{"product_id":"victron-isolation-transformer-2000w-115-230v","title":"Victron Energy - 115\/230V 2000W - Isolation Transformer","description":"\u003ch2\u003eVictron 2000W Isolation Transformer: Complete Marine Electrical Safety\u003c\/h2\u003e\n\u003cp\u003eConnecting your vessel to shore power introduces significant electrical challenges, primarily galvanic corrosion and grounding safety risks. The \u003cstrong\u003eVictron 2000W 115\/230V Isolation Transformer\u003c\/strong\u003e eliminates electrical continuity between AC shore power and your boat. By completely isolating your vessel from the shore ground, this system provides absolute protection against galvanic corrosion while ensuring that your onboard safety devices function correctly.\u003c\/p\u003e\n\u003ch3\u003ePrevent Galvanic Corrosion and Protect Your Hull\u003c\/h3\u003e\n\u003cp\u003eGalvanic corrosion occurs when two dissimilar metals are in electrical contact and exposed to a conductive fluid, such as seawater or freshwater. When a boat is connected to shore power, the shore earth wire connects the underwater metals of your boat to other boats and shore structures. This shared connection rapidly accelerates galvanic corrosion, dissolving sacrificial anodes prematurely and attacking vital metal components like your hull, propeller, and shaft.\u003c\/p\u003e\n\u003cp\u003eWhile some marine setups rely on simple galvanic isolators, these do not provide true electrical separation. The Victron Isolation Transformer physically separates the shore power from your onboard system. The shore supply feeds the primary side of the transformer, and your vessel is powered entirely by the secondary side. This breaks the earth circuit completely, stopping galvanic corrosion at the source without compromising electrical safety.\u003c\/p\u003e\n\u003ch3\u003eEnsure Critical Grounding Safety\u003c\/h3\u003e\n\u003cp\u003eA common but highly dangerous workaround to stop galvanic corrosion is disconnecting the shore ground wire. If a short circuit occurs without a proper ground connection, safety devices like a Ground Fault Current Interrupter (GFCI) or Residual Current Device (RCD) will fail to trip, leading to severe electrical hazards.\u003c\/p\u003e\n\u003cp\u003eThis isolation transformer solves the problem by creating a safe, isolated neutral-to-earth bond on the secondary side of the transformer. By connecting all metal parts of your boat to this secondary neutral output, any short circuit will immediately trigger your GFCI or blow a fuse, keeping the vessel and its occupants completely safe. It also eliminates the need for complex polarity alarms.\u003c\/p\u003e\n\u003ch3\u003eBuilt-In Soft Start Technology\u003c\/h3\u003e\n\u003cp\u003eHigh-capacity transformers typically draw a massive inrush current when first connected, which can easily trip sensitive shore power circuit breakers. To counter this, Victron Energy has integrated an intelligent soft start feature into this model. The soft start system manages the initial power draw, ensuring a smooth connection to the shore supply without nuisance breaker trips, regardless of the marina's power quality.\u003c\/p\u003e\n\u003ch3\u003eDurable Hardware for Marine Environments\u003c\/h3\u003e\n\u003cp\u003eDesigned specifically for demanding marine and off-grid environments, the unit is housed in a robust enclosure featuring the distinctive Victron Blue Power branding. It includes built-in recessed handles on the sides for secure manual lifting and positioning during installation. Protective black cable glands provide secure, strain-relieved electrical connections, preventing moisture ingress and ensuring long-term reliability in harsh coastal conditions.\u003c\/p\u003e\n\u003ch3\u003eKey Features and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal Electrical Isolation:\u003c\/strong\u003e Completely separates shore power from the vessel supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCorrosion Prevention:\u003c\/strong\u003e Eliminates the earth loop that causes severe galvanic corrosion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnhanced Safety:\u003c\/strong\u003e Ensures proper operation of onboard RCDs, GFCIs, and fuses.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoft Start Protection:\u003c\/strong\u003e Prevents shore power breakers from tripping due to high inrush currents.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Voltage Handling:\u003c\/strong\u003e Engineered to support both 115V and 230V configurations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine-Grade Construction:\u003c\/strong\u003e Durable enclosure with recessed lifting handles and secure cable glands.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProtect Your Investment Today\u003c\/h3\u003e\n\u003cp\u003eUpgrading to a true isolation transformer is the most effective method to safeguard your hull from corrosion and protect your electrical system from grounding faults. Equip your marine electrical system with the Victron 2000W 115\/230V Isolation Transformer to ensure reliable, safe shore power connectivity wherever you dock.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003ePower Rating\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e2000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eAC Input Voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e115 or 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eAC Output Voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e120 or 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eFrequency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOutput Current Rating\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e17 A (115 V); 8.5 A (230 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eSoft Start\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOperating Temperature Range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-20 °C to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eHumidity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eMax 95%, Non-Condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eTransformer Type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eToroidal (Low Noise, Low Weight), 1:1.05 Ratio\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEnclosure\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eAluminium (Blue RAL 5012)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eProtection Category\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eIP21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eSafety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN 60076\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e12.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eDimensions (H x W x D)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e375 x 214 x 135 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMinimal Cable Cross-Sections\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e115 V: 2.5 mm² (AWG 13); 230 V: 1.5 mm² (AWG 16)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eModel Code\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eITR040202041\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364368773403,"sku":"VIC-ITR040202041","price":599.95,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/VIC-ITR040202041-01.jpg?v=1781658052","url":"https:\/\/www.nbcampingequipment.com.au\/products\/victron-isolation-transformer-2000w-115-230v","provider":"NB Camping Equipment","version":"1.0","type":"link"}