{"product_id":"victron-lynx-smart-bms-1000-ng-m10","title":"Victron Energy - Lynx Smart BMS 1000 NG (NextGen) M10","description":"\u003ch2\u003eNext-Generation Battery Management for High-Capacity Lithium Systems\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eVictron Lynx Smart BMS 1000 NG\u003c\/strong\u003e (NextGen) stands as the ultimate command centre for your energy storage, specifically engineered to integrate seamlessly with Victron Lithium Battery Smart models. Designed for complex power setups in marine vessels, off-grid properties, and high-demand industrial applications, this advanced Battery Management System ensures your 12V, 24V, or 48V lithium iron phosphate (LiFePO4) battery banks operate safely and efficiently.\u003c\/p\u003e\n\u003cp\u003eUnlike standard controllers, the Lynx Smart BMS goes beyond simple cell balancing. It actively protects your power system from deep discharges, overcharging, and extreme temperatures, prolonging the lifespan of your heavy-duty battery arrays. With a robust 1000A continuous current rating and surge capabilities up to 1200A for five minutes, it easily handles the high loads of demanding inverter networks and parallel configurations.\u003c\/p\u003e\n\u003ch3\u003eIntegrated Pre-Charge Circuit and Primary Safety Contactor\u003c\/h3\u003e\n\u003cp\u003eOne of the most critical challenges when powering up high-capacity inverter systems is managing the initial rush of electrical current. The integrated pre-charge circuit resolves this completely. By safely charging the internal capacitors of connected inverters before the main contactor engages, it prevents damaging inrush currents that can degrade components over time. This eliminates the need for manual pre-charging steps or external resistors, reducing installation complexity and lowering the risk of hardware faults.\u003c\/p\u003e\n\u003cp\u003eAdditionally, the built-in safety contactor acts as a dependable secondary safety mechanism. It provides an immediate physical disconnect in the event of a critical system fault, isolating your batteries to prevent severe damage. This contactor can also be controlled remotely, giving users the ability to manually shut down the system during maintenance or long-term storage.\u003c\/p\u003e\n\u003ch3\u003eParallel Redundancy for Mission-Critical Power\u003c\/h3\u003e\n\u003cp\u003eThe \"NG\" NextGen series introduces a highly requested feature for complex electrical architectures: parallel redundancy. By installing multiple Lynx Smart BMS units in parallel, system builders can drastically increase overall storage capacity while establishing a failsafe network. In the event of an isolated communication or hardware issue, the redundant architecture allows your system to maintain safe, continuous operation. This ensures your off-grid home or commercial marine vessel never experiences an unexpected total power loss.\u003c\/p\u003e\n\u003ch3\u003eComprehensive Monitoring and System Integration\u003c\/h3\u003e\n\u003cp\u003eFull visibility into your power usage is crucial for long-term reliability. Equipped with built-in Bluetooth, this Victron BMS allows installers and end-users to monitor real-time battery voltage, temperature data, and system health directly from a smartphone or tablet using the VictronConnect app.\u003c\/p\u003e\n\u003cp\u003eFor more advanced setups, the included VE.Can port allows direct communication with Victron GX devices, such as the Cerbo GX. This enables global remote monitoring via the VRM portal. Furthermore, native NMEA 2000 compatibility ensures the system integrates flawlessly into modern marine networks, displaying crucial energy metrics right on your glass bridge or multi-function display.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Current Capacity:\u003c\/strong\u003e 1000A continuous current rating via heavy-duty M10 tinned copper busbars.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in Pre-Charge:\u003c\/strong\u003e Protects inverter capacitors by safely managing inrush currents during startup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Safety Contactor:\u003c\/strong\u003e Reliable hardware disconnect for critical faults and remote system isolation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eParallel Redundancy:\u003c\/strong\u003e Connect multiple NextGen BMS units for scalable capacity and fault-tolerant continuous operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Diagnostics:\u003c\/strong\u003e Built-in Bluetooth and VE.Can connectivity for local and remote VictronConnect monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Voltage Support:\u003c\/strong\u003e Fully compatible with 12V, 24V, and 48V Victron Lithium Smart battery configurations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSecure the core of your energy infrastructure with robust protection and intelligent control. Upgrade your off-grid or marine electrical architecture with the Victron Lynx Smart BMS 1000 NG and maintain complete visibility over your power reserves today.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"product-specifications\" style=\"width:100%; border-collapse:collapse; border:1px solid #d9d9d9; table-layout:auto;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eLynx Smart BMS\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e1000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eBattery voltage range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e9 – 60 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMaximum input voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e75 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eSupported system voltages\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e12, 24 or 48 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eReverse polarity protection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMain safety contactor continuous current rating\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e1000 A continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMain safety contactor peak current rating\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e1200 A for 5 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003ePower consumption OFF mode\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e0.3 mA for all system voltages\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003ePower consumption in Standby mode\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eApproximately 0.6 W (50 mA at 12 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003ePower consumption in ON mode\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eApproximately 4.2 W (350 mA at 12 V) depending on the state of the relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eMinimum load resistance for pre-charging\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e10 Ω and above for 12 V systems 20 Ω and above for 24 V and 48 V systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eAUX output maximum current rating\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e1.1 A continuous, protected by resettable fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eAllow-to-charge port Maximum current rating\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e0.5 A at 60 VDC, protected by resettable fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eAllow-to-discharge port Maximum current rating\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e0.5 A at 60VDC, protected by resettable fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eAlarm relay (SPDT) Maximum current rating\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e2 A at 60 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eBusbar\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eM10 (Torque: 33 Nm) (17 Nm for units with a serial number before HQ2340XXXX)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eVE.Can\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eRJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eI\/O\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eRemovable multi-connector with screw terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eBattery BTV cables\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eMale and female circular 3-pole connector with M8 screw ring Up to 20 batteries can be connected in one system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eLynx Distributor fuse monitoring (up to 4 modules)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eRJ10 (cable ships with each Lynx Distributor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEnclosure material\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eABS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEnclosure dimensions (h x w x d)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e230 x 180 x 100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eUnit weight\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e2.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eBusbar material\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eTinned copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eBusbar dimensions (h x w)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e8 x 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-40 °C to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eStorage temperature range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003e-40 °C to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eHumidity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eMax. 95 % (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eProtection class\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eIP22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eSafety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN-IEC 63000:2018\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eEMC\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eEN-IEC 61000-6-3:2007\/A1:2011\/AC:2012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9; padding:8px; text-align:left; width:35%; vertical-align:top;\"\u003eQMS\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:8px; vertical-align:top;\"\u003eNEN-EN-ISO 9001:2015\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":52364371493147,"sku":"VIC-LYN034170310","price":2119.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/3354\/9083\/files\/VIC-LYN034170310-01.jpg?v=1781658056","url":"https:\/\/www.nbcampingequipment.com.au\/products\/victron-lynx-smart-bms-1000-ng-m10","provider":"NB Camping Equipment","version":"1.0","type":"link"}