{"product_id":"victron-energy-63a-anti-islanding-box-single-and-three-phase","title":"Victron Energy - 63A - Anti-Islanding Box - Single and Three Phase","description":"\u003ch2\u003eVictron Anti-Islanding Box 63A: Pre-Wired Grid Protection for Single and Three-Phase ESS\u003c\/h2\u003e\n\u003ch3\u003eZiehl UFR1001E Relay, Contactors and Circuit Breaker in One IP65 Enclosure\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eVictron Anti-Islanding Box 63A\u003c\/strong\u003e is a pre-wired hardware disconnect solution for grid-feeding inverter\/charger installations that must meet an external, hardware-based anti-islanding requirement. It houses a \u003cstrong\u003eZiehl UFR1001E\u003c\/strong\u003e voltage and frequency relay together with two in-line contactors and a main circuit breaker in a single \u003cstrong\u003eIP65\u003c\/strong\u003e enclosure, rated up to \u003cstrong\u003e63A per phase\u003c\/strong\u003e for both single-phase and three-phase systems.\u003c\/p\u003e\n\u003cp\u003eThe Ziehl UFR1001E relay continuously monitors grid voltage, frequency, vector shift and rate-of-change-of-frequency (ROCOF), and switches the contactors to disconnect the system from the grid if it detects a condition consistent with a lost grid connection. It is a dual-channel, one-fault-proof design with feedback contacts that monitor the connected contactors, and it ships with trip thresholds pre-set to common grid codes such as VDE-AR-N 4105\/4110, G98 and G99, which can be adjusted and sealed by a qualified installer to suit local requirements.\u003c\/p\u003e\n\u003cp\u003eSome Distribution Network Service Providers require certified external hardware anti-islanding protection in addition to, or instead of, an inverter's built-in software anti-islanding for larger grid-connected systems. This box provides the relay, contactors and breaker as a single ready-to-mount unit rather than requiring each component to be sourced and wired separately. Always confirm the specific requirements of your local network operator before design and installation.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eZiehl UFR1001E voltage and frequency relay\u003c\/strong\u003e, dual-channel and one-fault-proof, with adjustable trip thresholds pre-set to common grid codes (VDE-AR-N 4105\/4110, G98, G99 and others)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo in-line contactors and a main circuit breaker\u003c\/strong\u003e, pre-wired inside the enclosure\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e63A per phase\u003c\/strong\u003e, suitable for single-phase or three-phase systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP65 enclosure\u003c\/strong\u003e for protection against dust and low-pressure water jets\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFeedback-contact monitoring\u003c\/strong\u003e of the connected contactors, with automatic restart attempts if a switch fails to close\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eVictron Part Number\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eRCD000300200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCurrent Rating\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e63A per phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003ePhases\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eSingle-phase or three-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eContents\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eZiehl UFR1001E relay, 2x in-line contactors, main circuit breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEnclosure Protection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eRelay Voltage Monitoring Range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eAC 15-520V phase-neutral \/ AC 15-530V phase-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eRelay Frequency Setting Range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e45.00-65.00Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eRelay Switching Delay\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eAdjustable 0.05-300s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eRelay Standards\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eVDE-AR-N 4105:2018-11, VDE-AR-N 4110:2018-11, G98, G99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEnclosure Dimensions (W x H x D)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eapprox. 449.5 x 278.8 x 147.9mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":53941333459227,"sku":"VIC-RCD000300200","price":1774.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/victron-63a-anti-islanding-box-vic-rcd000300200-1.webp?v=1789382314","url":"https:\/\/www.nbcampingequipment.com.au\/products\/victron-energy-63a-anti-islanding-box-single-and-three-phase","provider":"NB Camping Equipment","version":"1.0","type":"link"}