{"product_id":"solar-cable-62930-6mm2-twin-per-metre","title":"6mm² Twin IEC 62930 Solar Cable - Per Metre","description":"\u003ch2\u003e6mm² Twin Solar Cable – IEC 62930 1500V – Per Metre\u003c\/h2\u003e\n\u003ch3\u003eProfessional-Grade Solar Cable for Caravans, RVs, and Off-Grid Systems\u003c\/h3\u003e\n\u003cp\u003eEngineered for demanding solar installations, this \u003cstrong\u003e6mm² twin solar cable\u003c\/strong\u003e delivers reliable power transfer in \u003cstrong\u003e12V, 24V, and 48V solar systems\u003c\/strong\u003e. With a maximum DC voltage rating of \u003cstrong\u003e1500V\u003c\/strong\u003e, it exceeds the requirements of most residential and mobile setups, providing headroom for larger arrays and future expansion. The \u003cstrong\u003etinned copper conductors\u003c\/strong\u003e resist corrosion, ensuring low resistance and consistent performance over time—critical for installations exposed to moisture or coastal air.\u003c\/p\u003e\n\u003cp\u003eSold \u003cstrong\u003eper metre\u003c\/strong\u003e and cut to your specified length (up to 100m continuous), this cable reduces waste and allows precise budgeting for projects of any scale. The twin-core design keeps positive and negative conductors neatly paired, simplifying cable management and reducing installation time in tight spaces like caravan roofs or engine bays.\u003c\/p\u003e\n\u003ch3\u003eBuilt to IEC 62930: Safety and Longevity in Harsh Conditions\u003c\/h3\u003e\n\u003cp\u003eCompliance with \u003cstrong\u003eIEC 62930\u003c\/strong\u003e means this cable meets stringent international standards for solar PV applications. The \u003cstrong\u003ecross-linked polyethylene (XLPE) insulation and jacket\u003c\/strong\u003e provide excellent resistance to UV radiation, heat, and abrasion—common challenges in the Australian environment. Unlike standard PVC cables, XLPE maintains flexibility and dielectric strength across a wide temperature range (-40°C to +90°C), reducing the risk of insulation cracking or failure over decades of service.\u003c\/p\u003e\n\u003cp\u003eThe cable's \u003cstrong\u003eflame-retardant properties (IEC 60332-1-2)\u003c\/strong\u003e add an extra layer of safety, minimising fire propagation risk in the event of a fault. For installers, the \u003cstrong\u003edynamic bending radius of 8x outer diameter\u003c\/strong\u003e allows routing around obstacles without compromising conductor integrity.\u003c\/p\u003e\n\u003ch3\u003eOptimised Current Capacity for Medium to High-Power Systems\u003c\/h3\u003e\n\u003cp\u003eWith a \u003cstrong\u003emaximum current rating of 70A at 20°C\u003c\/strong\u003e, this 6mm² cable supports substantial power flows, making it suitable for connecting solar panels to charge controllers, battery banks, and inverters. The \u003cstrong\u003elow DC resistance (≤3.39 Ω\/km)\u003c\/strong\u003e minimises voltage drop, preserving system efficiency—especially important in low-voltage 12V setups where even small losses can impact charging performance. *Note: typical de-rating factors apply for elevated temperatures, bundling, or enclosed conduits.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTinned copper conductors\u003c\/strong\u003e for superior corrosion resistance and long-term low resistance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eXLPE insulation and jacket\u003c\/strong\u003e rated for 1500V DC and 1000V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUV and weather resistant\u003c\/strong\u003e for outdoor use in harsh Australian conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlame retardant\u003c\/strong\u003e to IEC 60332-1-2 for enhanced safety\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwin-core configuration\u003c\/strong\u003e simplifies wiring and reduces clutter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide temperature range\u003c\/strong\u003e (-40°C to +90°C) for reliable operation in extreme climates\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible yet robust\u003c\/strong\u003e with dynamic bend radius of 8x OD\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications Beyond the Basics\u003c\/h3\u003e\n\u003cp\u003eWhile ideal for \u003cstrong\u003ecaravan solar panels\u003c\/strong\u003e and \u003cstrong\u003eRV solar wiring\u003c\/strong\u003e, this cable excels in any off-grid or grid-tied PV system requiring durable, high-voltage DC connections. Use it for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInterconnecting solar panels in series or parallel\u003c\/li\u003e\n\u003cli\u003eLinking combiner boxes to charge controllers\u003c\/li\u003e\n\u003cli\u003eBattery-to-inverter cabling in 12V, 24V, or 48V banks\u003c\/li\u003e\n\u003cli\u003eMarine and coastal installations where salt spray is a concern\u003c\/li\u003e\n\u003cli\u003eRemote industrial monitoring and telemetry systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBy choosing a cable that meets \u003cstrong\u003eIEC 62930\u003c\/strong\u003e and \u003cstrong\u003eRoHS\u003c\/strong\u003e standards, you reduce the risk of premature failure, voltage drop issues, and safety hazards often associated with lower-grade alternatives. This translates to fewer maintenance visits and greater peace of mind for your energy system.\u003c\/p\u003e\n\u003ch3\u003eReady to Wire Your Solar Project?\u003c\/h3\u003e\n\u003cp\u003eSelect your required length and add this \u003cstrong\u003e6mm² twin solar cable\u003c\/strong\u003e to your order today. Whether you're upgrading a weekend camper or building a permanent off-grid installation, this cable provides the durability and efficiency your system deserves.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCable Type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eString Cable - Twin Core\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eConductor Size\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e6 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eConductor\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eStranded Tinned Copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStranding\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e78\/0.30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eConductor Diameter\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e3.06 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eInsulation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eXLPE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eInsulation Thickness\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e0.7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eInsulation Colour\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eBlack-Red\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eJacket\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eXLPE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eJacket Thickness\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e0.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eJacket Colour\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCable Diameter\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e6.1 ±0.15 mm × 12.3 ±0.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eVoltage Rating\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eAC: 1000 V; DC: Max. 1500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eInsulation Resistance At +20 °C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e≥ 610 MΩ km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eVoltage Withstand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e6500 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eConductor DC Resistance At +20 °C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e≤ 3.39 Ω\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum Current At +20 °C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e70 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eBending Radius, Dynamic\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e≥ 8 x OD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eBending Radius, Static\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e≥ 5 x OD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eFlammability\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eIEC 60332-1-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWorking Temperature\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-40 to +90 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCable Light Transmittance\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e≥ 60%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e62930 IEC 131, IEC 60332-1-2, IEC 60754, IEC 60811, IEC 61034, IEC 60228, RoHS 2011\/65\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Unbranded","offers":[{"title":"Default Title","offer_id":52364269748507,"sku":"62930-2x6MM","price":4.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/62930-2x6MM-01.jpg?v=1781608715","url":"https:\/\/www.nbcampingequipment.com.au\/products\/solar-cable-62930-6mm2-twin-per-metre","provider":"NB Camping Equipment","version":"1.0","type":"link"}