{"product_id":"victron-lynx-smart-bms-1000-m10","title":"Victron Energy - Lynx Smart BMS 1000 M10","description":"\u003ch2\u003eVictron Lynx Smart BMS 1000 M10: Advanced Battery Management for High-Capacity Lithium Systems\u003c\/h2\u003e\n\u003ch3\u003eIntegrated Protection and Control for 12V, 24V, and 48V Victron Lithium Smart Battery Banks\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eVictron Lynx Smart BMS 1000 M10\u003c\/strong\u003e is a dedicated \u003cstrong\u003ebattery management system\u003c\/strong\u003e engineered for \u003cstrong\u003eVictron Lithium Battery Smart\u003c\/strong\u003e series (LiFePO4). It provides comprehensive protection, monitoring, and control for large-scale energy storage, making it an essential component for demanding off-grid, marine, and mobile applications. This unit is designed to manage battery banks up to 84 kWh in 12V systems and 102 kWh in 24V and 48V configurations, supporting up to 20 batteries in series, parallel, or series\/parallel arrangements.\u003c\/p\u003e\n\u003cp\u003eUnlike generic BMS solutions, the Lynx Smart BMS integrates a high-current contactor, pre-charge circuit, and advanced communication protocols into a single, modular unit. This reduces installation complexity, eliminates the need for external pre-charge resistors, and enhances system reliability. The built-in 1000 A continuous contactor serves as both a primary safety disconnect and a remote-controllable main switch, while the pre-charge circuit mitigates inrush currents that can damage inverters and chargers.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e1000 A continuous contactor\u003c\/strong\u003e with 1200 A peak rating for 5 minutes, ensuring safe disconnection under heavy loads\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated pre-charge circuit\u003c\/strong\u003e prevents high inrush currents, protecting downstream electronics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBluetooth monitoring and control\u003c\/strong\u003e via VictronConnect app for real-time state of charge, voltage, current, and alarms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVE.Can and NMEA 2000 communication\u003c\/strong\u003e for seamless integration with GX devices (e.g., Cerbo GX) and marine MFDs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuse monitoring for up to four Lynx Distributors\u003c\/strong\u003e, providing alerts for blown fuses via VictronConnect or VRM Portal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgrammable relay\u003c\/strong\u003e for alarm or alternator field control, with Alternator ATC mode for safe alternator shutdown\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAUX output (1.1 A)\u003c\/strong\u003e to power critical loads like a GX device after a low-voltage disconnect\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstant readout\u003c\/strong\u003e of key parameters without connecting to the BMS, enabling quick diagnostics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvanced System Integration and Safety\u003c\/h3\u003e\n\u003cp\u003eThe Lynx Smart BMS works in concert with Victron inverter\/chargers and solar chargers through a connected GX device and DVCC (Distributed Voltage and Current Control). This enables automatic charge and discharge control based on cell-level data, optimising battery health and longevity. The ATC (Allow-to-Charge) and ATD (Allow-to-Discharge) contacts provide direct control over third-party chargers and loads with remote on\/off ports, expanding compatibility beyond Victron equipment.\u003c\/p\u003e\n\u003cp\u003eFor marine installations, the VE.Can interface uses standard RJ45 cables and supports NMEA 2000 (and J1939) protocols, allowing battery data to be displayed on multifunction displays. A VE.Can to NMEA 2000 micro-C male cable is required for direct connection. The system also monitors up to four Lynx Distributor modules via RJ10 connections, reporting individual fuse status and triggering alarms if a fuse blows, which is critical for maintaining uptime in remote or unattended systems.\u003c\/p\u003e\n\u003ch3\u003eRobust Construction for Demanding Environments\u003c\/h3\u003e\n\u003cp\u003eHoused in an IP22-rated ABS enclosure, the Lynx Smart BMS 1000 M10 features tinned copper busbars (8 x 30 mm) with M10 stud terminals (torque: 33 Nm, or 17 Nm for earlier serial numbers). These heavy-duty connections accommodate large-gauge cables, ensuring minimal voltage drop at high currents. The unit operates reliably in temperatures from -40 °C to +60 °C and withstands up to 95% non-condensing humidity, making it suitable for engine rooms, outdoor enclosures, and mobile installations.\u003c\/p\u003e\n\u003ch3\u003eWhy Choose the Lynx Smart BMS Over Generic Alternatives?\u003c\/h3\u003e\n\u003cp\u003eStandard BMS units often lack integrated contactors, requiring external relays and complex wiring that increase failure points. The Lynx Smart BMS consolidates these functions, reducing installation time and potential faults. Its pre-charge circuit eliminates the need for manual pre-charge procedures, which can be hazardous and inconvenient. Additionally, the seamless integration with Victron's ecosystem provides a unified monitoring experience, from the battery to the inverter, through a single interface.\u003c\/p\u003e\n\u003cp\u003eFor system builders, the ability to monitor fuse status remotely reduces troubleshooting time and prevents unexpected downtime. The programmable relay adds flexibility for alternator control, ensuring that the alternator is disconnected before the battery in a fault condition, protecting both the alternator and the electrical system.\u003c\/p\u003e\n\u003ch3\u003eTake Control of Your Energy System\u003c\/h3\u003e\n\u003cp\u003eUpgrade your Victron Lithium Smart battery bank with the Lynx Smart BMS 1000 M10 for reliable, integrated protection and monitoring. Whether you're powering a remote off-grid cabin, a marine vessel, or a mobile workshop, this BMS delivers the safety and data you need to maximise performance and lifespan. Add to your system today and experience the confidence of professional-grade battery management.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eLynx Smart BMS\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e1000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eBattery voltage range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e9 – 60 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum input voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e75 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eSupported system voltages\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e12, 24 or 48 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eReverse polarity protection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMain safety contactor continuous current rating\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e1000 A continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMain safety contactor peak current rating\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e1200 A for 5 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003ePower consumption OFF mode\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e0.3 mA for all system voltages\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003ePower consumption in Standby mode\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eApproximately 0.6 W (50 mA at 12 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003ePower consumption in ON mode\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eApproximately 4.2 W (350 mA at 12 V) depending on the state of the relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMinimum load resistance for pre-charging\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e10 Ω and above for 12 V systems 20 Ω and above for 24 V and 48 V systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eAUX output maximum current rating\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e1.1 A continuous, protected by resettable fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eAllow-to-charge port Maximum current rating\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e0.5 A at 60 VDC, protected by resettable fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eAllow-to-discharge port Maximum current rating\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e0.5 A at 60VDC, protected by resettable fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eAlarm relay (SPDT) Maximum current rating\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e2 A at 60 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eBusbar\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eM10 (Torque: 33 Nm) (17 Nm for units with a serial number before HQ2340XXXX)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eVE.Can\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eRJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eI\/O\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eRemovable multi-connector with screw terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eBattery BTV cables\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eMale and female circular 3-pole connector with M8 screw ring Up to 20 batteries can be connected in one system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eLynx Distributor fuse monitoring (up to 4 modules)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eRJ10 (cable ships with each Lynx Distributor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEnclosure material\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eABS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEnclosure dimensions (h x w x d)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e230 x 180 x 100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnit weight\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e2.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eBusbar material\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eTinned copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eBusbar dimensions (h x w)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e8 x 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-40 °C to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStorage temperature range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-40 °C to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eHumidity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eMax. 95 % (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eProtection class\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eIP22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eSafety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN-IEC 63000:2018\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEMC\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN-IEC 61000-6-3:2007\/A1:2011\/AC:2012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eQMS\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eNEN-EN-ISO 9001:2015\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364371034395,"sku":"VIC-LYN034170210","price":1349.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/VIC-LYN034170210-01.jpg?v=1781658055","url":"https:\/\/www.nbcampingequipment.com.au\/products\/victron-lynx-smart-bms-1000-m10","provider":"NB Camping Equipment","version":"1.0","type":"link"}