Most people swap the battery and stop there, but the battery's the easy part. Every charger that feeds it needs a lithium setting: the mains charger, the DC-DC and the solar controller. This one goes through each, with the makers' own settings (Victron, Renogy, Exotronic, Enerdrive), then the isolator and the battery monitor.
Read the guide: Switching to lithium: what else has to change?
Watch on YouTube · Subscribe to the channel
Chapters
- 0:00 Intro
- 0:28 Your battery maker's numbers
- 0:57 The mains charger
- 1:17 The DC-DC charger
- 1:42 The solar controller
- 2:00 The VSR or isolator
- 2:21 The battery monitor
- 2:44 The full checklist
The parts
Grouped by type: Batteries.
Sources
- Victron Energy, Lithium Smart Battery manual (rev 21): victronenergy.com
- Renogy, Core Mini 12.8V 100Ah user manual: renogy.com
- Exotronic, 12V 100Ah Alpha Slimline product page: exotronic.com.au
- Victron Energy, Blue Smart IP65 Charger manual: victronenergy.com
- Victron Energy, Smart IP43 Charger manual: victronenergy.com
- Enerdrive, 12V 40A AC Battery Charger page: enerdrive.com.au
- Enerdrive, DC-DC+ Battery Charger Owners Manual (Rev 2.05), p. 38
- Victron Energy, Orion XS 12/12-50A manual: victronenergy.com
- Renogy, 12V 30A/50A DC-DC charger with MPPT manual: au.renogy.com
- Victron Energy, SmartSolar MPPT 100/30 & 100/50 manual: victronenergy.com
- Victron Energy, BlueSolar PWM LCD&USB manual: victronenergy.com
- Victron Energy, Cyrix Li-ion 120 A datasheet: victronenergy.com
- Victron Energy, SmartShunt manual (Rev 19): victronenergy.com
Sources read 16 October 2026.
Victron's SmartSolar manual gives the LiFePO4 float as 13.5V in one place and 13.2V in another; your battery maker's figure wins. Check the manual for your own gear.
Voiceover is AI; script and facts checked by NB Camping Equipment.
Transcript
Intro
G'day. In this one: the numbers your battery's maker asks for, then the mains charger, the DC-DC, the solar controller, your isolator, and the battery monitor. Let's get into it. Most people swap the battery and stop there. The battery's the easy part. Every charger that feeds it needs a lithium setting: mains, DC-DC and solar. Then reset the monitor.
Your battery maker's numbers
Victron: use a charger profile that "matches the battery chemistry (LiFePO4)". Renogy: only a charger "compatible with lithium iron phosphate". Exotronic's warranty doesn't cover an "improper voltage setting on a charger". Their numbers differ. Victron Lithium Smart: 14.2 V, float 13.5 V. Renogy Core Mini: 14.4 V. Exotronic Alpha: 14.0 to 14.2 V, float 13.5 V.
The mains charger
Most modern chargers have a lithium mode. You have to pick it. Victron Blue Smart IP65: Li-ion mode, 14.2 V, no float. Enerdrive ePOWER: Lithium, with your own voltage. Its factory default is Flooded. No lithium or custom setting? That's the one to replace.
The DC-DC charger
Victron Orion: the lithium preset. Renogy DC-DC: ships on SLA, turn the knob to Li. Enerdrive: "consult the battery manufacturer". It matters more with lithium. Victron: lithium takes a big current, so care is needed not to overload the alternator. A DC-DC is one fix.
The solar controller
Victron SmartSolar: the LiFePO4 preset, 14.2 V for 2 hours. Victron's manual gives the float as 13.5 V in one table and 13.2 V in another: use your battery maker's. A basic PWM controller with no battery-type setting is the most common thing to replace.
The VSR or isolator
A plain VSR joins the batteries when the voltage is up. The lithium then charges straight off the alternator, nothing limiting the current. Victron's Cyrix-Li-ct only joins when the lithium's BMS says it's OK. For most 4WDs, a DC-DC is the simpler answer.
The battery monitor
A shunt set up for AGM reads lithium wrong. SmartShunt: Peukert 1.05, charge efficiency 99%, charged voltage 0.2 to 0.3 V below float, and the new Ah. And don't leave lithium flat. Victron: 10 mA can damage a 200 Ah battery left discharged for more than 8 days.
The full checklist
The full checklist, with every maker's settings: nbcampingequipment.com.au