{"product_id":"victron-energy-energy-meter-em24-ethernet-3-phase-65a","title":"Victron Energy - Energy Meter - EM24 Ethernet - 3 Phase - 65A","description":"\u003ch2\u003eVictron EM24 Ethernet Energy Meter: 3-Phase Monitoring for ESS, PV and Generator Circuits\u003c\/h2\u003e\n\u003ch3\u003eDirect-Connect 65A Metering with Simple Ethernet Integration\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eVictron EM24 Ethernet\u003c\/strong\u003e is a DIN-rail mounted, three-phase energy meter that measures the power and energy of a 3-phase circuit and reports it straight to a Victron GX device and the VRM Portal. Rated for direct connection up to \u003cstrong\u003e65A per phase\u003c\/strong\u003e with no current transformers required, it is a straightforward way to add grid, PV inverter, generator or AC load metering to an existing Victron GX-based system.\u003c\/p\u003e\n\u003cp\u003eUnlike Victron's RS485-based meters, the EM24 Ethernet connects using a standard \u003cstrong\u003ewired Ethernet\u003c\/strong\u003e connection to the local network, provided that network allows the GX device to reach it. This avoids running an RS485-to-USB interface cable between the distribution board and the GX device, which is useful where Ethernet infrastructure is already in place. Because it depends on the network being available, Victron notes that if the network fails, the system will switch to idle (passthrough) mode until communication is restored.\u003c\/p\u003e\n\u003cp\u003eOnce wired in, the meter is configured entirely from the GX device menu: set its \u003cstrong\u003eRole\u003c\/strong\u003e (Grid meter, PV inverter, Generator, or AC load) and Phase type, and leave the front selector switch on the meter itself unlocked so the GX device can configure it automatically. The meter's own LCD display continues to show local kWh, kW and demand readings.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree-phase, direct-connect metering up to 65A per phase\u003c\/strong\u003e, no current transformers required\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWired Ethernet connection\u003c\/strong\u003e to a local network reachable by the GX device, instead of an RS485-to-USB interface\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFour configurable roles\u003c\/strong\u003e: grid meter (for ESS control), PV inverter output, AC genset output, or dedicated AC load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in LCD display\u003c\/strong\u003e with DIN-rail mounting for standard distribution board installation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVRM Portal integration\u003c\/strong\u003e via a Cerbo GX, Ekrano GX or other compatible GX device\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSingle-Function, Three-Phase Design\u003c\/h3\u003e\n\u003cp\u003eThe EM24 Ethernet is a single-function meter: it is assigned one role at a time across all three phases. Victron advises that installations needing to measure two different things at once, such as the grid on one phase and a single-phase PV inverter on another, should use the EM540 or ET340, or two single-phase meters, instead. For a single dedicated three-phase measurement point, such as the main grid connection or a three-phase PV inverter, the EM24 Ethernet's network connectivity offers a simple alternative to wiring an RS485 run back to the GX device.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eVictron Part Number\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eREL200200100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003ePhases\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMax Current Rating\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e65A per phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMeasurement Type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eDirect\/Shunt (no CTs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eCommunication\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEthernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eRefresh Rate\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e600ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDisplay\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eLCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eConfigurable Roles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eGrid meter, PV inverter, AC genset, AC load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDual-Function Support\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eNo (single role only; use EM540\/ET340 for dual-function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eDIN-rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":53941333393691,"sku":"VIC-REL200200100","price":144.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/victron-em24-3-phase-ethernet-energy-meter-vic-rel200200100.webp?v=1789382388","url":"https:\/\/www.nbcampingequipment.com.au\/products\/victron-energy-energy-meter-em24-ethernet-3-phase-65a","provider":"NB Camping Equipment","version":"1.0","type":"link"}