Victron
Victron Energy - 48V - 4500W - MultiPlus-II 48/4k5/55-32 GX - Inverter/Charger
Victron Energy - 48V - 4500W - MultiPlus-II 48/4k5/55-32 GX - Inverter/Charger
Couldn't load pickup availability
Victron MultiPlus-II GX: Integrated Inverter/Charger with Built-in Monitoring for 48V Systems
Professional-Grade Power Conversion with Advanced Energy Management
The Victron MultiPlus-II GX combines a pure sine wave inverter, adaptive battery charger, and automatic transfer switch in a single compact unit, now with an integrated GX controller for local and remote system oversight. Designed for demanding off-grid, backup, and hybrid energy applications, it delivers reliable AC power from a 48V battery bank while intelligently managing grid or generator input. With PowerControl and PowerAssist technology, the unit prevents AC source overload by automatically reducing charge current or supplementing shore power with battery energy during peak demand, making it ideal for installations with limited supply capacity.
Engineered for Australian conditions, the MultiPlus-II GX operates across a wide temperature range from -40°C to +65°C with fan-assisted cooling, ensuring consistent performance in harsh environments. Its high-frequency design achieves up to 95% maximum efficiency, minimising energy loss and reducing heat buildup in confined spaces such as vehicle compartments or equipment rooms.
Built-in GX Controller for Seamless Monitoring and Control
Unlike standard inverter/chargers that require external monitoring hardware, the MultiPlus-II GX features an integrated GX device with a backlit LCD display, Ethernet, Wi-Fi, and VE.Direct connectivity. This allows direct access to Victron's VRM portal for real-time performance tracking, remote firmware updates, and automated alerts without additional components. The built-in Battery Monitor function enables autonomous system operation based on voltage, load, or state of charge, while programmable relays and digital inputs support custom automation sequences such as generator start/stop or load shedding.
Uninterrupted Power with Dual AC Outputs
Two AC outputs provide intelligent load management: the primary output supplies continuous power to critical loads with a near-instantaneous transfer time, while the auxiliary output can disconnect non-essential loads when operating on battery power alone. This configuration allows high-consumption devices like water heaters to run only when grid or generator power is available, preserving battery capacity for essential equipment.
Adaptive Charging for Maximum Battery Life
The integrated charger supports lithium, lead-acid, and other battery chemistries with adaptive 4-stage charging, temperature compensation, and BatterySafe mode to prevent over-gassing. Lithium batteries are integrated via BMS-Can or SmallBMS interfaces for precise charge control and cell-level protection. Storage mode reduces float voltage to minimise self-discharge during extended periods of inactivity, extending overall battery service life.
Scalable Architecture for Growing Energy Demands
The MultiPlus-II GX supports parallel and three-phase configurations, allowing multiple units to be combined for higher output or split-phase operation. This scalability makes it suitable for everything from single-phase off-grid cabins to large commercial backup systems. VE.Bus communication ensures synchronised operation and centralised monitoring across all connected units.
Key Features
- Integrated GX controller with LCD display, Ethernet, Wi-Fi, and VRM portal access
- PowerControl and PowerAssist prevent AC source overload and supplement limited grid/generator input
- Dual AC outputs with programmable load management for critical and non-essential circuits
- Adaptive 4-stage charger compatible with lithium, lead-acid, and other battery types
- Parallel and three-phase capable for scalable system design
- Wide operating temperature range (-40°C to +65°C) with fan-assisted cooling
- Programmable relay and digital inputs for custom automation and generator start/stop
- IP21 steel enclosure with M8 battery connections and 13mm² AC terminals
Applications
- Off-grid homes and cabins requiring reliable 230V AC power from 48V battery banks
- Marine and RV installations with limited shore power capacity
- Hybrid solar and battery storage systems with grid export and backup capability
- Backup power for critical equipment in commercial or industrial settings
- Remote telecommunications and monitoring sites needing autonomous operation
Peak power of 7 kW for 1 minute handles motor starting surges and short-term overloads without tripping.
Charge current of 55 A at 25°C enables rapid recharging of large battery banks, reducing generator run time in off-grid scenarios.
Experience the reliability and intelligence of Victron's integrated power solution. Configure your MultiPlus-II GX today for uninterrupted energy management wherever you need it.
Specifications
| PowerControl & PowerAssist | Yes |
|---|---|
| Transfer switch | 32 A |
| Maximum AC input current | 32 A |
| DC Input voltage range | 38 – 60 V |
| Output | 230V ± 2% 50 Hz ± 0.1% (1) |
| Cont. output power at 25 °C | 4 kW |
| Cont. output power at 40 °C | 3.7 kW |
| Cont. output power at 65 °C | 3 kW |
| Time-limited power 1 (cold start) | 4.5 kW/2h |
| Time-limited power 2 (cold start) | 6 kW/25min |
| Max apparent feedin power | 4 kW |
| Peak power | 7 kW/1min |
| Maximum efficiency | 95% |
| Zero load power | 20 W |
| Zero load power in AES mode | 13 W |
| Zero load power in Search mode | 8 W |
| AC Input voltage range | 187-265 V |
| AC Input frequency range | 45 – 65 Hz |
| Charge voltage 'absorption' | 57.6 V |
| Charge voltage 'float' | 55.2 V |
| Storage mode | 52.8 V |
| Max. battery charge current at 25 °C | 55 A |
| Max. battery charge current at 40 °C | 50 A |
| Battery temperature sensor | Yes |
| Compatible battery chemistries | Lithium, Lead-acid, Zinc-Bromine and more (3) |
| Auxiliary output | Yes (32A) |
| Interfaces | BMS-Can, USB, Ethernet, VE.Direct, Wi-Fi |
| External AC current sensor (optional) | 50 A or 100 A |
| Programmable relay (4) | Yes |
| Protection (2) | a-g |
| VE.Bus communication port | For parallel and three-phase operation, remote monitoring and system integration |
| General-purpose communication port | Yes, 2x |
| Remote on-off | Yes |
| Operating temperature range | -40 to +65 °C (fan-assisted cooling) |
| Maximum humidity (non-condensing) | 95% |
| Maximum altitude | 2000 m |
| Material & Colour | Steel, blue RAL 5012 |
| Protection category | IP21 |
| Battery-connection | M8 bolts |
| 230 VAC connection | Screw terminals 13 mm² (6 AWG) |
| Weight | 21.4kg |
| Dimensions (hxwxd) | 590 x 275 x 149 mm |
| Safety | EN-IEC 60335-1, EN-IEC 60335-2-29, EN-IEC 62109-1, EN-IEC 62109-2 |
| Emission, Immunity | EN 55014-1, EN 55014-2 EN-IEC 61000-3-2, EN-IEC 61000-3-3 IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3 |
| Uninterruptible power supply | Certification pending |
| Anti-islanding | Certification pending |
Share