6-1, EN 55014-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eAutomotive Directive\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eECE R10-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364396298523,"sku":"Vic-ORI482410110","price":88.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/Vic-ORI482410110-01.jpg?v=1781658481"},{"product_id":"victron-orion-tr-48v-to-48v-2-5a-isolated-dc-dc-converter","title":"Victron Energy - 48V to 48V - Orion-Tr - 48\/48-2.5A - Isolated DC-DC Converter","description":"\u003ch2\u003eVictron Orion-Tr 48\/48-2.5A Isolated DC-DC Converter: Clean, Stable Power for Sensitive Electronics\u003c\/h2\u003e\n\u003ch3\u003eGalvanic Isolation for Superior Noise Rejection and System Protection\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eVictron Orion-Tr 48\/48-2.5A\u003c\/strong\u003e delivers a regulated, isolated DC output, making it the ideal solution for powering sensitive loads where electrical noise and ground loops cannot be tolerated. Unlike non-isolated converters, this unit provides \u003cstrong\u003e200V DC galvanic isolation\u003c\/strong\u003e between input, output, and case, effectively breaking ground loops and suppressing interference. This is critical for \u003cstrong\u003emarine electronics\u003c\/strong\u003e, \u003cstrong\u003ecommunications equipment\u003c\/strong\u003e, and \u003cstrong\u003eindustrial sensors\u003c\/strong\u003e where signal integrity is paramount.\u003c\/p\u003e\n\u003cp\u003eWith a wide input voltage range of 32-70V, it maintains a stable output even when the source voltage fluctuates, protecting your equipment from brownouts and surges. The output voltage is fully adjustable from 40-60V, allowing precise matching to your load requirements.\u003c\/p\u003e\n\u003ch3\u003eEngineered for Demanding Environments\u003c\/h3\u003e\n\u003cp\u003eBuilt on Victron's proven Orion platform, this converter features a rugged, compact design with an \u003cstrong\u003eIP43 protection rating\u003c\/strong\u003e when installed with terminals facing downwards. Mounted in a dry, protected location (humidity max. 95% non-condensing), it suits \u003cstrong\u003eoff-grid solar systems\u003c\/strong\u003e, \u003cstrong\u003evehicle-based installations\u003c\/strong\u003e and \u003cstrong\u003eboats\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003ePassive cooling via an integrated aluminium heatsink eliminates noisy fans and moving parts, reducing maintenance and points of failure. The wide operating temperature range of -20 to +55°C (derating above 40°C) ensures consistent performance across Australia's diverse climates, from the tropical north to the arid interior.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic isolation (200V DC)\u003c\/strong\u003e between input, output, and case eliminates ground loops and protects sensitive electronics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide input voltage range\u003c\/strong\u003e (32-70V) with under-voltage shutdown and restart for battery protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable output voltage\u003c\/strong\u003e (40-60V) for precise load matching\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote on\/off control\u003c\/strong\u003e via low-power switch eliminates need for high-current input wiring switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort circuit proof\u003c\/strong\u003e and capable of unlimited parallel connection for higher current demands\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh efficiency\u003c\/strong\u003e up to 89% reduces heat generation and wasted energy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP43 protection\u003c\/strong\u003e when installed with terminals downwards, for a dry, protected mounting location\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact and lightweight\u003c\/strong\u003e design with integrated heatsink for fanless operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScrew terminals\u003c\/strong\u003e accept cables up to 6 mm² for secure, low-resistance connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications Where Clean Power Matters\u003c\/h3\u003e\n\u003cp\u003eThis isolated DC-DC converter excels in scenarios where voltage stability and noise immunity are non-negotiable:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine electronics:\u003c\/strong\u003e Power navigation systems, autopilots, and communication radios without interference from engine alternators or inverters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCaravans and RVs:\u003c\/strong\u003e Provide stable 48V to sensitive appliances like compressor fridges, LED lighting, and entertainment systems, regardless of battery voltage sag.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-grid solar systems:\u003c\/strong\u003e Supply clean, isolated power to monitoring and control equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial and laboratory equipment:\u003c\/strong\u003e Isolate sensitive measurement instruments from noisy DC bus voltages in factories or test benches.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTelecommunications:\u003c\/strong\u003e Ensure reliable operation of remote radio repeaters and networking gear with a regulated, isolated supply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Choose an Isolated Converter?\u003c\/h3\u003e\n\u003cp\u003eStandard non-isolated DC-DC converters share a common ground between input and output, which can introduce electrical noise, ground loops, and potential damage to sensitive electronics. The Victron Orion-Tr isolated series breaks this connection, providing a 'floating' output that is electrically independent. This is especially important in vehicles and boats where multiple charging sources and varying ground potentials can cause erratic behaviour in connected devices.\u003c\/p\u003e\n\u003cp\u003eAdditionally, the adjustable output voltage allows this converter to be used as a \u003cstrong\u003econstant voltage power supply\u003c\/strong\u003e for equipment that requires a specific voltage, such as LED lighting systems or certain telecommunications gear. Note: This unit is a DC-DC converter, not a multi-stage battery charger. For battery charging applications, see the Victron Orion-Tr Smart Charger range.\u003c\/p\u003e\n\u003ch3\u003eInstallation and Integration\u003c\/h3\u003e\n\u003cp\u003eInstallation is straightforward with clearly labelled screw terminals and a removable green remote on\/off connector. The remote port can be wired to a vehicle's ignition switch, a manual toggle, or a BMS control signal, allowing automated power management. The compact footprint and multiple mounting points make it easy to fit into existing electrical enclosures or tight spaces.\u003c\/p\u003e\n\u003cp\u003eFor higher power requirements, multiple units can be connected in parallel with no practical limit, providing a scalable solution that grows with your system.\u003c\/p\u003e\n\u003ch3\u003ePower Your Critical Systems with Confidence\u003c\/h3\u003e\n\u003cp\u003eWhen clean, stable DC power is essential, trust the \u003cstrong\u003eVictron Orion-Tr 48\/48-2.5A\u003c\/strong\u003e to deliver. Whether you're outfitting a bluewater yacht, a remote off-grid cabin, or a mobile command vehicle, this isolated converter provides the reliability and performance that professionals demand. Add it to your power system today and eliminate electrical noise for good.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eInput voltage range (1)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e32-70 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage shut down\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e28 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage restart\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNominal output voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e48.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage adjust range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e40-60 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage tolerance\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e+\/- 0.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput noise\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e2 mV rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output current at nominal output voltage and 25 °C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e2.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum output current (10 s) at nominal output voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e3.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eShort circuit output current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e17 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output power at 25 °C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e120 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output power at 40 °C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e85 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEfficiency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e89 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNo load input current (2)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 80 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCurrent consumption\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 200 uA when disabled via remote port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eGalvanic isolation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e200 V dc between input, output and case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-20 to +55 °C (derate 3 % per °C above 40 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eHumidity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eMax. 95 % non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDC connection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum cable cross-section\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e6 mm² AWG10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e0.42 kg (1 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions h x w x d\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e100 x 113 x 47 mm (4.0 x 4.5 x 1.9 inch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards: Safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 60950\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEmission\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-3, EN 55014-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eImmunity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-2, EN 61000-6-1, EN 55014-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eAutomotive Directive\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eECE R10-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364396658971,"sku":"Vic-ORI484810110","price":88.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/Vic-ORI484810110-01.jpg?v=1781658486"},{"product_id":"victron-orion-tr-48v-to-48v-6a-isolated-dc-dc-converter","title":"Victron Energy - 48V to 48V - Orion-Tr - 48\/48-6A - Isolated DC-DC Converter","description":"\u003ch2\u003eVictron Orion-Tr 48\/48-6A Isolated DC-DC Converter: Clean, Stable Power for Sensitive Electronics\u003c\/h2\u003e\n\u003ch3\u003eGalvanic Isolation for Superior Noise Rejection and System Protection\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eVictron Orion-Tr 48\/48-6A\u003c\/strong\u003e delivers a regulated, isolated DC output, making it the ideal solution for powering sensitive loads where electrical noise and ground loops cannot be tolerated. Unlike non-isolated converters, this unit provides \u003cstrong\u003e200V DC galvanic isolation\u003c\/strong\u003e between input, output, and case, effectively breaking ground loops and suppressing interference. This is critical for \u003cstrong\u003emarine electronics\u003c\/strong\u003e, \u003cstrong\u003ecommunications equipment\u003c\/strong\u003e, and \u003cstrong\u003eindustrial sensors\u003c\/strong\u003e where signal integrity is paramount.\u003c\/p\u003e\n\u003cp\u003eWith a wide input voltage range of 32-70V, it maintains a stable output even when the source voltage fluctuates, protecting your equipment from brownouts and surges. The output voltage is fully adjustable from 40-60V, allowing precise matching to your load requirements.\u003c\/p\u003e\n\u003ch3\u003eEngineered for Demanding Environments\u003c\/h3\u003e\n\u003cp\u003eBuilt on Victron's proven Orion platform, this converter features a rugged, compact design with an \u003cstrong\u003eIP43 protection rating\u003c\/strong\u003e when installed with terminals facing downwards. Mounted in a dry, protected location (humidity max. 95% non-condensing), it suits \u003cstrong\u003eoff-grid solar systems\u003c\/strong\u003e, \u003cstrong\u003evehicle-based installations\u003c\/strong\u003e and \u003cstrong\u003eboats\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003ePassive cooling via an integrated aluminium heatsink eliminates noisy fans and moving parts, reducing maintenance and points of failure. The wide operating temperature range of -20 to +55°C (derating above 40°C) ensures consistent performance across Australia's diverse climates, from the tropical north to the arid interior.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic isolation (200V DC)\u003c\/strong\u003e between input, output, and case eliminates ground loops and protects sensitive electronics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide input voltage range\u003c\/strong\u003e (32-70V) with under-voltage shutdown and restart for battery protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable output voltage\u003c\/strong\u003e (40-60V) for precise load matching\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote on\/off control\u003c\/strong\u003e via low-power switch eliminates need for high-current input wiring switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort circuit proof\u003c\/strong\u003e and capable of unlimited parallel connection for higher current demands\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh efficiency\u003c\/strong\u003e up to 89% reduces heat generation and wasted energy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP43 protection\u003c\/strong\u003e when installed with terminals downwards, for a dry, protected mounting location\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact and lightweight\u003c\/strong\u003e design with integrated heatsink for fanless operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScrew terminals\u003c\/strong\u003e accept cables up to 16 mm² AWG6 for secure, low-resistance connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications Where Clean Power Matters\u003c\/h3\u003e\n\u003cp\u003eThis isolated DC-DC converter excels in scenarios where voltage stability and noise immunity are non-negotiable:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine electronics:\u003c\/strong\u003e Power navigation systems, autopilots, and communication radios without interference from engine alternators or inverters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCaravans and RVs:\u003c\/strong\u003e Provide stable 48V to sensitive appliances like compressor fridges, LED lighting, and entertainment systems, regardless of battery voltage sag.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-grid solar systems:\u003c\/strong\u003e Supply clean, isolated power to monitoring and control equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial and laboratory equipment:\u003c\/strong\u003e Isolate sensitive measurement instruments from noisy DC bus voltages in factories or test benches.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTelecommunications:\u003c\/strong\u003e Ensure reliable operation of remote radio repeaters and networking gear with a regulated, isolated supply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Choose an Isolated Converter?\u003c\/h3\u003e\n\u003cp\u003eStandard non-isolated DC-DC converters share a common ground between input and output, which can introduce electrical noise, ground loops, and potential damage to sensitive electronics. The Victron Orion-Tr isolated series breaks this connection, providing a 'floating' output that is electrically independent. This is especially important in vehicles and boats where multiple charging sources and varying ground potentials can cause erratic behaviour in connected devices.\u003c\/p\u003e\n\u003cp\u003eAdditionally, the adjustable output voltage allows this converter to be used as a \u003cstrong\u003econstant voltage power supply\u003c\/strong\u003e for equipment that requires a specific voltage, such as LED lighting systems or certain telecommunications gear. Note: This unit is a DC-DC converter, not a multi-stage battery charger. For battery charging applications, see the Victron Orion-Tr Smart Charger range.\u003c\/p\u003e\n\u003ch3\u003eInstallation and Integration\u003c\/h3\u003e\n\u003cp\u003eInstallation is straightforward with clearly labelled screw terminals and a removable green remote on\/off connector. The remote port can be wired to a vehicle's ignition switch, a manual toggle, or a BMS control signal, allowing automated power management. The compact footprint and multiple mounting points make it easy to fit into existing electrical enclosures or tight spaces.\u003c\/p\u003e\n\u003cp\u003eFor higher power requirements, multiple units can be connected in parallel with no practical limit, providing a scalable solution that grows with your system.\u003c\/p\u003e\n\u003ch3\u003ePower Your Critical Systems with Confidence\u003c\/h3\u003e\n\u003cp\u003eWhen clean, stable DC power is essential, trust the \u003cstrong\u003eVictron Orion-Tr 48\/48-6A\u003c\/strong\u003e to deliver. Whether you're outfitting a bluewater yacht, a remote off-grid cabin, or a mobile command vehicle, this isolated converter provides the reliability and performance that professionals demand. Add it to your power system today and eliminate electrical noise for good.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eOrion-Tr 48\/48-6 (280 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eInput voltage range (1)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e32-70 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage shut down\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e28 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage restart\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNominal output voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e48.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage adjust range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e40-60 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage tolerance\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e+\/- 0.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput noise\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e2 mV rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output current at nominal output voltage and 40 °C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum output current (10 s) at nominal output voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eShort circuit output current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output power at 25 °C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e320 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output power at 40 °C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e280 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEfficiency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e89%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNo load input current (2)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 80 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCurrent consumption\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 200uA when disabled via its remote port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eGalvanic isolation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e200 VDC between input, output and case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-20 to +55 °C (derate 3 % per °C above 40 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eHumidity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eMax. 95 % non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDC connection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum cable cross-section\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e16 mm2 AWG6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e1.3 kg (3 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions h x w x d\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e130 x 186 x 70 mm (5.1 x 7.3 x 2.8 inch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards: Safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 60950\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards: Emission\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-3, EN 55014-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards: Immunity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-2, EN 61000-6-1, EN 55014-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards: Automotive Directive\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eECE R10-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364397117723,"sku":"Vic-ORI484828110","price":159.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/Vic-ORI484828110-01.jpg?v=1781658484"},{"product_id":"victron-orion-tr-48v-to-48v-8a-isolated-dc-dc-converter","title":"Victron Energy - 48V to 48V - Orion-Tr - 48\/48-8A - Isolated DC-DC Converter","description":"\u003ch2\u003eVictron Orion-Tr 48\/48-8 Isolated DC-DC Converter: Clean, Stable Power for Sensitive Electronics\u003c\/h2\u003e\n\u003ch3\u003eGalvanic Isolation for Superior Noise Rejection and System Protection\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eVictron Orion-Tr 48\/48-8\u003c\/strong\u003e delivers a regulated, isolated DC output, making it the ideal solution for powering sensitive loads where electrical noise and ground loops cannot be tolerated. Unlike non-isolated converters, this unit provides \u003cstrong\u003e200V DC galvanic isolation\u003c\/strong\u003e between input, output, and case, effectively breaking ground loops and suppressing interference. This is critical for \u003cstrong\u003emarine electronics\u003c\/strong\u003e, \u003cstrong\u003ecommunications equipment\u003c\/strong\u003e, and \u003cstrong\u003eindustrial sensors\u003c\/strong\u003e where signal integrity is paramount.\u003c\/p\u003e\n\u003cp\u003eWith a wide input voltage range of 40-70V, it maintains a stable output even when the source voltage fluctuates, protecting your equipment from brownouts and surges. The output voltage is fully adjustable from 40-60V, allowing precise matching to your load requirements.\u003c\/p\u003e\n\u003ch3\u003eEngineered for Demanding Environments\u003c\/h3\u003e\n\u003cp\u003eBuilt on Victron's proven Orion platform, this converter features a rugged, compact design with an \u003cstrong\u003eIP43 protection rating\u003c\/strong\u003e when installed with terminals facing downwards. Mounted in a dry, protected location (humidity max. 95% non-condensing), it suits \u003cstrong\u003eoff-grid solar systems\u003c\/strong\u003e, \u003cstrong\u003evehicle-based installations\u003c\/strong\u003e and \u003cstrong\u003eboats\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003ePassive cooling via an integrated aluminium heatsink eliminates noisy fans and moving parts, reducing maintenance and points of failure. The wide operating temperature range of -20 to +55°C (derating above 40°C) ensures consistent performance across Australia's diverse climates, from the tropical north to the arid interior.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic isolation (200V DC)\u003c\/strong\u003e between input, output, and case eliminates ground loops and protects sensitive electronics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide input voltage range\u003c\/strong\u003e (40-70V) with under-voltage shutdown and restart for battery protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable output voltage\u003c\/strong\u003e (40-60V) for precise load matching\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote on\/off control\u003c\/strong\u003e via low-power switch eliminates need for high-current input wiring switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort circuit proof\u003c\/strong\u003e and capable of unlimited parallel connection for higher current demands\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh efficiency\u003c\/strong\u003e up to 89% reduces heat generation and wasted energy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP43 protection\u003c\/strong\u003e when installed with terminals downwards, for a dry, protected mounting location\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact and lightweight\u003c\/strong\u003e design with integrated heatsink for fanless operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScrew terminals\u003c\/strong\u003e accept cables up to 16 mm² (AWG6) for secure, low-resistance connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications Where Clean Power Matters\u003c\/h3\u003e\n\u003cp\u003eThis isolated DC-DC converter excels in scenarios where voltage stability and noise immunity are non-negotiable:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine electronics:\u003c\/strong\u003e Power navigation systems, autopilots, and communication radios without interference from engine alternators or inverters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCaravans and RVs:\u003c\/strong\u003e Provide stable 48V to sensitive appliances like compressor fridges, LED lighting, and entertainment systems, regardless of battery voltage sag.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-grid solar systems:\u003c\/strong\u003e Supply clean, isolated power to monitoring and control equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial and laboratory equipment:\u003c\/strong\u003e Isolate sensitive measurement instruments from noisy DC bus voltages in factories or test benches.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTelecommunications:\u003c\/strong\u003e Ensure reliable operation of remote radio repeaters and networking gear with a regulated, isolated supply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Choose an Isolated Converter?\u003c\/h3\u003e\n\u003cp\u003eStandard non-isolated DC-DC converters share a common ground between input and output, which can introduce electrical noise, ground loops, and potential damage to sensitive electronics. The Victron Orion-Tr isolated series breaks this connection, providing a 'floating' output that is electrically independent. This is especially important in vehicles and boats where multiple charging sources and varying ground potentials can cause erratic behaviour in connected devices.\u003c\/p\u003e\n\u003cp\u003eAdditionally, the adjustable output voltage allows this converter to be used as a \u003cstrong\u003econstant voltage power supply\u003c\/strong\u003e for equipment that requires a specific voltage, such as LED lighting systems or certain telecommunications gear. Note: This unit is a DC-DC converter, not a multi-stage battery charger. For battery charging applications, see the Victron Orion-Tr Smart Charger range.\u003c\/p\u003e\n\u003ch3\u003eInstallation and Integration\u003c\/h3\u003e\n\u003cp\u003eInstallation is straightforward with clearly labelled screw terminals and a removable green remote on\/off connector. The remote port can be wired to a vehicle's ignition switch, a manual toggle, or a BMS control signal, allowing automated power management. The compact footprint and multiple mounting points make it easy to fit into existing electrical enclosures or tight spaces.\u003c\/p\u003e\n\u003cp\u003eFor higher power requirements, multiple units can be connected in parallel with no practical limit, providing a scalable solution that grows with your system.\u003c\/p\u003e\n\u003ch3\u003ePower Your Critical Systems with Confidence\u003c\/h3\u003e\n\u003cp\u003eWhen clean, stable DC power is essential, trust the \u003cstrong\u003eVictron Orion-Tr 48\/48-8\u003c\/strong\u003e to deliver. Whether you're outfitting a bluewater yacht, a remote off-grid cabin, or a mobile command vehicle, this isolated converter provides the reliability and performance that professionals demand. Add it to your power system today and eliminate electrical noise for good.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eOrion-Tr 48\/48-8 (380 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eInput voltage range (1)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e40-70 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage shut down\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e28 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder voltage restart\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNominal output voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e48.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage adjust range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e40-60 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput voltage tolerance\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e+\/- 0.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput noise\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e2 mV rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output current at nominal output voltage and 40°C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e8A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum output current (10 s) at nominal output voltage minus 20%\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eShort circuit output current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output power at 25°C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e430 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCont. output power at 40°C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e380 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEfficiency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e89%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eNo load input current (2)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 80 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCurrent consumption\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 200uA when disabled via its remote port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eGalvanic isolation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e200 VDC between input, output and case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-20 to +55 °C (derate 3 % per °C above 40 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eHumidity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eMax. 95 % non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDC connection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum cable cross-section\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e16 mm2 AWG6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e1.6 kg (3.5 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions hxwxd\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e130 x 186 x 70 mm (5.1 x 7.3 x 2.8 inch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards: Safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 60950\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEmission\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-3, EN 55014-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eImmunity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 61000-6-2, EN 61000-6-1, EN 55014-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eAutomotive Directive\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eECE R10-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364397248795,"sku":"VIC-ORI484841110","price":309.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/VIC-ORI484841110-01.jpg?v=1781658482"},{"product_id":"victron-energy-24v-to-12v-orion-24-12-30-non-isolated-dc-dc-converter","title":"Victron Energy - 24V to 12V - Orion 24\/12-30 Non-Isolated DC-DC Converter","description":"\u003ch2\u003eVictron Orion 24\/12-30 Non-Isolated DC-DC Converter\u003c\/h2\u003e\n\u003ch3\u003eHigh-Efficiency 24V to 12V Power Conversion\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eVictron Orion 24\/12-30\u003c\/strong\u003e steps a 24V DC supply down to a regulated 12V output, delivering up to \u003cstrong\u003e30A continuous\u003c\/strong\u003e (40A maximum) to run 12V equipment and accessories from a 24V vehicle, vessel or off-grid system. Synchronous rectification gives it a high \u003cstrong\u003e96% efficiency\u003c\/strong\u003e, minimising heat and wasted energy under sustained load.\u003c\/p\u003e\n\u003cp\u003eOutput voltage is adjustable from 10-15V (factory set to 13.2V), so besides simply converting voltage, the Orion 24\/12-30 can also buffer-charge a 12V starter or accessory battery in an otherwise 24V system. A \u003cstrong\u003eremote on\/off connector\u003c\/strong\u003e allows the converter to be switched with a low-power switch or an engine run\/stop signal, avoiding the need for a high-current switch in the input wiring. Multiple units can be connected in parallel to increase available output current.\u003c\/p\u003e\n\u003cp\u003eThis is a \u003cstrong\u003enon-isolated\u003c\/strong\u003e converter - input and output share a common negative - so it is not intended for applications requiring galvanic isolation between circuits. Power connections are made via 6.3mm Faston tabs, and the unit is rated for an operating temperature range of -20°C to +55°C, derating 3% per °C above 40°C.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e30A continuous \/ 40A maximum output\u003c\/strong\u003e at an adjustable 10-15V (factory set 13.2V)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e96% efficiency\u003c\/strong\u003e via synchronous rectification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote on\/off connector\u003c\/strong\u003e for low-power or ignition-linked switching\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eParallel-capable\u003c\/strong\u003e for higher combined output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-isolated design\u003c\/strong\u003e with 6.3mm Faston tab connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact and lightweight\u003c\/strong\u003e at 0.7kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eOrion 24\/12-30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eInput Voltage Range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e18-35V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder Voltage Shutdown \/ Restart\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e14V \/ 18V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput Voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eAdjustable 10-15V (factory set 13.2V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eContinuous Output Current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e30A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMax Output Current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEfficiency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOff-Load Current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 15mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eGalvanic Isolation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eNone (non-isolated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eRemote On\/Off\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOperating Temperature Range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-20°C to +55°C (derate 3% per °C above 40°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDC Connection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eFaston tabs, 6.3mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e0.7kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions (h x w x d)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e65 x 88 x 160mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":53941332345115,"sku":"VIC-ORI241230022","price":106.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/victron-orion-24-12-30a-dc-dc-converter-vic-ori241230022.webp?v=1789376854"},{"product_id":"victron-energy-48v-to-12v-orion-48-12-60-non-isolated-dc-dc-converter","title":"Victron Energy - 48V to 12V - Orion 48\/12-60 Non-Isolated DC-DC Converter","description":"\u003ch2\u003eVictron Orion 48\/12-60 Non-Isolated DC-DC Converter\u003c\/h2\u003e\n\u003ch3\u003eHigh-Power 48V to 12V Conversion and Battery Charging\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eVictron Orion 48\/12-60\u003c\/strong\u003e steps a 48V DC supply down to a regulated 12V output, delivering up to \u003cstrong\u003e60A continuous\u003c\/strong\u003e (65A maximum) to run 12V equipment, lighting and accessories from a 48V battery bank or system. A temperature-controlled cooling fan allows it to sustain this higher power level in a compact enclosure, at \u003cstrong\u003e92% efficiency\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eOutput voltage is adjustable from 10-15V (factory set to 13.2V) via an onboard potentiometer, so the Orion 48\/12-60 can also buffer-charge a 12V starter or accessory battery from a 48V system. It can be connected in parallel with other Orion 48\/12-60 units - up to five - to scale total output current, and a \u003cstrong\u003eremote on\/off connector\u003c\/strong\u003e allows it to be switched with a low-power switch or an engine run\/stop signal.\u003c\/p\u003e\n\u003cp\u003eThis is a \u003cstrong\u003enon-isolated\u003c\/strong\u003e converter - input and output share a common negative - so it is not intended for applications requiring galvanic isolation between circuits. Power connections are made via M6 bolts, and the unit is rated for an operating temperature range of -20°C to +55°C, derating 3% per °C above 40°C.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e60A continuous \/ 65A maximum output\u003c\/strong\u003e at an adjustable 10-15V (factory set 13.2V)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e92% efficiency\u003c\/strong\u003e with temperature-controlled fan-assisted cooling\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable to buffer-charge a 12V battery\u003c\/strong\u003e from a 48V system\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eParallel-capable\u003c\/strong\u003e - up to five units for higher combined output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote on\/off connector\u003c\/strong\u003e for low-power or ignition-linked switching\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-isolated design\u003c\/strong\u003e with M6 bolt DC connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eOrion 48\/12-60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eInput Voltage Range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e38-66V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnder Voltage Shutdown \/ Restart\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e38V \/ 40V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput Voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eAdjustable 10-15V (factory set 13.2V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eContinuous Output Current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e60A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMax Output Current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e65A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEfficiency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e92%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCooling\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eTemperature-controlled fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOff-Load Current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e\u0026lt; 20mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eGalvanic Isolation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eNone (non-isolated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eRemote On\/Off\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eParallel Operation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eYes - up to 5 units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOperating Temperature Range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-20°C to +55°C (derate 3% per °C above 40°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDC Connection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eM6 bolts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e0.9kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions (h x w x d)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e65 x 88 x 195mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":53941332607259,"sku":"VIC-ORI481260020","price":201.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/victron-orion-48-12-60a-dc-dc-converter-vic-ori481260020.webp?v=1789376861"}],"url":"https:\/\/www.nbcampingequipment.com.au\/collections\/dc-dc-converters.oembed","provider":"NB Camping Equipment","version":"1.0","type":"link"}